![Baxi BURNMOOR Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/baxi/burnmoor/burnmoor_operating-and-installation-manual_2712082009.webp)
Fig 4d
Fig 4e
Step 3.
To turn the main burner off while keeping
the pilot alight, rotate the operating
knob back to the
PILOT
position. (Fig 4e)
Fig 4f
Step 4
. To extinguish the pilot, turn the control knob
to the
OFF
position. (Fig 4f)
Incorporated into the pilot assembly is a flame
failure device designed to shut off the gas supply in
the event of the pilot flame being extinguished
while the fire is unattended.
Should the pilot flame blow out accidentally or
intentionally whilst the fire is running,
no attempt
should be made to re-light the gas for at least
three minutes.
To restart the fire turn the control knob to the off
position and repeat the lighting & controlling the
fire instructions.
The flame failure device is a safety feature required
by law and must not be put out of action by the
installer. If this device or any of its parts are to be
replaced, only original manufacturer's parts are to
be used.
Repeated operation of the flame failure device
indicates that there may be a problem with the flue.
In this situation no more attempts at operating the
appliance should take place and your gas
installation engineer should be contacted.
Baxi Gas Stoves
9
OPERATING INSTRUCTIONS