background image

RESETTING THE BOILER:
(Electronic Controls Boiler)

(45/3E, 57/3E, 45/4E & 57/4E)
If the boiler lockout light is illuminated
it is necessary to reset the appliance.
To do this turn the boiler thermostat
control knob fully anti-clockwise to
the OFF position and wait 10
seconds. Turn the control knob to the
required setting. The boiler will
commence sparking providing the
water temperature is sufficiently cool.

(51/5)
If the indicator light is illuminated
red/or flashing red, it is necessary to
reset the appliance. To do this turn
the boiler thermostat control knob
fully anticlockwise to the OFF position
and wait until the light shows orange.
Turn the control knob clockwise to
the required setting. The boiler will
commence the ignition sequence.

TO LIGHT THE FIRE:

Push in

and turn the fire control knob

slowly anti-clockwise to the positive
stop at position "   1". Just before
position "   1" is reached, a click will
be heard and the burner should light,
hold in the control knob for approx 15
seconds, release and turn to desired
position. If the burner fails to light,
turn the control knob to the OFF
position (   ) and repeat until the
burner lights. Continue to hold in the
control knob for a further 15 seconds.
Release slowly and the burner should
stay alight.

CAUTION -

If the burner does not light

or stay alight, or if the flame goes out for
any reason, turn the control knob to the
OFF position (   ) and wait for 3 minutes
before attempting to light the burner.

NOTE:

An electrical supply is not

needed to ignite the fire.

CONTROL KNOB POSITIONS: The
control knob has five positions giving
a choice of 4 settings, i.e. 

Position

- OFF

Position

1 - IGNITION/PILOT

Position

1 - LOW

Position

2 - MED

Position

3 - MED/HIGH

Position     4   -  HIGH

To adjust the fire to the required
setting, push in the control knob and
turn in the appropriate direction. 

There is no ‘Pilot Only’ position-the
pilot and burner low rate light
simultaneously at position      1.

When the control knob is turned from

1 to      the pilot is extinguished.

TO TURN THE FIRE OFF:
Push in the control knob and

turn clockwise to the OFF position(  ). 

8

9

TO SHUT DOWN THE BOILER

Turn the fire control knob to the OFF
position (  ),  and allow the fire to
cool.

Remove the controls cover panel at
the bottom of the fire by grasping it
firmly by its side edges and pulling
forwards.

To switch the boiler off for short
periods. (Manual Controls Boiler)

Turn the boiler thermostat knob to the
OFF position (   ). The pilot will
remain alight.

To switch the boiler off for long
periods. (Manual Controls Boiler)

Turn the grey push button clockwise
and release. Turn the boiler
thermostat knob to the OFF position 
(    ).

To switch the boiler off. (Electronic
Controls Boiler)

Turn the thermostat

knob to the OFF position (    ).

If you are shutting down both the fire
and boiler, isolate the electrical
supply that serves the system
controls i.e. Timer/Programmer.

Replace the controls cover panel.

NOTE:

If the boiler is left off for long

periods during cold weather, it is
recommended that the whole system is
drained to avoid frost damage. Advice on
draining the system can be obtained from
your Service Engineer.

10

page 5

1

2

3

4

Baxi Bermuda

PW5 Deluxe

4

3

2

1

B

A

X

I B

E

R

M

UD

A C5

Fire Control Knob

Controls
Cover Panel

Controls
Cover Panel

Controls
Cover Panel

PW5 Deluxe

C5W

C5

Position
Indicator
Button

Position
Indicator
Button

Fire Control Knob

(C5 shown)

Содержание Bermuda PW5 Deluxe

Страница 1: ... keep these Instructions safe Should you move house please hand them over to the next occupier Baxi Bermuda PW5 Deluxe C5 C5W Fireside Gas Central Heating Unit User s Operating Instructions PW5 Deluxe C5W C5 ...

Страница 2: ...ing boilers Baxi Bermuda 45 4 M G C No 44 077 71 Baxi Bermuda 45 4 E G C No 44 077 73 Baxi Bermuda 57 4 M G C No 44 077 72 Baxi Bermuda 57 4 E G C No 44 077 74 Baxi Bermuda 51 5 G C No 44 075 06 Baxi is a BS EN ISO 9001 Accredited Company Renewal Baxi Bermuda PW5 Deluxe Renewal G C No 37 075 10A Baxi Bermuda C5 Renewal G C No 37 075 07A Baxi Bermuda C5W Oak Renewal G C No 37 075 08A Baxi Bermuda C...

Страница 3: ...afety Installation Use Regulations The appropriate Building Regulations either The Building Regulations The Building Regulations Scotland Building Regulations Northern Ireland The Water Fittings Regulations or Water Byelaws in Scotland The Current I E E Wiring Regulations Where no specific instructions are given reference should be made to the relevant British Standard Code of Practice In IE the i...

Страница 4: ... by an external programmer or clock control see separate instructions with the clock controller used The fire is controlled by the knob which is located on the right hand side of the outer case PW5 Deluxe model on top of the outer case C5 C5W models Important Notice The Bermuda C5 Propane C5W Mahogany Propane are for use on PROPANE GAS ONLY and cannot be used on any other gas Propane appliances ca...

Страница 5: ...ing a choice of 4 settings i e Position OFF Position 1 IGNITION PILOT Position 1 LOW Position 2 MED Position 3 MED HIGH Position 4 HIGH To adjust the fire to the required setting push in the control knob and turn in the appropriate direction There is no Pilot Only position the pilot and burner low rate light simultaneously at position 1 When the control knob is turned from 1 to the pilot is exting...

Страница 6: ... C5W are Top 100mm 4 in Sides 70mm 23 4 in 76mm 229mm SPARE PARTS Any repairs to the appliance during the guarantee period will usually be the responsibility of the installer after which spare parts may be obtained through an approved Baxi stockists The spare parts available and their relevant part numbers and G C numbers can be found at the back of the installation and servicing instructions book...

Страница 7: ...d light Continue to hold in the control knob for a further 15 seconds Release slowly and the burner and pilot should stay alight CAUTION If the burner does not light or stay alight or if the flame goes out for any reason turn the control knob to the OFF position and wait for 3 minutes before attempting to light the burner CLEANING THE FIRE Ensure that the fire is cold The painted panels and metalw...

Страница 8: ... other manufacturers The guarantee operates from the date installation is completed for the customer who is the original user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain int...

Отзывы: