7
USER Section
(en)
7710400 (01-06/18)
160
Fan fault
Call the Authorised Service Centre.
178
Intervention of safety thermostat for excess temperature in
low temperature system
Call the Authorised Service Centre.
270
Overheating exchanger
Call the Authorised Service Centre.
317 162
Call the Authorised Service Centre.
Call the Authorised Service Centre.
384 164
Parasite flame (internal error)
Press and hold down for at least 2 seconds.
385 165
Input voltage too low
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
431
Exchanger sensor faulty
Call the Authorised Service Centre.
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.
5. BOILER INFORMATION MENU
Press and hold down
for at least 1 second, to display the information indicated in the table. Press
to exit.
DESCRIPTION
DESCRIPTION
00
Secondary fault internal code
06
Heating return temperature (°C)
01
Heating supply temperature (°C)
07
Flue sensor temperature (°C)
02
Outdoor temperature (°C)
08
Primary exchanger temperature (°C)
03
Indirect tank DHW temperature (boiler CH only)
09 - 13
Manufacturer information
04
Domestic hot water temperature
(boiler with plate exchanger)
14
Identification Open Therm communication
05
- - -
15 - 18
Manufacturer information
6. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
7. FILLING THE SYSTEM
Regularly check that the pressure displayed on the pressure gauge "
B
" is 1 - 1.5 bar,
with the boiler cold. If the pressure is too low, turn tap "
A
" to fill the boiler (figure to
side).
Take special care when filling the heating system. In particular, open any
thermostat valves in the system, ensure the water enters slowly in order to
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. BAXI declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler
from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the
AUTHORISED TECHNICAL SERVICE CENTRE.
8. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
bis
Содержание DUO-TEC COMPACT
Страница 23: ...23 7710400 01 06 18 r u...
Страница 25: ...25 r u 7710400 01 06 18 1 7 1 2 SI US 1 1 C 20 C 11 2 1 1 2 3...
Страница 28: ...7710400 01 06 18 28 r u 0 C 17 60 C 9 SECTION C G3 4 30 9 1 SECTION C A D B E C G1 2 G3 4 F...
Страница 38: ...7710400 01 06 18 38 r u 16 0 5 5 30 24 10 24 3 17 SECTION E Q H 18 SECTION F...
Страница 40: ...7710400 01 06 18 40 r u 19 4 CO2 CO2 6 On 3 303 1 ESC...
Страница 68: ...7710400 01 06 18 68 S E C T I O N C...
Страница 69: ...69 S E C T I O N C 7710400 01 06 18 A B C D E F 65 65 65 65 31 5 70 38 5 105 162 5 153 5 22...
Страница 70: ...7710400 01 06 18 70 S E C T I O N D 25 mm...
Страница 72: ...7710400 01 06 18 72 S E C T I O N E...
Страница 73: ...73 S E C T I O N F 7710400 01 06 18...
Страница 74: ...7710400 01 06 18 74 S E C T I O N G 2 1 D A C G H E F B...
Страница 75: ...75 S E C T I O N G 7710400 01 06 18...