baxter SP600 Series Скачать руководство пользователя страница 1

FORM 36702 Rev. B (July 2009)

SP600 SERIES

WATER METER

Baxter • 19220 State Route 162 East • Orting, WA 98360 •

Phone: (360) 893-5554 • Toll free: 1-800-280-2495 • Fax: (360) 893-6128

Model Number: 

___________

Serial Number: 

___________

Date of Installation: 

___________

Operation/

Installation

Manual

Содержание SP600 Series

Страница 1: ...ES WATER METER Baxter 19220 State Route 162 East Orting WA 98360 Phone 360 893 5554 Toll free 1 800 280 2495 Fax 360 893 6128 Model Number ___________ Serial Number ___________ Date of Installation ___________ Operation Installation Manual ...

Страница 2: ...r Supply 6 Drain Connections 6 Plumbing Connections 7 Assembly 9 Setting Water Pressure 9 OPERATION 10 Environmental Conditions 10 Controls 10 Before First Use 12 Using the SP600 Water Meter 13 Using the Temperature Probe 14 Flush Time 15 Shutdown 15 CLEANING 15 MAINTENANCE 16 Service and Parts Information 16 Calibration Check 16 TROUBLESHOOTING 20 ...

Страница 3: ...rical service agrees with the specifications on the data plate located on the left panel of the water meter If the supply and equipment requirements do not agree do not proceed with the installation Contact the Bakery Systems service department immediately UNPACKING This water meter was inspected before leaving the factory The transportation company assumes full responsibility for safe delivery up...

Страница 4: ...Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 electric equipment In Europe 1 Local codes ELECTRICAL CONNECTIONS Electrical and grounding connections must comply with the applicable portions of the national electrical code and or other local electrical codes Appliances equipped with a flexible electric supply cord are provided with a three prong grounding plug This plug must be conn...

Страница 5: ...r Chiller Option If water chiller is pump driven connect the chiller to the water meter as described in the steps below Connection to the water chiller circuit should be done by a qualified electrician or service technician The auxiliary switch is located in the top mounted junction box Disconnect the electrical power to the machine and follow lockout tagout procedures 1 Verify that the water chil...

Страница 6: ...minimum WATER HARDNESS 4 to 6 grains per gallon 0 7 to 1 0 grains per liter is recommended DRAIN CONNECTIONS FIG 3 The water meter should be located near a sink for the bypass line to drain into while test flowing or when water is adjusting to a set temperature For water meters equipped with a water chiller and with a water reservoir a bypass return line should be connected back to the water chill...

Страница 7: ...tting or threading of pipes pipe joint compound from the lines or if soldered fittings are used bits of solder or cuttings from the tubing Debris if not removed may lodge in the valves and render them inoperative Manualvalvesorsolenoidvalvesdamagedbyforeignmatter andanyexpensesresultingfromthisdamage may not be covered under warranty Water Chiller Option 1 Connect the water meter cold water supply...

Страница 8: ... 8 WATER METER WITH PLUMBING CONNECTIONS NOTE The Hot and Cold Water Supply lines can vary in location Fig 5 ...

Страница 9: ...to the bottom panel of the meter SETTING WATER PRESSURE For the water meter to operate properly the water pressure should be set at 30 psi 207 kPa on each regulator while it is operating at 125 F 52 C See Operation on the following pages for a description of the control panel 1 Press CHANGE UNITS to select English or Metric units If the CHANGE UNITS key is locked see Locking and Unlocking the Chan...

Страница 10: ...robe The temperature window displays the temperature recorded by the hand held probe The probe measures the temperature of the room dough or flour The temperature range is 32 F to 125 F 0 C to 52 C Water Temperature SETTING window Displays the water temperature as the water meter is dispensing It also displays the selected water temperature when the meter is idle FULL COLD light Indicates the mixi...

Страница 11: ...ELIVERED window Displays the amount of water dispensed in pounds and ounces BY PASS light Indicates the meter is dispensing out of the bypass line DELIVERING light Indicates the meter is dispensing the entered water amount out of the dispenser hose INTERRUPTED light Indicates the meter has stopped before all of the water amount could be delivered COMPLETED READY light Indicates the meter has dispe...

Страница 12: ...ey Press to enter desired water temperature Enter the value on the numeric key pad SET AMOUNT key Press to enter the amount of water you would like to dispense Enter the value on the numeric key pad START RESUME key Press to dispense the entered water amount Press to resume dispensing cycle after an interruption STOP 0 key Press to stop dispensing water BEFORE FIRST USE The water meter should be c...

Страница 13: ...f the Water Meter is flowing water to either the bypass or delivery lines or is paused in this process The Water Meter automatically saves the unit change on the power down Setting Water Temperature Water Amount and Dispensing 1 Press SET TEMP 2 Enter desired temperature on the numeric key pad The water temperature value is displayed in the WATER TEMPERATURE window 3 Hook the dispensing hose over ...

Страница 14: ...ed into the end of the flexible cable attached to the bottom panel of the meter 2 Place the end of the probe where the temperature needs to be measured The HAND HELD PROBE TEMPERATURE window will display the temperature reading NOTE The probe can be used to measure the temperature of the room dough or flour in the range of 32 F 0 C to 125 F 52 C The probe must be in place for 30 seconds to get an ...

Страница 15: ... numeric key pad 7 Press START RESUME to save this setting SHUTDOWN Shutdown procedures should be followed when the water meter is not used for an extended period of time 1 Close the hot and cold water supply valves 2 Empty any remaining water from the dispensing hose 3 Place the dispensing hose on the hook located on the side of the water meter 4 Unplug the power cord from the electrical outlet C...

Страница 16: ...nt Three Samples Will Need To Be Collected NOTE Wait at least 30 seconds between taking consecutive samples 1 Set water delivery amount to 6 lbs 4 oz which equals 100 ozs 2 Hook the dispensing hose over the rim of a sample container 3 Press START RESUME to dispense a water sample Do not drain the remaining water from the dispensing hose between sample collections If the dispensing hose is dropped ...

Страница 17: ...ow 1 Press SET TEMP 2 Enter 32 using the numeric keypad 3 Press SET AMOUNT 4 Enter 95505 using the numeric keypad The WATER AMOUNT SETTING window displays 955 lbs 05 oz 5 Press START RESUME The WATER TEMPERATURE SETTING window displays the current calibration value 6 Enter a new calibration value between 60 and 240 1 number is 1 second using the numeric keypad 7 Press START RESUME to store the new...

Страница 18: ... delivered See the example in Fig 7 High End Water Calibration 120 F 49 C 1 Press SET TEMP 2 Enter 32 using the numeric keypad 3 Press SET AMOUNT 4 Enter 96607 using the numeric keypad The WATER AMOUNT SETTING window displays 966 lbs 07 oz 5 PressSTART RESUME TheWATERTEMPERATURESETTING window displays the current calibration value 6 Enter a new calibration value between 0 and 30 1 number is 0 5 F ...

Страница 19: ... 32 using the numeric keypad 3 Press SET AMOUNT 4 Enter 97708 using the numeric keypad The WATER AMOUNT SETTING window displays 977 lbs 08 oz 5 PressSTART RESUME TheWATERTEMPERATURESETTING window displays the current calibration value 6 Enter a new calibration value between 0 and 30 1 number is 0 5 F so 0 7 5 F 15 0 F and 30 7 5 F The default value is 15 which is 0 degrees of the temperature offse...

Страница 20: ...ter a water amount Incorrect water amount has been entered Enter pounds and ounces within the correct range Pounds 0 to 999 Ounces 0 to 15 Bypass flow is time out See Changing Time Out For Bypass Flow on page 16 The dispensed water amount does not match the amount delivered The dispensing hose was drained Always use the dispensing hook on the meter between dispensing tasks to prevent accidental dr...

Отзывы: