background image

26

Technical Helpline: 0844 871 1525

Neta-tec Combi GA

Flue options

Plume Displacement Kits Ø 60/100mm 

  Part No. 720627001
  Part No. 720622901

Plume Displacement 

Terminal Kit inc.1m 

Extension

  Part No. 720643401
  Part No. 720643301

Plume Displacement 

Kit Extension & 

Brackets

  Part No. 5121370
  Part No. 720648601

Plume Displacement 

Kit Bend - Pair

 Part No. 720644601

Stainless Steel PDK 

Guard Ø 60/100 - Air 

Intake

  Part No. 5121369
  Part No. 720648701

Plume Displacement 

Kit Bend

White

Black

IMPORTANT: 

If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum 

of 150mm from any opening windows or doors. 

The inlet of the PDK MUST be at least 300mm above ground or 

balcony level or any projection or ledge. A guard must be fitted where 

the inlet is below 2 metres.

500mm Min.

For Plume Displacement Kit permissible flue lengths please see page 13. 

MX8013 - Technical pocket guide DL v14_post proof.indd   26

30/08/2012   14:29

Содержание Duo-tec Combi GA

Страница 1: ...xi co uk This Brochure is printed on paper sourced from well managed forests and controlled sources This Brochure is printed using vegetable based inks Please recycle this Brochure when you have finis...

Страница 2: ...you and your business On page 59 we give you details of our award winning after sales support service heateam which is available 363 days a year providing you with absolute peace of mind For more info...

Страница 3: ...37 Flue groups technical specifications control options Baxi Solo HE A 38 43 Flue groups control options Accessories and controls 44 50 LZC overview 51 Baxi Solarflo 52 57 Features and benefits Baxi...

Страница 4: ...the UK We strive for perfection and always listen to customer feedback resulting in boilers like the Baxi Duo tec Combi GA that set new standards in efficiency and reliability As for reliability you...

Страница 5: ...nd off Once the home reaches the desired temperature the boiler simply adapts its output to maintain that temperature more effectively Less gas is used to re ignite the boiler reducing both fuel bills...

Страница 6: ...installation and transportation Natural gas and LPG ready No conversion kit required Multifit GasSaver compatible Saves up to 37 of gas used to heat hot water and cold water consumption by up to 7 Use...

Страница 7: ...om Overview Baxi Duo tec Combi GA Baxi Neta tec Combi GA Baxi Megaflo System Compact GA Baxi Solo HE A n 1 7 1 5 1 7 1 3 and cold water consumption ater comfort ycling ay valve sticking ypass MX8013 T...

Страница 8: ...91 0 Baxi Neta tec Combi 33 GA NG LPG 91 1 93 2 89 0 90 9 Baxi Megaflo System Compact GA Baxi Megaflo System Compact 12 GA NG LPG 91 1 93 2 89 1 91 1 Baxi Megaflo System Compact 15 GA NG LPG 91 1 93 2...

Страница 9: ...ue 720861201 Baxi Neta tec Combi 28 GA NG LPG Std Flue 720861301 Baxi Neta tec Combi 33 GA NG LPG Std Flue 720861401 Baxi Neta tec Combi GAStandard Flue 720870201 Baxi Megaflo System Compact GA Baxi M...

Страница 10: ...g window etc 300 D2 Below gutters soil pipes or drain pipes 25 75 E2 Below eaves 25 200 F2 Below balconies or car port roof 25 200 G2 From a vertical drain pipe or soil pipe 25 150 H2 From an internal...

Страница 11: ...window frame 2 Only ONE 25mm clearance is allowed per installation If one of the dimensions D E F G or H is 25mm then the remainder MUST be as shown in brackets in accordance with B S 5440 1 Terminal...

Страница 12: ...w or Door 150mm MIN IMPORTANT If fitting a Plume Displacement Flue Kit the air inlet must be a minimum of 150mm from any opening windows or doors NOTE The distance from a fanned draught appliance term...

Страница 13: ...10 8 6 4 2 1 2 3 4 5 6 7 8 Models Baxi Duo tec Combi 24 GA Baxi Neta tec Combi 24 GA Baxi Megaflo System Compact GA12 15 18 24 60 Exhaust metres Concentric 60 100 Flue metres 16 14 12 10 8 6 4 2 1 2...

Страница 14: ...Max CH Output kW Sales Code Duo tec Combi 24 GA 24 9 8 3 4 to 20 720117801 Duo tec Combi 28 GA 28 11 5 3 8 to 24 720118001 Duo tec Combi 33 GA 33 13 5 4 7 to 28 720118201 Duo tec Combi 40 GA 40 16 4...

Страница 15: ...art No 720635501 Offset Adaptor Elbow Part No 720550801 93 Low Profile Boiler Elbow Part No 5118576 Vertical Flue Terminal Part No 246144 Flat Roof Flashing Part No 720598701 STD Horizontal Telescopic...

Страница 16: ...tions Horizontal and vertical fluing options In line bend reduction amount 135 0 5m 93 1 0m Multifit Flue Group G 80mm 125mm Flue systems horizontal and vertical options Part No 5118580 Horizontal Flu...

Страница 17: ...lue Terminal Horizontal Termination Part No 5111087 Flue Extension pair includes 2 brackets Part No 5111072 Flue Bend pair 90 Part No 5111086 Flue Bend pair 135 Part No 5111078 Vertical Flue Terminal...

Страница 18: ...44601 Stainless Steel PDK Guard 60 100 Air Intake Part No 5121369 Part No 720648701 Plume Displacement Kit Bend White Black IMPORTANT If fitting a Plume Displacement Flue Kit the air inlet must be a m...

Страница 19: ...19 For technical enquiries e mail technical helpline bdrthermea com Duo tec Combi GA Notes MX8013 Technical pocket guide DL v14_post proof indd 19 30 08 2012 14 29...

Страница 20: ...mensions Casing Height 763mm Overall Height Inc Flue 923mm Casing Width 450mm Casing Depth 355mm Appliance Type C13 C33 C43 C53 Appliance Category CAT I 2H 3P Electrical Supply 230V 50Hz Appliance mus...

Страница 21: ...OES NOT fall below 2 5l min This will ensure reliable operation of the DHW function Weights 24 28 model Packaged Boiler 41 5kg Installation Lift 36 kg 33 model Packaged Boiler 43 5 kg Installation Lif...

Страница 22: ...operation At least 1 5 290mm 5mm Min In operation 290mm 300mm with control panel flap Max DHW Output KW Flow Rate l m 35 Max CH Output kW Sales Code Neta tec Combi 24 GA 24 9 8 3 4 to 20 720023001 Net...

Страница 23: ...ertical Flue Terminal Part No 246144 Flat Roof Flashing Part No 5111068 Flue Terminal Deflector Black Part No 720643001 0 5m Flue Extension incl Fixing Screws Part No 720648501 135 Flue Bend incl Fixi...

Страница 24: ...ns Horizontal and vertical fluing options In line bend reduction amount 135 0 5m 93 1 0m Multifit Flue Group G 80mm 125mm Flue systems horizontal and vertical options Part No 5118580 Horizontal Flue K...

Страница 25: ...5111072 Flue Bend pair 90 Part No 5111084 Twin Pipe To Concentric Adapter 80 80 to 80 125 Part No 5111081 Flue Support Bracket pair 80mm Part No 5120172 Twin Flue Terminal Horizontal Termination Part...

Страница 26: ...nless Steel PDK Guard 60 100 Air Intake Part No 5121369 Part No 720648701 Plume Displacement Kit Bend White Black IMPORTANT If fitting a Plume Displacement Flue Kit the air inlet must be a minimum of...

Страница 27: ...27 For technical enquiries e mail technical helpline bdrthermea com Neta tec Combi GA Notes MX8013 Technical pocket guide DL v14_post proof indd 27 30 08 2012 14 29...

Страница 28: ...tails Casing Height 700mm Overall Height Inc Flue 860mm Casing Width 390mm Casing Depth 300mm Appliance Type C13 C33 C43 C53 Appliance Category CAT II 2H 3P Electrical Supply 230V 50Hz Appliance must...

Страница 29: ...flow rate DOES NOT fall below 2 5l min This will ensure reliable operation of the DHW function Weights 24 model Packaged Boiler 38 5kg Installation Lift 34 kg 28 model Packaged Boiler 38 5kg Installat...

Страница 30: ...290mm 150mm Min 390mm 175mm Min 300mm Min if using 80 125mm flueing system 5mm Min 5mm Min 700mm Heat Output kW Sales Code Megaflo System Compact 12 GA 2 to 12 720118501 Megaflo System Compact 15 GA 2...

Страница 31: ...oses In operation 345mm 345mm At least 1 5 150mm Min 763mm 450mm 175mm Min 300mm Min if using 80 125mm flueing system 5mm Min 5mm Min Heat Output kW Sales Code Megaflo System Compact 32 GA 4 6 to 32 7...

Страница 32: ...ing Screws Part No 720635501 Offset Adaptor Elbow Part No 5118576 Vertical Flue Terminal Part No 246144 Flat Roof Flashing Part No 720598701 STD Horizontal Telescopic Flue Kit positive fix Black Part...

Страница 33: ...ems horizontal and vertical options Part No 5118580 Horizontal Flue Kit 685mm Part No 5118588 Bend 91 5 Part No 5111078 Vertical Flue Terminal 80 125 Black use with 5111070 Part No 5118584 1m Flue Ext...

Страница 34: ...Bend pair 90 Part No 5111084 Twin Pipe To Concentric Adapter 80 80 to 80 125 Part No 5111081 Flue Support Bracket pair 80mm Part No 5120172 Twin Flue Terminal Horizontal Termination Part No 5111086 F...

Страница 35: ...end Pair Part No 720644601 Stainless Steel PDK Guard 60 100 Air Intake Part No 5121369 Part No 720648701 Plume Displacement Kit Bend IMPORTANT If fitting a Plume Displacement Flue Kit the air inlet mu...

Страница 36: ...opper tails Gas Inlet 22mm Heating Flow 22mm Heating Return 22mm Pressure Relief Discharge 15mm Appliance Type C13 C33 C43 C53 Appliance Category CAT I 2H 3P Electrical Supply 230V 50Hz Appliance must...

Страница 37: ...s can be reduced to 290mm by removing the boiler control access flap Outercase Dimensions Casing Height 763mm Overall Height Inc Flue 923mm Casing Width 450mm Casing Depth 355mm NOx Class 5 CO2 N G 9...

Страница 38: ...clearance will aid installation and maintenance 50mm Min 600mm 390mm 200mm Min 300mm Min if using 80 125mm 5mm Min 5mm Min 5mm Min 500mm Min For Servicing Purposes In Operation At least 1 5 285mm CH O...

Страница 39: ...ions Part No 243013BAX Horizontal Flue Terminal 0 85m Part No 236921 Horizontal Flue Terminal incl elbow Part No 241695 Flue Extension 1m Part No 241687 Flue Bend 93 Part No 5106888 Vertical Flue Boil...

Страница 40: ...0mm Part No 246136 Flue Extension pair 0 5m Part No 5121561 Flue Bend 2 pair 135 Part No 242757 Vertical Flue Boiler Adaptor Kit Part No 246135 Flue Extension pair 0 25m Part No 243015 Pitched Roof Fl...

Страница 41: ...ement Kit Bend Pair Part No 5121373 Plume Displacement Kit Bend IMPORTANT If fitting a Plume Displacement Flue Kit the air inlet must be a minimum of 150mm from any opening windows or doors The inlet...

Страница 42: ...aged Boiler 36 2 Packaged Flue Kit 3 6 Installation Lift 26 0 CO CO2 Ratio Up to a maximum of 0 004 CO2 Level 9 1 Appliance Type C13 C33 C53 Appliance Category CAT I 2H Injector Natural Gas 6 5mm Diam...

Страница 43: ...etre 3 25 ft Gas Connection G1 2 B S P Flow Temperature adjustable 55 C to 78 C 5 C Recommended System Temperature Drop Condensing 20 C 36 F Inlet Pressure at Gas Valve Natural Gas Min 18 1 mbar Max 2...

Страница 44: ...ime Temperature Control Baxi Wireless Programmable Room Thermostat 720030501 Additional items Baxi wired weather sensor 720103001 Multifit GasSaver GS1 720056901 GS1c 720855201 Multifit Heatsaver kit...

Страница 45: ...System Compact GA Baxi Solo HE A tat 720971601 l 24hr 720971401 timer kit 720645201 720818201 hr wire 720644901 mable t 720030501 ensor 720103001 GS1 720056901 GS1c 720855201 kit 720721001 scharge sa...

Страница 46: ...ge pump which removes the need for additional pipework Fitting Baxi has never been easier To be sited remotely from the boiler Simple to use tappet time clock in 15min adjustable time segments On Off...

Страница 47: ...ease of use and greater comfort 7 day programmable timer Easy to read backlit LCD display Compatible with Baxi Neta tec Combi GA and Baxi Duo tec Combi GA Plugs into boiler fascia for simple timer op...

Страница 48: ...Combi GA and Baxi Megaflo System Compact GA Standard GS1 for use with Baxi Duo tec Combi GA and Baxi Megaflo System 32 GA Saves up to 37 of the gas used to heat hot water annually Reduces cold water...

Страница 49: ...pared to a SEDBUK 2005 90 band A boiler Maintenance free no moving parts and no annual servicing required Simple to install designed for easy and fast fitting such as a standard airing cupboard Multif...

Страница 50: ...es with 17th Edition wiring regulations Baxi is pleased to present an addition to the Multifit accessory range the Multifit Condensate Trace Heating Kit The Multifit Condensate Trace Heating Kit is co...

Страница 51: ...ified Baxi Bioflo Baxi Solargen Baxi Geoflo The Baxi Bioflo is the ideal solution for homeowners who wish to take a proactive role in environmental protection The 94 efficient wood pellet biomass boil...

Страница 52: ...rs a sustainable energy source which is free and natural so it s becoming an attractive addition for customers and developers with an eye on the future Thanks to the superb design and the training we...

Страница 53: ...f kit to aid speedy installation Tool free hydraulic fittings to aid speedy installation and less time spent on the roof 3 2mm tempered low Iron glass cover to aid absorption of solar irradiation in c...

Страница 54: ...0670801 3 panel 720672101 Codes portrait Codes landscape 1 panel 720675301 1 panel 720676501 2 panel 720675501 2 panel 720676701 3 panel 720675701 3 panel 720676901 1 2 or 3 panels Solar controller Mo...

Страница 55: ...3 panels 2 0m2 or 1 or 2 panels 2 5m2 Solar controller Mounting rail and brackets Solar fluid Portrait or landscape options Slate flashing kit Pitched roof portrait application Suitable for On roof I...

Страница 56: ...essel Manifold 20 or 30 tubes Solar controller A frame Solar fluid 30m flexible stainless steel pipe kit Hydraulic Pump Station Manifold 20 or 30 tubes Solar Controller Mounting rail and brackets Sola...

Страница 57: ...throughout the day The solar controller supplied with the main hydraulic pump station see Installation Guide on www baxi co uk already has the facility built in to control an East West array A Baxi S...

Страница 58: ...y trainers with many years experience of Baxi products They re designed to help you understand the THINK combustion management system and boiler components and make installation service and maintenanc...

Страница 59: ...of installation will be resolved quickly and efficiently by one of our engineers If you re a member of our business support scheme works we will guarantee to be with your customer the very next day Ca...

Страница 60: ...ards Earn points to spend on a range of gifts and business support Free Gas Safe notification Save time and money on Gas Safe notifications with works easy online process Next day call out We ll suppo...

Страница 61: ...uctions 7206335 Installation Instructions 7206334 Homeowner sales brochure 396126 Baxi Neta tec Combi GA Sales Order Code User instructions 7206333 Installation Instructions 7206332 Homeowner sales br...

Страница 62: ...le 1609 m 1 609 km 1 square inch 645 2 mm2 6 452 cm2 1 cubic inch 16387 mm3 0 016 39 dm3 1 cubic yard 0 764555 m3 1 ton 1016 kg 1 016 tonne 0 1 inches water gauge 0 25 mbar 1 0 inch water gauge 2 5 mb...

Страница 63: ...mile 1094 yd 1 square millimetre 0 001550 in2 1 square metre 1 196 yd2 0 047 hectare 1 cubic millimetre 0 000061 in3 1 cubic decimetre 61 02 in3 0 035 31 ft3 1 cubic metre 35 31 ft3 1 308 yd3 220 0 g...

Страница 64: ...17 44 15 71 0 056 18 09 16 30 0 058 18 73 16 88 0 060 19 38 17 46 0 062 20 03 18 04 0 064 20 67 18 62 0 066 21 32 19 21 0 068 21 96 19 79 0 070 22 61 20 37 0 072 23 26 20 95 0 074 23 90 21 53 0 076 2...

Страница 65: ...140 45 22 40 74 0 142 45 87 41 32 0 144 46 51 41 90 0 146 47 16 42 48 0 148 47 80 43 07 0 150 48 45 43 65 m3 2 min kW gross kW net 0 152 49 10 42 23 0 154 49 74 44 81 0 156 50 39 45 39 0 158 51 03 45...

Страница 66: ...kW gross kW net 68 16 14 14 54 70 15 68 14 13 74 14 83 13 36 78 14 07 12 68 82 13 39 12 06 86 12 76 11 50 90 12 20 10 99 94 11 68 10 52 98 11 20 10 09 102 10 76 9 70 106 10 36 9 33 110 9 98 8 99 114 9...

Страница 67: ...dartford baxigroup com Web www bdrthermeaprofessionaltraining co uk Tel 0844 871 1540 Website www interpartspares co uk Tel 0845 605 4370 Email admin works2gether co uk Web www works2gether co uk Tel...

Страница 68: ...c co uk Building Engineering Service Association formerly HVAC Tel 020 7313 4900 Web www b es org Scottish Nothern Ireland Plumbing Employers Federation Tel 0131 556 0600 Email info snipef org Web www...

Страница 69: ...69 For technical enquiries e mail technical helpline bdrthermea com Useful contacts Notes Notes MX8013 Technical pocket guide DL v14_post proof indd 69 30 08 2012 14 30...

Страница 70: ...70 Technical Helpline 0844 8711525 Notes Notes MX8013 Technical pocket guide DL v14_post proof indd 70 30 08 2012 14 30...

Отзывы: