7.0 Setting the Timer

7.1

Setting the Timer

The Electro-Mechanical Timer allows the central heating

system to be set every 15 minutes.

Using the three position switch the timer will allow either

constant operation, timed operation or central heating off. 

Move the switch button by sliding to the desired position.

Three position switch

(Fig. 7)

Constant (Top position):

The heating will be on

constantly irrespective of the position of the tappets.The

heating will be controlled by the main thermostat on the

appliance and/or any external controls.

Timed (Central position):

The heating will operate

according to the position of the tappets and be controlled as

above.

0

Off (Bottom position):

No central heating.

Domestic hot water will operate on demand.

To set the time of day

Turn the timer outer bezel clockwise, to align the pointer with

the correct time to the nearest 15 minutes

ensuring that A.M./P.M. is considered. 

Do not at any time

attempt to turn the bezel anti-clockwise.

To set the timed heating program

Decide which times of the day the central heating is required.

The heating will operate when the white tappets are set to

the outer edge of the bezel.

To ensure the heating stays OFF set the required tappets

inwards towards the centre of the bezel.

Each tappet represents 15 minutes.

For example: If the heating is not required between 

10 A.M. and 11 A.M. the four tappets anticlockwise from the

10 A.M. will be set inwards (Fig. 8).

2

3

4

5

AM

7

8

9

10

0

9

10

11

12

1

2

3

4

5

PM

7

8

9

10

11

12

1

2

3

4

5

AM

7

8

9

10

11

12

0

4

Constant

Time Pointer

Timed

Off

Rotate to adjust time

Off Position

On Position

Time Pointer

Fig. 7

Fig. 8

Содержание EcoBlue Advance Combi 33

Страница 1: ...m Combi User Guide Gas Fired Wall Mounted Condensing Combination Boiler 24 28 33 40 en United Kingdom Please keep these instructions in a safe place If you move house please hand them over to the next...

Страница 2: ...work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Leg...

Страница 3: ...lluminate when the boiler is in the central heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicato...

Страница 4: ...on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1...

Страница 5: ...ostat if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need hel...

Страница 6: ...ts position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising sho...

Страница 7: ...labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Figs 4 5 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm Fo...

Страница 8: ...faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occ...

Страница 9: ...ciency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type te...

Страница 10: ...mestic hot water will operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is consid...

Страница 11: ...Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly It can be found at the back of the installati...

Страница 12: ...Gas Safe registered engineers to visit If your product is in warranty everything is free of charge subject to our warranty terms and conditions If it is out of warranty we can still help and offer a...

Страница 13: ...iciency class A A A A A A A A Rated heat output Prated or Psup kW Space heating Annual energy consumption kWh GJ Water heating Annual energy consumption kWh GJ Seasonal space heating energy efficiency...

Страница 14: ...o B e g a k c a p f o s s a l c y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S R O n i y c n...

Страница 15: ...al expression 115 11 Prated whereby Prated is related to the preferential space heater Weighting of boilers 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7...

Страница 16: ...m i l c e g a r e v a r e d n u e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h r e t a W y t i c i r t c e l e y r a i l i x u A n o i t u b i r t n o c r a l o S r e t a e h n o i t a n...

Страница 17: ...or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame a...

Страница 18: ...12 0 Notes 18 Baxi Heating UK Ltd 2015...

Страница 19: ...12 0 Notes 19 Baxi Heating UK Ltd 2015...

Страница 20: ...l terms and conditions visit www baxi co uk terms Failure to adhere to terms and conditions will void your manufacturer s warranty Baxi Brooks House Coventry Road Warwick CV34 4LL Please ensure the bo...

Отзывы: