Technical specifications
For technical enquiries e-mail [email protected]
3
50mm Min*
600mm
390mm
200mm Min
(300mm Min if
using 80/125mm
flueing system)
5mm Min
5mm Min
500mm Min
For Servicing
Purposes
In Operation
5mm Min
At least 1.5°
285mm
Baxi Solo HE
A
Series Wall mounted
high efficiency boilers
12kW
15kW
18kW
24kW
30kW
CONTROLS
Concealed User Controls
Yes
Yes
Yes
Yes
Yes
User Adjustable CH Temperature
Yes
Yes
Yes
Yes
Yes
LED Status/Fault Diagnosis Display
Yes
Yes
Yes
Yes
Yes
GAS
Gas Supply Pipe Size
15
15
15
15
15
Natural Gas
Yes
Yes
Yes
Yes
Yes
LPG (Butane/Propane)
No
No
No
No
No
Nominal Inlet Supply Pressure
20
20
20
20
20
Maximum Gas Rate
1.34
1.64
1.94
2.31
2.95
Heat Input Central Heating
13.3
12.0
16.9
15.2
20.2
18.2
24.5
22.1
33.8
30.4
H
eat Output CH Non Condensing
11.8
15.2
17.8
22
30.2
Heat Output CH Condensing
12.8
16.5
19.3
23.8
32.6
SEDBUK 2005 Seasonal Efficiency NG / LPG
90.5
91.3
90.4
90.9
90.9
SEDBUK 2009 Seasonal Efficiency NG / LPG
88.7
89.4
88.7
88.8
88.8
NOx Class
5
5
5
5
5
NOx Levels
13.1
29.0
11.7
37.0
48.0
ELECTRICAL
Electrical Supply
230V/50Hz 230V/50Hz
230V/50Hz
230V/50Hz
230V/50Hz
Permanent Live Required
No
No
No
No
No
Electrical Cable Required
3 core x 0.75mm
2
Power Consumption
80
80
80
80
80
External Fuse Rating
3
3
3
3
3
Internal Fuse Rating
3.15
3.15
3.15
3.15
3.15
Ingress Protection Rating
(without electro-mechanical timer fitted)
IPX2
IPX2
IPX2
IPX2
IPX2
Integral ‘Boiler Only’ Frost Thermostat
No
No
No
No
No
Pump Overrun
No
No
No
No
No
MECHANICAL & HYDRAULIC
Compartment Ventilation Required
None
None
None
None
None
Flow & Return Pipe Size
22
22
22
22
22
Condensate Discharge Pipe Connection
21.5
21.5
21.5
21.5
21.5
Bypass Required
No
No
No
No
No
Vertical Pipe Route
Within Case
CH System Inhibitor Required
Yes
Yes
Yes
Yes
Yes
CONCENTRIC FLUE SYSTEM
Outside Diameter
110
110
110
110
110
Standard Horizontal Flue Kit Length
850
850
850
850
850
Max Equivalent Length Horizontal
4 plus Terminal
Max Equivalent Length Vertical
4 plus Terminal
Equivalent Length per 135° Bend
0.5
0.5
0.5
0.5
0.5
Equivalent Length per 93° Bend
1
1
1
1
1
TWIN PIPE FLUE SYSTEM
Diameters
80/80
80/80
80/80
80/80
80/80
Max Equivalent Length Horizontal
(parallel pipes)
75
75
75
75
75
Max Equivalent Length Vertical
(parallel pipes)
75
75
75
75
75
Equivalent Length per 135° Bend
1.3 Air & 2.6 Flue
Equivalent Length per 90° Bend
4.8 Air & 9.6 Flue
WEIGHTS
Max Installer Lift Weight
26
26
26
26
26
Gross Packaged Boiler Weight
36.2
36.2
36.2
36.2
36.2
mm
mbar
m
3
/hr
kW Max Gross
kW Max Net
kW Max
kW Max
%
%
mg/kWh
Volts/Hz
Watts
Amps
Amps
mm
mm
mm
mm
m
m
m
m
mm
m
m
m
m
kg
kg
Solo installer brochure 8pages.indd 4