5.0 Care of the Boiler

8

© Baxi Heating UK Ltd 2015

5.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. 

DO NOT USE ABRASIVE

CLEANING AGENTS.

5.2

Protection & Precaution

1. The boiler incorporates an integral frost protection feature

that will operate in both modes. If the boiler temperature falls

below 5° C, then the boiler will operate until the water

temperature has been raised.

2. If a system frost thermostat has been fitted (your installer

will be able to advise you), then to operate correctly and

protect your system, the gas and electricity must be left on and

the appliance set in the central heating mode.

3. The boiler incorporates an integral pump protection feature

which continually monitors the time since the pump last

operated. To prevent seizure, the pump will operate for

approximately 1 minute if it has not run in the last 24 hours.

5.3

Fault Indication

1. If a fault occurs on the boiler an error code may be shown

on the facia display.

2. The codes are either two or three digit, preceded by the

letter 'E'. For example, code E133 will be displayed by 'E1'

alternating with '33'. E50 is shown as 'E' then '50'.

3. E20, E28, E50, E125 & E160 indicate faulty components.

You should make a note of the displayed error code and

contact your installer or service engineer.

4. If E110 or E130 is displayed overheat of the primary water

or flue system has occurred. Turn the selector switch to the

reset position and hold for at least 5 seconds. If the boiler

does not relight, or the code is displayed regularly contact your

installer or service engineer.

5. E119 is displayed when the primary water pressure is less

than 0.5 bar. After repressurising the system the boiler should

operate. Your installer will be able to advise you about the

method of repressurising. See page 6 for further details. 

6. E133 indicates that the gas supply has been interrupted,

ignition has failed or the flame has not been detected. Ensure

that the gas supply has not been turned off, and turn the

selector switch to the reset position and hold for at least 5

seconds. If the boiler does not relight, or the code is displayed

regularly contact your installer or service engineer.

 Central Heating NTC Fault

Flue NTC Fault

Hot Water NTC Fault 

Safety Thermostat Operated

Water Pressure Switch Not Operated

Circulation Fault (Primary Circuit)

Flue NTC Operated

Interruption Of Gas Supply or Flame Failure

Fan or Fan Wiring Fault

E20

E28

E50

E110

E119

E125

E130

E133

E160

Table of Error Codes

bar

0

1

2

3

4

Display

Then

Fig. 5

Содержание Duo-tec 28 LPG Combi ErP

Страница 1: ...mbi User Guide Gas Fired Wall Mounted Condensing Combination Boiler 24 28 33 40 28 LPG en United Kingdom Please keep these instructions in a safe place If you move house please hand them over to the n...

Страница 2: ...le to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Legislation 9 7 0 Wa...

Страница 3: ...ntral heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has...

Страница 4: ...on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1...

Страница 5: ...t if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help wi...

Страница 6: ...are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when re...

Страница 7: ...e the following minimum clearances for Safety and Maintenance Figs 3 4 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing This is the MINIMUM recommended di...

Страница 8: ...20 E28 E50 E125 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary...

Страница 9: ...iency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Bodies 00...

Страница 10: ...r installer and records that the boiler has been installed and commissioned correctly It can be found at the back of the installation and service manual and should be kept in a safe place for the life...

Страница 11: ...m of Gas Safe registered engineers to visit If your product is in warranty everything is free of charge subject to our warranty terms and conditions If it is out of warranty we can still help and offe...

Страница 12: ...A A A A A A A Rated heat output Prated or Psup kW Space heating Annual energy consumption kWh GJ Water heating Annual energy consumption kWh GJ Seasonal space heating energy efficiency Water heating e...

Страница 13: ...o B e g a k c a p f o s s a l c y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S R O n i y c n...

Страница 14: ...xpression 115 11 Prated whereby Prated is related to the preferential space heater Weighting of boilers 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7 1 0...

Страница 15: ...m i l c e g a r e v a r e d n u e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h r e t a W y t i c i r t c e l e y r a i l i x u A n o i t u b i r t n o c r a l o S r e t a e h n o i t a n...

Страница 16: ...9 0 Notes 16 Baxi Heating UK Ltd 2015...

Страница 17: ...9 0 Notes 17 Baxi Heating UK Ltd 2015...

Страница 18: ...9 0 Notes 18 Baxi Heating UK Ltd 2015...

Страница 19: ...any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter War...

Страница 20: ...l terms and conditions visit www baxi co uk terms Failure to adhere to terms and conditions will void your manufacturer s warranty Baxi Brooks House Coventry Road Warwick CV34 4LL Please ensure the bo...

Отзывы: