English
34
1.8 Electrical current
There is a danger of electric shock when working with elec-
trical current. For this reason:
• Switch off the power before beginning work on the pump,
confirm that the system is voltage-free, and ensure that it
cannot be switched on again accidentally.
• Do not kink or pinch the power cable or allow it to come into
contact with sources of heat.
• Never open the control module and never remove operat-
ing elements.
• The pump is protected against drips in accordance with IP
protection class (see rating plate). Protect the pump from
water spray. Do not immerse in water or other fluids.
• The connection must be secured by means of a residual-
current device (RCD).
2 Technical data
2.1 Data
*
Reference value for the most efficient circulators: EEI ≤ 0.20
Quantum MAXI
Connection voltage
1~ 230 V
±10%, 50 Hz
Temperature class
TF 95
Protection class IP
See rating plate
Energy Efficiency Index EEI
*
See rating plate
Nominal connection diameter
(screwed connection)
DN 25 (Rp 1),
DN 30 (Rp 1¼)
Water temperatures at a max. ambient
temperature of +40 °C
-10 °C to +95 °C
Max. ambient temperature
-10 °C to +40 °C
Max. operating pressure
6 bar (600 kPa)
Minimum inlet pressure at +95 °C
0.3 bar (30 kPa)
Содержание Quantum MAXI
Страница 2: ...Fig 1 Fig 2a Fig 2b H max H H min Hs Q Hs 1 2 H max H H min Hs Q ...
Страница 3: ...Fig 2c Fig 3 max H min 2 1 3 Q Fig 4a Fig 4b PE N L ...
Страница 4: ...Fig 4c Fig 4d Fig 4e Fig 5 ...
Страница 6: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...CONTACTO ESPAÑA 918 872 896 www baxi es información baxi es PORTUGAL 217 981 200 www baxi pt infopt baxi pt ...