– 25 –
COLOR CODE DESCRIPTION
Action
Green
E85
Close Loading Door Close door. If door is closed, contact a Baxter authorized servicer.
Yellow
E5
Heating Error
Manual reset high temperature limit tripped. Heat disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow
E6
Heating Error
Manual reset rollout switch tripped. Heat is disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow
E10
Heating Error
Oven is heating slow. If burner is not running, try opening and
closing the loading door.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Yellow
E35
Rack Rotation
Motor Error
No rotation detected. Open loading door and check for rack/pan
jam.
• If there is no rack/pan jam or problem continues, contact a Baxter
authorized servicer.
Yellow
E75
Hood Ventilation
Error
Hood switch input not detected. Heat disabled.
• Bake/cook cycle can continue but heat is disabled. Bake/cook
time may need to be extended.
• Contact a Baxter authorized servicer to resolve issue.
Red
E8
Heating Error
Temperature sensor failure. Heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red
E9
Heating Error
High temperature detected. Shut off gas and/or breakers.
• Contact a Baxter authorized servicer to resolve issue.
Red
E15
Convection Fan
Error
Convection fan overheated. Motor timed out and heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red
E25
Rack Lift Motor
Error
Up switch not detected. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red
E26
Rack Lift Motor
Error
Down switch not detected. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red
E27
Rack Limit Switch
Error
Detecting up and down limits at the same time. Motor timed out.
• Contact a Baxter authorized servicer to resolve issue.
Red
E76
Hood Ventilation
Error
Possible hood switch failure. Heat disabled.
• Contact a Baxter authorized servicer to resolve issue.
Red
E95
Electronics
Overheated
Board temperature exceeded limit.
• Contact a Baxter authorized servicer to resolve issue.
Содержание OV520G1