background image

 

Part No. 119557-A Rev. 00
February 1998

 
  

 
 

Using the Model 5782 
ATM Virtual Network 
Router

Содержание 5782

Страница 1: ...Part No 119557 A Rev 00 February 1998 Using the Model 5782 ATM Virtual Network Router ...

Страница 2: ... proprietary to Bay Networks Inc Trademarks Optivity PPX and Bay Networks are registered trademarks and Centillion Expanded View EZ Install EZ Internetwork EZ LAN IP AutoLearn Network Atlas OmniView PathMan RouterMan SpeedView System 5000 Threshold Manager and the Bay Networks logo are trademarks of Bay Networks Inc All other trademarks and registered trademarks are the property of their respectiv...

Страница 3: ...Bay Networks product or system name is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class A CISPR 22 Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropri...

Страница 4: ...Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Notice For equipment using loopstart lines please note that the Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termin...

Страница 5: ...g format 04DU9 DN 1 544 MB D4 framing format with B8ZF coding 04DU9 1KN 1 544 MB ESF framing format 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding 04DU9 1ZN 1 544 MB ANSI ESF and ZBTSI without line power The telephone company will select the code it has available The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ48C When you request 56K 64K Service you...

Страница 6: ...d in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License Grant Bay Networks Inc Bay Networks grants the end user of the Software Licensee a personal nonexclusive nontransferable license a to use the Software either on a single computer or if applicable on a single authorized device identified by host ID for which it was originally acq...

Страница 7: ... responsible for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files data or programs 4 Limitation of liability IN NO EVENT WILL BAY NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM INACCURATE OR L...

Страница 8: ...re or related technical data or information to any military end user or for any military end use including the design development or production of any chemical nuclear or biological weapons 9 General If any provision of this Agreement is held to be invalid or unenforceable by a court of competent jurisdiction the remainder of the provisions of this Agreement shall remain in full force and effect T...

Страница 9: ... the Model 5782 VNR 1 2 Configuring the VNR 1 5 SpeedView Application 1 5 Command Line Interface 1 5 Site Manager Application 1 6 Model 5782 VNR Features 1 6 Supported Protocols 1 7 LAN Emulation 1 8 ATM Q 2931 Signaling 1 8 Data Encapsulation 1 9 Simulated Multicast Packet Support 1 10 ARP and Inverse ARP Support 1 10 About the Model 5000BH Backplane 1 11 Centillion Architecture 1 11 PPX Router B...

Страница 10: ...ng the Installation 2 10 Removing and Replacing the Router 2 11 Removing the VNR 2 11 Installing the Replacement VNR 2 12 Removing the Flash Memory Card 2 13 Protecting the Files on the Flash Memory Card 2 14 Upgrading Memory 2 15 Chapter 3 Starting the Model 5782 VNR Configuring the MCP 3 2 Accessing the Model 5782 VNR over ATM 3 2 Connecting a Terminal to the Model 5000BH Chassis Service Port 3 ...

Страница 11: ...cations A 2 Memory A 2 Backplane Interface Data Rates A 2 Electrical Specifications A 2 Electromagnetic Emissions A 3 Environmental Specifications A 3 Safety Agency Approvals A 3 Appendix B Model 5782 VNR LEDs Appendix C Network Information Worksheet Sample Quick Start Network Setup C 1 Completing the Quick Start ATM Worksheet C 3 Appendix D Sample install bat Scripts ATM PVC Setup Example D 2 LAN...

Страница 12: ......

Страница 13: ...igure 2 4 Inserter Extractor Levers in the Vertical Position 2 7 Figure 2 5 Seating the Module 2 8 Figure 2 6 Airflow Module Orientation 2 9 Figure 2 7 Replacing the Filler Panel 2 10 Figure 2 8 Removing a Module 2 12 Figure 2 9 Removing the Flash Memory Card 2 13 Figure 2 10 Flash Memory Card Read Write Protect Switch 2 14 Figure 3 1 Slot Selection Menu for the Model 5000BH Chassis 3 4 Figure 3 2...

Страница 14: ......

Страница 15: ...d SVCs 1 7 Table 3 1 Service Port Pin Assignments 3 3 Table 3 2 Terminal Console Parameters 3 3 Table 3 3 Quick Start Installation Files 3 8 Table 3 4 Technician Interface Quick Start Commands 3 10 Table B 1 LEDs on the Model 5782 VNR B 2 Table C 1 Quick Start ATM Worksheet C 4 ...

Страница 16: ......

Страница 17: ...ng ip_address you enter ping 192 32 10 12 bold text Indicates text that you need to enter command names and buttons in menu paths Example Enter wfsm Example Use the dinfo command If you want to Go to Understand more about the Model 5782 VNR and its features Chapter 1 Install the Model 5782 VNR Chapter 2 Start the Model 5782 VNR Chapter 3 Review the technical specifications of the Model 5782 VNR Ap...

Страница 18: ...Indicates data that appears on the screen Example Set Bay Networks Trap Monitor Filters separator Separates menu and option names in instructions and internal pin to pin wire connections Example Protocols AppleTalk identifies the AppleTalk option in the Protocols menu Example Pin 7 19 20 vertical line Indicates that you enter only one of the parts of the command The vertical line separates choices...

Страница 19: ...u can now print technical manuals and release notes free directly from the Internet Go to support baynetworks com library tpubs Find the Bay Networks products for which you need documentation Then locate the specific category and model or version for your hardware or software product Using Adobe Acrobat Reader you can open the manuals and release notes search for the sections you need and print th...

Страница 20: ... reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Bay Networks service program call one of the following Bay Networks Technical Solutions Centers Region Telephone number Fax number United States and Canada 800 2LANWAN then enter Express Routing Code ERC 290 when prompted to purchase or renew a service contract 978 916 8880 direct 978 9...

Страница 21: ...tworks products Training programs can take place at your site or at a Bay Networks location For more information about training programs call one of the following numbers Region Telephone number United States and Canada 800 2LANWAN then enter Express Routing Code ERC 282 when prompted 978 916 3460 direct Europe Middle East and Africa 33 4 92 96 15 83 Asia Pacific 61 2 9927 8822 Tokyo and Japan 81 ...

Страница 22: ......

Страница 23: ...twork Router This chapter introduces the Model 5782 ATM Virtual Network Router VNR and includes the following topics Topic Page About the Model 5782 VNR 1 2 Configuring the VNR 1 5 Model 5782 VNR Features 1 6 About the Model 5000BH Backplane 1 11 Hardware Description 1 14 ...

Страница 24: ...ne in a Model 5000BH chassis Model 5724M ATM MCP Switch Host modules that provide ports for ATM connectivity optional In Figure 1 1 a Model 5782 VNR routes data between emulated LANs ELANs 1 2 and 3 through the ATM master control processor MCP external interfaces In this example three ATM MCP ports connect to three separate Centillion 100 switches Each Centillion 100 switch maintains its own ELAN ...

Страница 25: ...vers Token ring Workstations 10BASE T Workstations Local servers GF00001 OC 3 Multimode 155 Mb s Model 5000BH Hub Model 5724M ATM MCP Switch Model 5782 ATM VNR Model 5328 EtherSpeed Switch ATM Campus and WAN Centillion 100 switch OC 3 Multimode 155 Mb s Centillion 100 switch Centillion 100 switch ELAN 1 ELAN 2 ELAN 3 10BASE T Workstations ...

Страница 26: ... the Model 5782 VNR controls access to these ELANs Figure 1 2 Model 5782 VNR in an ATM Network Logical View 100BASE T Token ring 10BASE T GF00002 OC 3 Multimode 155 Mb s Model 5000BH Hub Model 5724M ATM MCP Switch Model 5782 ATM VNR Centillion 100 switch Centillion 100 switch Centillion 100 switch ELAN 1 ELAN 2 ELAN 3 ATM Network Workstation A Workstation B Workstation C ...

Страница 27: ...and monitoring support for an MCP switch module Expanded View OmniView Network Atlas Threshold Manager and other Optivity applications provide comprehensive monitoring and troubleshooting support For additional information about how to configure an MCP switch module see Using SpeedView 3 0 for Windows Command Line Interface The router Technician Interface and the Quick Start installation script pr...

Страница 28: ...ices Model 5782 VNR Features The Model 5782 VNR has the following features Support for Bay Networks Router Software BayRS for multiprotocol routing over ATM ATM Forum compatible LAN emulation LANE for Ethernet and token ring networks ATM Forum UNI Version 3 0 and Version 3 1 signaling protocol for SVCs known as Q 2931 Multiprotocol encapsulation functions that enable concurrent bridging and multip...

Страница 29: ...o a LANE service record with an unspecified emulated LAN type ensure that the protocols you add are supported by the emulated LAN Ethernet or token ring that you want to join Table 1 1 Protocols Supported for Standard PVCs and SVCs PVC Using LLC SNAP NLPID or NULL SVC Using LLC SNAP or NULL RFC 1577 SVC Using LANE 802 3 SVC Using LANE 802 5 Bridge IP Bridge Bridge Spanning Tree RIP Spanning Tree S...

Страница 30: ... signaling protocol for SVCs known as Q 2931 ATM signaling allows the router to dynamically establish maintain and clear a switched virtual connection at the user to network interface UNI The signaling ATM adaptation layer SAAL resides between the ATM layer and Q 2931 Figure 1 3 SAAL is a reliable transport layer for signaling messages sent between peer Q 2931 elements over the ATM layer IPX XNS R...

Страница 31: ... from 2 to 8 octets in length to the PDU to allow decoding The decoding process determines the proper service access point SAP When receiving information the encapsulation method evaluates the header to determine whether the PDU is a valid routed or bridged cell If it is valid the encapsulation method then strips the header from the cell and passes it to the appropriate SAP for routing or bridging...

Страница 32: ...al interface ARP and Inverse ARP Support The Model 5782 VNR supports the Address Resolution Protocol ARP enabling the router to dynamically resolve IP network layer protocol to VPI VCI address mappings ATM learns the PVC address by detecting the PVC that delivered the ARP response ATM also supports the Inverse ARP protocol However you can use Inverse ARP only if both the local and remote routers s...

Страница 33: ...ATM port interfaces however the Model 5000BH chassis backplane can immediately forward both LAN and ATM traffic Model 5782 VNR modules attach to one of two Centillion ATM buses on a Model 5000BH backplane Switching in a Model 5000BH chassis spans 12 of 14 slots Each Centillion ATM bus spans six slots slots 2 through 7 and 8 through 13 The architecture includes several advanced hardware components ...

Страница 34: ...the following functions Performs user to network interface UNI signaling Handles the control functions for LAN emulation LANE clients Provides LANE services LECS LES BUS Handles switch wide housekeeping functions such as network management PPX Router Bus The Parallel Packet Express PPX is a redundant bus with four independent parallel paths that perform at 1 Gb s between router interfaces Model 57...

Страница 35: ...ycled or the module is reset The supervisory module also supports configuration terminal support through the service port on the front panel of the chassis Service Port The service port located on the front panel of the Model 5000BH chassis provides a switched serial communication link between the service port and any module in the hub including the supervisory module By connecting a terminal to t...

Страница 36: ...flash card connector the backplane interface connector and the plastic front panel Figure 1 5 Model 5782 VNR Module The assembly includes inserter extractor levers and captive retaining screws at the top and bottom of the module front panel Each Model 5782 VNR occupies one slot in the Model 5000BH chassis The router module connects directly to the Model 5000BH ATM backplane 6500 Metal frame Insert...

Страница 37: ...flash memory card The flash memory card provides storage for the router nonvolatile file system NVFS including software to boot the router independently of the other modules in the Model 5000BH chassis The flash memory card also stores the image file and configuration files and scripts One flash memory card provides the image and configuration files for any number of routers installed in the Model...

Страница 38: ...The VBM module attaches to the router baseboard Segmentation and Reassembly of Packet Data Segmentation and reassembly operate at the ATM adaptation layer AAL by mapping user information into cell payloads 48 bytes of a 53 byte cell When the Model 5782 VNR is installed in the Model 5000BH chassis the VNR handles segmentation and reassembly of incoming packets to ATM cells and outgoing ATM cells to...

Страница 39: ...following information and procedures Topic Page Arranging Modules in a Model 5000BH Chassis 2 2 Preparing for Installation 2 4 Installing the VNR Module 2 6 Installing Airflow Modules 2 9 Verifying the Installation 2 10 Removing and Replacing the VNR 2 11 Removing the Flash Memory Card 2 13 Protecting the Files on the Flash Memory Card 2 14 Upgrading Memory 2 15 ...

Страница 40: ...module in one of these slot ranges you must also install an MCP switch module such as the Model 5724M or Model 5728M ATMSpeed MCP module in the same range of slots You can install up to four Model 5782 VNR modules two per Centillion ATM bus in a Model 5000BH chassis You can also use any slot designated for switch modules for a standard Ethernet token ring or FDDI module with the appropriate backpl...

Страница 41: ...1 Model 5000BH Chassis Backplanes Slot 1 Slot 2 Slot 13 Slot 14 FDDI or 100 Mb Ethernet backplane 1 14 Power Common management bus Ethernet 1 14 PPX bus 2 13 Model 5000BH backplane ATM bus 2 7 8 13 Token ring 1 14 or 1 7 8 14 108EC Standard Model 5000 backplane ...

Страница 42: ...stall the Model 5782 module in the chassis for the first time you should install a flash memory card The router needs a flash memory card with a valid boot image and configuration file in order to boot After the router boots and is running you can remove the card or install another one You need only one flash memory card for any number of routers in a chassis with a PPX backplane Additional router...

Страница 43: ...the card receptacle 3 Insert the card into the receptacle and gently push the card until it fits snugly into place Figure 2 2 Inserting the Flash Memory Card into the Model 5782 VNR Note If you install a new flash memory card that you did not obtain from Bay Networks you must format the card before writing to it You can format the card using Site Manager or the Technician Interface format command ...

Страница 44: ...igure 2 3 Figure 2 3 Removing a Filler Panel 2 Verify that the Model 5782 VNR contains a flash memory card See Installing the Flash Memory Card 3 Extend the router module inserter extractor levers to the vertical position parallel to the front of the module Figure 2 4 Note Install airflow modules in empty chassis slots to maintain the cooling airflow within the chassis For installation instruction...

Страница 45: ... bottom of the chassis slot 5 Slide the router module into the chassis until you feel it engage the backplane Keep the inserter extractor levers in the vertical position and in contact with the front of the chassis Do not push the VNR all the way into the chassis 6 Seat the router backplane connectors by rotating the inserter extractor levers toward the center of the module front panel Figure 2 5 ...

Страница 46: ...el 5782 ATM Virtual Network Router 2 8 119557 A Rev 00 Figure 2 5 Seating the Module 7 Using the flat tip screwdriver tighten the captive retaining screw at either end of the VNR module front panel 4690 2 Model 5000 ...

Страница 47: ...stall an airflow module 1 Remove the filler panel from the chassis slot where you intend to install the module see Figure 2 3 2 Orient the module with the large direction arrow pointing up Figure 2 6 and align the top and bottom edges of the module with the metal guides in the chassis slot Figure 2 6 Airflow Module Orientation 3 Slide the airflow module into the chassis 4 Replace the filler panel ...

Страница 48: ...ioning properly the LEDs light as follows during the diagnostic and boot sequence The annunciator lights amber After successfully completing diagnostics it lights green The Diag LED remains amber while the module runs its diagnostics The Diag LED turns off after successfully completing diagnostics The BP LED remains green to indicate connection to the ATM backplane After the module successfully co...

Страница 49: ...dix B Model 5782 VNR LEDs For information about troubleshooting other modules in the Model 5000BH chassis see Configuring System 5000 Cell switched Networks If the conditions described do not exist but you suspect that the Model 5782 VNR is failing run the diagnostics available through the Technician Interface For information about how to initialize and use the diagnostics see Using Technician Int...

Страница 50: ...Installing the Replacement VNR To install the replacement VNR follow the procedure described in Installing the VNR Module Note If you remove a module from the chassis permanently or for more than a few minutes install an airflow module and a filler panel in the empty slot Model 5000 Inserter extractor lever Captive retaining screw 3249 10 ...

Страница 51: ...he card receptacle Figure 2 9 and pull the card out of the receptacle Figure 2 9 Removing the Flash Memory Card To replace the flash card with another card insert the card into the receptacle and push the card until it fits snugly into place Note If you install a new flash memory card that you did not obtain from Bay Networks you must format the card before writing to it You can format the card us...

Страница 52: ...igure 2 9 2 Adjust the read write protect switch which is located on the edge of the card opposite the INSERT arrow Figure 2 10 Figure 2 10 Flash Memory Card Read Write Protect Switch 3 Insert the memory card as described in Installing the Flash Memory Card Note You typically do not operate a router with a write protected memory card Bay Networks recommends making a copy of your configuration on a...

Страница 53: ...he form of dual inline memory modules DIMMs that reside on the printed circuit board You can upgrade DRAM to a maximum of 64 MB to accommodate future network requirements Added DRAM is packaged in a 64 MB upgrade kit To order a memory upgrade kit contact your local Bay Networks sales office or account representative or call Bay Networks Sales at 1 800 8 BAYNET ...

Страница 54: ......

Страница 55: ...2 VNR in a Model 5000BH chassis you configure the VNR to access the network This chapter describes the following procedures required to start the configuration process Topic Page Configuring the MCP 3 2 Accessing the Model 5782 VNR over ATM 3 2 Accessing the Model 5782 VNR over the PPX 3 14 ...

Страница 56: ... backplane you must first provide an initial configuration to the ATM backplane interface Using the Quick Start installation script install bat you can configure the interface to use a PVC to act as a LAN emulation client or to run Classical IP over ATM To initialize the Model 5782 VNR using the Quick Start script you need to perform the following tasks Connect a terminal to the Model 5000BH chass...

Страница 57: ... the serial port on your PC or terminal Most terminals or PCs use a DB 9 or DB 25 plug connector See Table 3 1 To connect a terminal or PC to the chassis service port 1 Turn on the terminal and configure it using the parameters in Table 3 2 Table 3 1 Service Port Pin Assignments Terminal To Service Port DB 9 Pins DB 25 Pins Function DB 9 Pins Function 2 3 Receive data 2 Transmit data 3 2 Transmit ...

Страница 58: ...d in the chassis by slot number and lists the available commands Figure 3 1 Slot Selection Menu for the Model 5000BH Chassis Model 5000 Slot Selection Menu 01 12 98 11 47 30AM Slot Status Module Description 1 On Line 5308P Ethernet Host 2 On Line 5782 Virtual Net Router 3 On Line 5724M 4 Port MMF ATM MCP Host Module 4 On Line 5782 Virtual Net Router 5 On Line 5308P Ethernet Host 6 Removed 5782 Vir...

Страница 59: ...e t to start the Technician Interface The following information appears Control transferred to Technician Interface Enter X to return to CMB Interface 6 Press Enter A copyright statement and a login prompt appear 7 Enter the following case sensitive login password the first time you log into the Technician Interface Manager The Technician Interface welcome screen appears 8 Go to the next section P...

Страница 60: ...tion in Appendix C Network Information Worksheet Reviewing the Installation Files The Model 5782 VNR stores installation files on flash memory cards The nonvolatile file system NVFS running in the device reads and writes to the memory cards After establishing a Technician Interface session as described in Starting the Technician Interface display the Quick Start installation files and verify their...

Страница 61: ...he router volume Make sure you have enough space on the volume to hold any new files you write or copy VOL STATE TOTAL SIZE FREE SPACE CONTIG FREE SPACE 11 FORMATTED 4194304 172470 172470 File Name Size Date Day Time areboot ppc 301200 01 12 98 Mon 17 27 03 arediag ppc 368481 01 12 98 Mon 17 29 33 config 1688 01 12 98 Mon 15 29 33 debug al 12456 01 12 98 Mon 15 39 33 install bat 186303 01 12 98 Mo...

Страница 62: ...he Quick Start procedure you save your new configuration information to a file called startup cfg Do not edit the ti_5000 cfg file or overwrite it with another configuration file If the installation fails you must reboot the VNR with ti_5000 cfg before retrying the Quick Start procedure You also should boot with the ti_5000 cfg file if The router is currently running a configuration file other tha...

Страница 63: ...er The router boots and runs through its startup procedure 2 Establish a new Technician Interface session See Starting the Technician Interface for instructions Completing the Network Information Worksheet Before you run the Quick Start installation script you should fill out the Quick Start ATM worksheet see Appendix C Network Information Worksheet You will use your completed worksheet to respond...

Страница 64: ...isplays the startup banner and the introduction Figure 3 5 Note Use install bat once to configure the initial interface To configure other interfaces use Site Manager to create new configurations Table 3 4 Technician Interface Quick Start Commands Task Key Sequence Details Accept a default value Press Enter Your terminal displays default values in brackets for example ATMSR_XXXXXXX Repeat a step f...

Страница 65: ...ion This part of the Quick Start procedure configures the initial IP network interface on the router You perform this procedure so that the router can communicate with the network management station Each step of this procedure is further described in the Quick Start Guide As you perform the procedure refer to the Quick Start Guide for additional helpful information and examples When you are finish...

Страница 66: ...r workstation If the ping test is successful the initial IP interface is enabled and the script displays this message Quick Start Installation Completed Configuration Summary Net Module ATM_VNR_BH Module Number 3 Connector 1 Slot 10 Circuit Name ATMSR_1410301 6 IP address 192 168 13 72 IP subnetwork mask 255 255 255 0 Routing Protocol RIP1 Default Rt Listen No TFTP Default Volume 7 TI TELNET Yes H...

Страница 67: ...mask address of the Site Manager PC or workstation If the Site Manager workstation is on a different network verify that the router is operational Enter the show ip routes command at the Technician Interface prompt to examine the routing table and verify that there is a route or a default route to the network where the Site Manager workstation is located For more information about the show command...

Страница 68: ...ian Interface session choose File then choose Exit Accessing the Model 5782 VNR over the PPX To access the Model 5782 VNR over the PPX backplane you must already have another router installed and configured in the Model 5000BH chassis You can then do the following 1 Modify the existing configuration file for the Model 5000BH chassis using Site Manager 2 Use that configuration file to boot the Mode...

Страница 69: ...al specifications for the Model 5782 VNR module It contains the following sections Topic Page Physical Specifications A 2 Memory A 2 Backplane Interface Data Rates A 2 Electrical Specifications A 2 Electromagnetic Emissions A 3 Environmental Specifications A 3 Safety Agency Approvals A 3 ...

Страница 70: ...he following memory types DRAM Dual inline memory modules DIMMs 32 MB expandable to 64 MB PCMCIA flash memory card 8 MB minimum Virtual buffer memory VBM 1 MB resident 5 MB on VBM module Backplane Interface Data Rates The Model 5782 VNR supports the following backplane interface data rates ATM data rate 3 2 Gb s to each ATM bus PPX data rate 1 Gb s Electrical Specifications Your installation site ...

Страница 71: ...Class A VFG 243 Environmental Specifications The environmental requirements for the Model 5782 VNR are as follows Operating temperature 41 to 104 F 5 to 40 C Storage temperature 13 to 158 F 25 to 70 C Operating altitude Up to 10 000 ft 3 050 m maximum Operating humidity 85 maximum relative humidity noncondensing Storage humidity 95 maximum relative humidity Safety Agency Approvals UL CUL listed CS...

Страница 72: ......

Страница 73: ...a single LED called the annunciator and a matrix of LEDs that indicate specific operating conditions of the module Figure B 1 Figure B 1 LED Display for the Model 5782 VNR 5782 Virtual Network Router ATM Module Status PPX Transmit PPX Arbiter Run A B C D Boot Diag BP PPX Rx Tx 6387 1 Annunciator A B C D ...

Страница 74: ...Green The module is in the process of booting Off The module has completed the boot process or is unable to boot Diag Amber Module diagnostics are running or the diagnostics have failed If the Run LED is green the module is resetting Off The module has successfully completed diagnostics BP Green The master control processor MCP recognizes the Model 5782 VNR in the backplane Amber The MCP does not ...

Страница 75: ...record Creating an ATM circuit Adding the initial virtual circuit to the service record PVCs only Enabling the IP protocol on the ATM service record Sample Quick Start Network Setup Before running the install bat script you must first connect a terminal or PC to the Model 5000BH service port In addition you must also have a Site Manager workstation residing on the network to fully configure the Mo...

Страница 76: ... chassis Model 5782 VNR connects to an ATM network using an MCP module You configure a service record type using the script and then run IP over the connection IP address 192 168 125 34 Subnet mask 255 255 255 0 Connect a PC or ASCll console locally to the Model 5782 VNR to access the Technician Interface and run the installation script install bat Remote Bay Networks edge device for example a rou...

Страница 77: ...for LAN emulation or Classical IP connectivity If you choose to configure the interface for LAN emulation or Classical IP connectivity you must also configure a routing protocol for example IP to operate over that connection The Quick Start script continues with IP SNMP FTP TFTP Telnet and testing information worksheets beginning with the IP Configuration section See Quick Starting Routers for inf...

Страница 78: ... SNAP RFC 1483 2 NLPID RFC 1490 2 NLPID RFC 1490 For VPI enter a number from 0 to 255 The VPI virtual path identifier number of the initial PVC identifies the virtual path of the PVC The VPI is part of the cell header The header can contain a maximum of 8 VPI bits This bit range allows for path identifiers from 0 through 255 0 For VCI the valid range of a Model 5782 VNR installed in a 5000BH chass...

Страница 79: ... Mandatory and a 13 byte Net Prefix Optional to be combined into a 20 byte ATM address Enter User Part Mandatory 7 bytes Enter Net Prefix Optional 13 bytes No 12345677654321 3900000000000000000 0000000 Choose the Emulated LAN Name Press Return to accept the default ELAN name or type the name of a previously configured ELAN for this LAN Emulation client to join AAA Choose Emulated LAN Type 1 1 Unsp...

Страница 80: ...Net Prefix Optional to be combined into a 20 byte ATM address Enter User Part Mandatory 7 bytes Enter Net Prefix Optional 13 bytes No 12345677654321 3900000000000000000 0000000 Choose the ATM ARP Mode Client Mode Default Server Mode If you choose the default Client Mode you must enter the ARP Server ATM Address Would you like to accept Client Mode for ATM ARP y n y Yes Enter ARP Server ATM Address...

Страница 81: ...t script for the Model 5782 VNR The first example shows an ATM PVC setup The second example shows a LAN emulation setup and the third example shows a setup for Classical IP For instructions about running the script see Chapter 3 Starting the Model 5782 VNR Enter the information you completed in Appendix C Network Information Worksheet ...

Страница 82: ...refer to the Quick Start Guide for additional helpful information and examples When you are finished with this procedure the router will be able to communicate with the network management station over the IP network You are then ready to install the network management software as described in in the Quick Start Guide Each procedure step requires you to do one of the following things 1 Enter a numb...

Страница 83: ... 1 Communication type and connector number Ethernet 10bT1 IP address of initial IP network interface 192 32 10 189 Subnet mask of initial IP network interface 255 255 255 0 IP address of Site Manager workstation 192 32 10 200 Do you wish to continue y n y Step 1 Specify the slot number where the Net Module resides Slot Menu for Net Module Slot Module Net Module Processor Module 8 1 SFNM 5580 8 2 S...

Страница 84: ...ATM Logical IP Subnet Enter ATM Service Record Type 1 1 Configuring PVC ATM Service Record ATM PVC Encapsulation Type Menu 1 LLC SNAP RFC1483 2 NLPID RFC1294 1490 Enter Encapulation Type 1 1 For VPI please enter a number between 0 and 255 Enter VPI number 0 For VCI please note the following valid ranges if it is ARE installed in BLN BCN 32 65535 if it is 5780 ATM Router in 5000 AH 130 2047 if it i...

Страница 85: ...ince the router is not on the same network as the Site Manager workstation an IP Routing Protocol must be configured in order to manage the box remotely IP Routing Protocol Configuration Menu 1 RIP 2 OSPF 3 Static Route to Site Manager Enter Routing Protocol Number 1 RIP Configuration Default Route RIP will listen to a specific route to the network or subnet where Site Manager is located If you al...

Страница 86: ...ment is optional It allows you to limit control of this router to a single Site Manager workstation at a given IP address The default is to allow any Site Manager from any workstation to manage and to configure the router Note You can later configure this using Site Manager Do you wish to set SNMP community management y n n Step 4 Select TFTP default volume TFTP Default Volume Menu NVFS File Syste...

Страница 87: ... 13 72 IP subnetwork mask 255 255 255 0 Routing Protocol RIP1 Default Rt Listen No TFTP Default Volume 7 TI TELNET Yes HTTP Server No NOTE The Connector value in the above Configuration Summary is the Connector number of the 5782 Module backplane ATM port Note however that within the event log and the MIB browsing utilities such as Site Manager s Quick Get and the Technician Interface s debug scri...

Страница 88: ...tes IP ping 192 168 13 72 is alive size 16 bytes IP ping 192 168 13 72 is alive size 16 bytes IP ping 192 168 13 72 is alive size 16 bytes IP ping 192 168 13 72 is alive size 16 bytes This test attempts to ping the Site Manager workstation NOTE If routing has not yet converged an attempt to ping the Site Manager workstation may fail If this happens you may either enter a new IP address or quit and...

Страница 89: ...o the Quick Start Guide for additional helpful information and examples When you are finished with this procedure the router will be able to communicate with the network management station over the IP network You are then ready to install the network management software as described in in the Quick Start Guide Each procedure step requires you to do one of the following things 1 Enter a number that...

Страница 90: ...le resides 4 Communication type and connector number Ethernet 10bT1 IP address of initial IP network interface 192 32 10 189 Subnet mask of initial IP network interface 255 255 255 0 IP address of Site Manager workstation 192 32 10 200 Do you wish to continue y n y y Step 1 Specify the slot number where the Net Module resides Slot Menu for Net Module Slot Module Net Module Processor Module 8 1 SFN...

Страница 91: ... Signaling Version 1 2 ATM Signaling UNI3 1 Has Been Enabled ATM Address Configuration If you choose Auto Generation router software will use combination of MAC address and network prefix queried from server to generate a unique ATM address If you do not choose Auto Generation please enter a 7 byte User Part Mandatory and a 13 byte Net Prefix Optional to be combined to a 20 byte ATM address Do you...

Страница 92: ... the router connected to the same local area network as the Site Manager workstation y n n Since the router is not on the same network as the Site Manager workstation an IP Routing Protocol must be configured in order to manage the box remotely IP Routing Protocol Configuration Menu 1 RIP 2 OSPF 3 Static Route to Site Manager Enter Routing Protocol Number 1 RIP Configuration Default Route RIP will...

Страница 93: ...ng up SNMP community management is optional It allows you to limit control of this router to a single Site Manager workstation at a given IP address The default is to allow any Site Manager from any workstation to manage and to configure the router Note You can later configure this using Site Manager Do you wish to set SNMP community management y n n Step 4 Select TFTP default volume TFTP Default ...

Страница 94: ...fault volume is 7 Step 6 Enable TELNET Enable the Technician Interface via TELNET Do you want to enable TI TELNET y n n y TI TELNET enabled Step 7 Enable HTTP Enable the HTTP Web Server Do you want to enable the HTTP Web server y n n Configuration Summary Net Module ATM_VNR_BH Module Number 3 Connector 1 Slot 10 Circuit Name ATMSR_1410301 8 IP address 192 168 13 92 IP subnetwork mask 255 255 255 0...

Страница 95: ...as Connector 31 Press RETURN to continue Step 7 Specify a name for the configuration file Save configuration to a file The Quick Start configuration of the router is now complete and active Do you wish to save this configuration to a file y n y n Step 8 Test this initial IP interface configuration TEST IP Interface IP Interface 192 168 13 92 is up Testing local IP interface ping IP 192 168 13 92 r...

Страница 96: ...re refer to the Quick Start Guide for additional helpful information and examples When you are finished with this procedure the router will be able to communicate with the network management station over the IP network You are then ready to install the network management software as described in in the Quick Start Guide Each procedure step requires you to do one of the following things 1 Enter a n...

Страница 97: ... 1 Communication type and connector number Ethernet 10bT1 IP address of initial IP network interface 192 32 10 189 Subnet mask of initial IP network interface 255 255 255 0 IP address of Site Manager workstation 192 32 10 200 Do you wish to continue y n y Step 1 Specify the slot number where the Net Module resides Slot Menu for Net Module Slot Module Net Module Processor Module 8 1 SFNM 5580 8 2 S...

Страница 98: ...ng Logical IP Subnet ATM Service Record Enter Signaling Version 1 UNI3 0 2 UNI3 1 Signaling Version 1 2 ATM Signaling UNI3 1 Has Been Enabled ATM Address Configuration If you choose Auto Generation router software will use combination of MAC address and network prefix queried from server to generate a unique ATM address If you do not choose Auto Generation please enter a 7 byte User Part Mandatory...

Страница 99: ...Since the router is not on the same network as the Site Manager workstation an IP Routing Protocol must be configured in order to manage the box remotely IP Routing Protocol Configuration Menu 1 RIP 2 OSPF 3 Static Route to Site Manager Enter Routing Protocol Number 1 RIP Configuration Default Route RIP will listen to a specific route to the network or subnet where Site Manager is located If you a...

Страница 100: ...pt Client Mode for ATM ARP y n y Client Mode is chosen for ATM ARP ATM address of ARP server must be entered in two parts User Part 7 bytes and Network Prefix 13 bytes Set up ARP Server ATM Address Please enter ATM address in hex format omit leading 0x 0X Enter Network Prefix Mandatory 13 bytes 39000000000000000000000000 Enter User Part Mandatory 7 bytes 00929292929200 SNMP Community Management Me...

Страница 101: ...ume is 7 Step 5 Select FTP default volume FTP Menu Do you want to enable FTP y n n y NVFS File System VOL STATE TOTAL SIZE FREE SPACE CONTIG FREE SPACE 7 FORMATTED 2097152 1212913 834054 12 FORMATTED 16777216 8311573 7999315 Enter volume number 7 FTP default volume is 7 Step 6 Enable TELNET Enable the Technician Interface via TELNET Do you want to enable TI TELNET y n n y TI TELNET enabled Step 7 ...

Страница 102: ...pts connectors are numbered by a combination of their Connector number and Module number The interface you have selected will henceforth be referred to as Connector 31 Press RETURN to continue Step 7 Specify a name for the configuration file Save configuration to a file The Quick Start configuration of the router is now complete and active Do you wish to save this configuration to a file y n y n S...

Страница 103: ...ling 2 6 2 9 module placement in 2 2 CMB common management bus 1 13 command line interface 1 5 1 14 commands dinfo 3 6 dir 3 7 run install bat 3 10 show ip circuits 3 13 show ip routes 3 13 common management bus CMB 1 13 configuration files booting with ti_5000 cfg 3 8 displaying 3 6 startup cfg 3 12 configuring initial IP interface on Model 5782 VNR 3 10 MCP to recognize Model 5782 VNR 3 2 termin...

Страница 104: ... support 1 10 IP interface configuring initial 3 10 L LAN emulation LANE ATM described 1 8 worksheet information C 5 LEDs descriptions B 1 verifying installation 2 10 logical classical IP ATM worksheet information C 6 M MCP master control processor configuring to recognize Model 5782 VNR 3 2 described 1 12 memory flash card installing 2 4 removing 2 13 technical specifications A 2 upgrading 2 15 v...

Страница 105: ...el 2 6 flash memory card 2 13 module 2 11 reset button description 1 15 router backplane 1 12 router configuration example 1 3 router software image 3 8 routing and bridging protocols 1 7 RS 232 cable 3 3 run install bat command 3 10 running Quick Start installation script 3 10 S SAAL 1 8 safety agency approvals A 3 SAP service access point 1 9 SAR segmentation and reassembly 1 16 scripts configur...

Страница 106: ...terminal connecting to service port 3 3 thermal rating A 2 ti_5000 cfg file booting with 3 8 tools and equipment required for installation 2 4 troubleshooting LEDs 2 11 B 1 Quick Start installation 3 13 U upgrading memory 2 15 V VBM virtual buffer memory 1 16 verifying installation 2 10 virtual buffer memory VBM 1 16 virtual network router VNR 1 2 volume locating 3 6 W worksheet Quick Start C 1 wr...

Отзывы: