baxter PW1E Скачать руководство пользователя страница 5

– 5 –

ADVANCED CONTROLS - STANDARD PROOFER

PROOF MODE

ON/OFF -

 Press to start/stop the proof mode.

TEMP UP

 or 

DOWN ARROW -

 Press to set the 

temperature.

TEMP WINDOW -

  Displays  the  current 

temperature.

%HUMIDITY UP

 or

 DOWN ARROW -

 Press to 

set the humidity.

%HUMIDITY WINDOW -

  Displays  the  current 

humidity.

NOTE: 

When the actual humidity is less than 26%, 

the humidity window will show 25%. When the actual 

humidity is higher than 25%, the humidity window will 

show the actual humidity. To view the temperature or 

humidity set point, touch the up or down arrow once.

TIMER NUMBER

UP ARROW -

  Press  to  select  a  timer 

 

(1 through 4).

START/STOP -

 Press to start/stop the selected 

timer.

TIMERS UP

 or 

DOWN ARROW -

 Press to set 

the desired time on the selected timer.

TIMERS WINDOW -

  Displays  the  hours  and 

minutes remaining on the selected timer.

TEMP

%HUMIDITY

ON

ON

ON   

 

OFF   

 

TIMER

TIMERS

NUMBER

ON

START   

 

STOP   

 

Содержание PW1E

Страница 1: ...ting WA 98360 9236 Phone 360 893 5554 Fax 360 893 1337 www baxtermfg com Model Number ___________ Serial Number ___________ Date of Installation ___________ Operator Manual FORM 36756 Feb 2019 PROOFER RETARDER PROOFER MODELS PW1E PW1S PW2E PW2S PW3S RPW1S RPW2E RPW2S ...

Страница 2: ...dvanced Controls Retarder Proofer 7 Operating parameter setup 14 Customized Operation 16 Select Proofer Model VIA Bootloader 17 Update the Proofer Firmware VIA Bootloader 18 Control Board Power Up 19 LCD Contrast Adjustment 19 MAINTENANCE 20 Light Bulbs 20 Shut Down 20 Cleaning 20 Service and Parts Information 20 TROUBLESHOOTING 20 ...

Страница 3: ...ler temperature slows the yeast fermentation process and prevents the dough from rising The Automatic Retard Proof feature adds the flexibility of programming times to retard and automatically proof in one operation The Proofers and Retarder Proofers offer a unique modular design allowing for a wide variety of sizes in standard models They can be ordered as one two or three section roll in models ...

Страница 4: ... temperature between 36 F and 38 F 2 C to 3 C for best results Thawing frozen dough at retarder temperatures takes approximately 6 hours minimum Retarding slows the yeast fermentation process reduces gas formation and inhibits the dough from rising This also provides an excellent environment for storing dough products up to 48 hours by keeping the dough interior cool Dough should not be refrozen a...

Страница 5: ... 26 the humidity window will show 25 When the actual humidity is higher than 25 the humidity window will show the actual humidity To view the temperature or humidity set point touch the up or down arrow once TIMER NUMBER UP ARROW Press to select a timer 1 through 4 START STOP Press to start stop the selected timer TIMERS UP or DOWN ARROW Press to set the desired time on the selected timer TIMERS W...

Страница 6: ...ration 1 Press the UP arrow button next to the TIMER NUMBER window to select one of four timers The number will be displayed in the TIMER NUMBER window 2 Enterthedesiredtimebypressingthe UPorDOWN arrow next to the TIMERS window 3 PresstheSTART STOPbuttontoactivatethetimer The small ON dot located in the lower right corner of the TIMER NUMBER window blinks to indicate the timer is running 4 When th...

Страница 7: ...s to set the humidity level HUMIDITYWINDOW Displaysthecurrenthumidity Displays set humidity when being adjusted TIMER NUMBER ARROW Press to select a timer 1 to 4 TIMER START STOP BUTTON Presstostart stop the timer TIMERS UP or DOWN ARROW Press to set the desired time TIMERS WINDOW Displays the hours and minutes remaining on the timer ARROW BUTTONS Use with LCD operation LCD PANEL Displaysallsetupo...

Страница 8: ...8 42am Friday After entering desired time and pressing the timer START STOP button the LCD displays message PROOFTIMINGoooo toindicatetheproofoperation is now running with timers Fig 4 Tostoptheprooftimeroperation pressSTART STOP button To stop the proof operation press CHANGE MODE arrow button or ON OFF button NOTE Itisnormaltonoticethatprooferfansinairduct keep running for 20 minutes to cool dow...

Страница 9: ...p Mode See chart for default value During defrost cycle active the LCD flashes DEFR at the bottom left corner Enter the desired timer and press timer START STOP button The LCD displays message RETARDER TIMINGoooo to indicate the retard operation is running with timer Fig 5 and Fig 6 To stop the retard timer press timer START STOP button Tostoptheretardoperation press CHANGE MODE arrow button or ON...

