background image

Technical specifications

For technical enquiries e-mail [email protected]

3

50mm Min*

600mm

390mm

200mm Min

(300mm Min if

using 80/125mm

flueing system)

5mm Min

5mm Min

500mm Min

For Servicing

Purposes

In Operation

5mm Min

At least 1.5°

285mm

Baxi Solo HE 

A

 Series Wall mounted

high efficiency boilers

12kW

15kW

18kW

24kW

30kW

CONTROLS

Concealed User Controls

Yes

Yes

Yes

Yes

Yes

User Adjustable CH Temperature

Yes

Yes

Yes

Yes

Yes

LED Status/Fault Diagnosis Display

Yes

Yes

Yes

Yes

Yes

GAS

Gas Supply Pipe Size

15

15

15

15

15

Natural Gas

Yes

Yes

Yes

Yes

Yes

LPG (Butane/Propane)

No

No

No

No

No

Nominal Inlet Supply Pressure

20

20

20

20

20

Maximum Gas Rate

1.34

1.64

1.94

2.31

2.95

Heat Input Central Heating

13.3
12.0

16.9
15.2

20.2
18.2

24.5
22.1

33.8
30.4

H

eat Output CH Non Condensing

11.8

15.2

17.8

22

30.2

Heat Output CH Condensing

12.8

16.5

19.3

23.8

32.6

SEDBUK 2005 Seasonal Efficiency NG / LPG

90.5

91.3

90.4

90.9

90.9

SEDBUK 2009 Seasonal Efficiency NG / LPG

88.7

89.4

88.7

88.8

88.8

NOx Class

5

5

5

5

5

NOx Levels

13.1

29.0

11.7

37.0

48.0

ELECTRICAL

Electrical Supply

230V/50Hz 230V/50Hz

230V/50Hz

230V/50Hz

230V/50Hz

Permanent Live Required

No

No

No

No

No

Electrical Cable Required

3 core x 0.75mm

2

Power Consumption

80

80

80

80

80

External Fuse Rating

3

3

3

3

3

Internal Fuse Rating

3.15

3.15

3.15

3.15

3.15

Ingress Protection Rating
(without electro-mechanical timer fitted)

IPX2

IPX2

IPX2

IPX2

IPX2

Integral ‘Boiler Only’ Frost Thermostat

No

No

No

No

No

Pump Overrun

No

No

No

No

No

MECHANICAL & HYDRAULIC

Compartment Ventilation Required

None

None

None

None

None

Flow & Return Pipe Size

22

22

22

22

22

Condensate Discharge Pipe Connection

21.5

21.5

21.5

21.5

21.5

Bypass Required

No

No

No

No

No

Vertical Pipe Route

Within Case

CH System Inhibitor Required

Yes

Yes

Yes

Yes

Yes

CONCENTRIC FLUE SYSTEM

Outside Diameter

110

110

110

110

110

Standard Horizontal Flue Kit Length

850

850

850

850

850

Max Equivalent Length Horizontal

4 plus Terminal

Max Equivalent Length Vertical

4 plus Terminal

Equivalent Length per 135° Bend

0.5

0.5

0.5

0.5

0.5

Equivalent Length per 93° Bend

1

1

1

1

1

TWIN PIPE FLUE SYSTEM

Diameters

80/80

80/80

80/80

80/80

80/80

Max Equivalent Length Horizontal
(parallel pipes)

75

75

75

75

75

Max Equivalent Length Vertical
(parallel pipes)

75

75

75

75

75

Equivalent Length per 135° Bend

1.3 Air & 2.6 Flue

Equivalent Length per 90° Bend

4.8 Air & 9.6 Flue

WEIGHTS

Max Installer Lift Weight

26

26

26

26

26

Gross Packaged Boiler Weight

36.2

36.2

36.2

36.2

36.2

mm

mbar

m

3

/hr

kW Max Gross

kW Max Net

kW Max
kW Max

%

%

mg/kWh

Volts/Hz

Watts
Amps
Amps

mm
mm

mm

mm

m
m
m
m

mm

m

m

m

m

kg

kg

Solo installer brochure 8pages.indd   4

17/08/2012   17:06

Содержание Solo 12 HE

Страница 1: ...SOLO HE A Compact heat only boiler www baxi co uk ...

Страница 2: ... of engineering experience and industry firsts We were producing heating boilers before the first motor car was built or the first electric light bulb illuminated We re very proud of our long heritage of quality and innovation and that we continue to manufacture here in the UK All Baxi GAboilers are Energy Saving Trust Recommended products to give your customer added peace of mind The company is f...

Страница 3: ...lace any existing heat only boiler Energy Saving Trust Recommended Two year parts and labour warranty giving customers complete peace of mind through our award winning customer service division heateam 2 www baxi co uk The simple contemporary lines and soft curves are bound to appeal to customers as will the beautifully simple controls that make it easy to use Its clean compact space saving design...

Страница 4: ... x 0 75mm2 Power Consumption 80 80 80 80 80 External Fuse Rating 3 3 3 3 3 Internal Fuse Rating 3 15 3 15 3 15 3 15 3 15 Ingress Protection Rating without electro mechanical timer fitted IPX2 IPX2 IPX2 IPX2 IPX2 Integral Boiler Only Frost Thermostat No No No No No Pump Overrun No No No No No MECHANICAL HYDRAULIC Compartment Ventilation Required None None None None None Flow Return Pipe Size 22 22 ...

Страница 5: ...BAX Not illustrated Flue Terminal Deflector 248167 NOTE The 3 degree fall back on concentric flues can be reduced to 1 5 degree providing the flue system is adequately clamped in accordance with the installation instructions Key Item Description Specification OD Multifit Dimensions Sales Code Vertical Roof Terminal 70 110mm 242802 Vertical Flue Adaptor Boiler 110mm 5106888 Flue Extension 1000mm 11...

Страница 6: ...giving them complete peace of mind Once this initial warranty has expired they have the option of extending it Aftersales service heateam our award winning customer service division is our team of 270 Gas Safe registered engineers working across the UK to ensure your customers are happy with their investment in their Baxi boiler In fact it s like having your very own aftersales team Any problems e...

Страница 7: ...ly in the current economic climate That s why we ve set up works our great new business support scheme Far more than a loyalty programme works rewards genuine two way communication between you and Baxi Rewards Earn Business Points to spend on a range of gifts and business support Free Gas Safe notification Save time and money on Gas Safe notifications with works easy online process Next day call o...

Страница 8: ... recorded Contact us Baxi Brooks House Coventry Road Warwick CV34 4LL www baxi co uk This Brochure is printed on paper sourced from well managed forests controlled sources This Brochure is printed using vegetable based inks Please recycle this Brochure when you have finished with it Baxi policy is one of continual improvement and development The right to change specification and appearance without...

Отзывы: