3. COMMISSIONING THE BOILER
To light the boiler correctly, proceed as follows:
•
Power the boiler.
•
Open the gas tap;
•
Press button (approx. 2 seconds) to set the boiler operating mode as described in section 3.2.
N.B.:
if the SUMMER
, mode is set, the boiler will only light during a DHW demand.
•
To adjust CHW and DHW temperatures, press the +/- buttons as described in section 4.
WARNING
During initial ignition, the burner may not ignite (causing the boiler to shut down) until any air in the gas pipes is vented.
In this case, repeat the ignition procedure until gas reaches the burner. Press the RESET button ( ) for at least 2 seconds.
Figure 1
KEY TO SYMBOLS ON DISPLAY:
Enable heating mode
Flame present - figure 2
(power level 0 - 25%)
Flame modulation level - figure 2
(3 power levels)
Enable DHW mode
Generic fault
No water
(Low system pressure)
Numerical signal
(Temperature, fault code, etc.)
RESET
ECO mode
BUTTON KEY:
DHW temperature settings (°C)
CHW temperature settings (°C)
RESET (boiler reset)
ECO - COMFORT
MODE button (see section 3.2)
0609_2301
If the optional remote control device is connected, adjust the boiler using this device. See the instructions accom-
panying this accessory item.