Страница 10: ...r the next day Follow the steps below to program automatic Retard Proof operation After pressing Review Edit Settings the next screen on the LCD is shown here Fig 8 Review Edit Settings Start Retard Proof CHANGE MODE RETARDER PROOFER Today is Friday Change DAY NEXT 7 DAY PROGRAM In Figure 8 the LCD displays 7 DAY PROGRAM because the parameter P15 value is set to 1 NOTE This step is for service onl...

Страница 11: ... button ACTIVATE Program EXIT NEXT Sunday Program is INACTIVE skipped Operator also has the choice to skip the program on that day by pressing NEXT button or arrow button Fig 11 INACTIVATE Program EXIT NEXT Sunday Program is ACTIVE will proof Enter the desired time when to complete Proofing by pressing Hours and Minutes arrow buttons Keep in mind that hour or minute is changed by one arrow button ...

Страница 12: ... TEMP Sunday Program EXIT NEXT After entering the Retard temperature press NEXT button or arrow button to go to the Proof setup as shown in Fig 16 and Fig 17 EXIT NEXT See ABOVE for PROOFING SETTINGS Sunday Program Operator can enter desired temperature humidity and timer to end proof operation This is the end of Retard and Proof cycle for one day See ABOVE for PROOFING SETTING Sunday Program EXIT...

Страница 13: ...ual Retard or manual Proof by pressing CHANGE MODE arrow button Otherwise the auto Retard Proof operation will start after the arrow buttonispressedasshowninFig 19 Again the LCD displays a choice of the next day program by activating or deactivating the program button To skip the next day the next day program must be inactive Then press NEXT button If next day program is activated then proceed wit...

Страница 14: ...utton and the ON OFF button Fig 20 After entering parameter setup mode Fig 21 the LCD panel shows function of each parameter definition For more information on parametervalue seetheparameter value chart to understand each parameter value PARAMETER SETUP Software Version Fig 21 Press up or down button to enter new value Press up or down button to select parameter number LCD displays function or eac...

Страница 15: ...n Max 480 min P13 Recovery Time Min 30 min Max 480 min P14 1 AM PM 0 Military Time P15 1 7Day 0 Single Day P16 Defrost Every xx hours Max 10 hrs P17 Defrost FOR xx minutes Max 60 min NOTE P0 thru P9 are for Proofer and Retarder Proofer P10 thru P17 are for Retarder Proofer only Default Parameter Values 0001 P0 Software Version Number F P1 F Fahrenheit C Celsius 15 P2 Temp Offset for Calib 15 P3 Hu...

Страница 16: ...r DOWN arrow to the left of the TIMERS display 4 To exit the setup mode press the ON OFF and TIMER NUMBER arrow button once to get back to normal operation NOTE There may be setup numbers in the setup mode that do not pertain to your particular proofer Do not attempt to set these Skip them and go to the next appropriate number Setup Guide Setup Number Setup Item 1 Degrees Fahrenheit 2 Temperature ...

Страница 17: ...Temperature display Fig 23 Fig 23 4 The current proofer configuration value will be displayed in the HUMIDITY display 1 2 or 3 5 Pressing the HUMIDITY UP ARROW will cycle through the configurations 1 2 or 3 Config 1 Proofer PW Config 2 Retarder Proofer RPW Config 3 Dehumidifying Proofer DPC1S 6 The configuration is saved by pressing the ON OFF button 7 The TEMP and HUMIDITY display LEDs will flash...

Страница 18: ... update 9 UPdt will be displayed in the TEMP display for 1 second 10 Strt will be displayed in the TEMP display for 1 second 11 The image file will be validated On a successful update Succ will be displayed on the TEMP display for 2 seconds The control board will reboot Remove flash drive and turn on the proofer with the ON OFF button Verify the correct proofer operating mode and parameters On an ...

Страница 19: ...ARROW TEMPERATURE UP ARROW ON OFF button 3 Keep holding the three buttons until conF is shown in the Temperature display Fig 23 4 The current proofer configuration value will be displayed in the HUMIDITY display 1 2 or 3 5 While in the normal bootloader mode hold down the HUMIDITY DOWN button and then press the TEMP UP button You will see the LED display change and the LCD will display the instruc...

Страница 20: ...materials bleach harsh chemicals or chlorinated cleaners Do not use steel wool on stainless steel surfaces Never spray down the proofer with water steam or power wash 5 Becautiouswithneworimprovedcleaningformulas useonlyafterbeingwelltestedinaninconspicious place SERVICE AND PARTS INFORMATION Contact your authorized service office for any repairs or adjustments needed on this equipment TROUBLESHOO...

Отзывы: