43
For technical enquiries e-mail [email protected]
Solo HE
A
Power Consumption
80W
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an earthed supply)
Electrical Protection
IPX2
Internal Fuse Rating (BS 4265)
Fuse 3.15 AT (PCB)
Water Content
litres
2.6
pints
4.6
Static Head
max
30 metres (100 ft)
min
1 metre (3.25 ft)
Gas Connection
G1/2” B.S.P.
Flow Temperature (adjustable)
55° C to 78° C (± 5° C)
Recommended System Temperature Drop
Condensing 20°C 36°F
Inlet Pressure at Gas Valve (Natural Gas)
Min
18.1 mbar
Max
22.5 mbar
Controls
boiler thermostat, safety thermostat,
flow switch, electronic flame sensing,
temperature protection thermostat &
condensate blockage sensor
Low Head
0.2m (8 in) min
System Detail
fully pumped open vented & sealed systems
External Fuse Rating
3A
MX8013 - Technical pocket guide DL v14_post proof.indd 43