1.0 Introduction
7
© Baxi Heating UK Ltd 2012
Fig. 1
Data Badge
Air Box Door
Lower Door Panel
Position of Label
Fig. 2
1.1
Description
1. The Baxi Solo HE
A
range are gas fired room sealed fan
assisted condensing central heating boilers.
2. The maximum outputs of the Baxi Solo models are:-
12 HE
A
- 11.82 kW (Non Condensing)
12.81 kW (Condensing)
15 HE
A
- 15.24 kW (Non Condensing)
16.49 kW (Condensing)
18 HE
A
- 17.81 kW (Non Condensing)
19.27 kW (Condensing)
24 HE
A
- 22.0 kW (Non Condensing)
23.8 kW (Condensing)
30 HE
A
- 30.18 kW (Non Condensing)
32.61 kW (Condensing)
Note: 30 HE
A
is pre-set at 22.0/23.8 kW - see section 10.8
for adjustment details. All boilers automatically adjust output
according to system load.
3. The boiler is designed for use on Natural Gas (G20).
4. The boiler is suitable for fully pumped open vented
central heating and domestic hot water systems and sealed
systems.
5. A label giving details of the model, serial number and Gas
Council number is situated on the rear of the lower door
panel (Fig. 1).
6. The boiler data badge is positioned on the air box door
(Fig. 2).
7. The boiler is intended to be installed in residential /
commercial / light industrial E.M.C. environments on a
governed meter supply only.
8. The boiler must be installed with one of the purpose
designed flues such as the standard horizontal flue kit, part
no 236921.
1.2
Important Information
Man-made mineral fibre
• Some component parts of this appliance (insulation pads,
gaskets and rope seals) are manufactured from man-made
mineral fibre.
• Prolonged or excessive exposure to this material may
result in some irritation to the eyes, skin or respiratory tract.
• It is advisable to wear gloves when handling these items.
• Irritant dust will only be released from the items if they are
broken up or subjected to severe abrasion. In these
instances a suitable dust mask and goggles should be worn.
• Always thoroughly wash hands after installation, servicing
or changing components.
• When disposing of any items manufactured from man-
made mineral fibre care must be exercised.
• If any irritation of the eyes or severe irritation of the skin is
experienced seek medical attention.