22
8.0
Changing Components - Page 22
8.1 Changing Components
1. To change any components on the back boiler it is
necessary to remove the fire front.
2. After changing any components carry out gas soundness
checks.
8.2 Removal of Firefront
1. Isolate the electrical supply to the appliance.
2. Turn the thermostat knob to the off position (Fig. 52).
3. Turn the gas service tap to the off position (Fig. 50).
4. Refer to the separate firefront instructions for the removal
of the firefront.
The following components can be changed with the
controls in situ:- Lint Arrestor, Suppression Capacitor,
Thermostat and Piezo Igniter Unit.
8.3 Lint Arrestor
1. Lift and remove the injector insulation pad (Fig. 51)
2. Remove the controls cover panel from its retaining clips
(Fig. 54).
3. Remove the lint arrestor by pulling forward (Fig. 53).
4. Reassemble in reverse order.
To change the Suppression Capacitor, Thermostat and
Piezo Igniter Unit proceed as follows:-
1. Remove the controls cover panel from its retaining clips
(Fig. 54).
2. Remove the control knob (Fig. 55).
3. Undo the screw retaining the valve cover and remove the
cover (Fig. 55).
8.4 Suppression Capacitor
(Fig. 56)
1. Note the positions of the electrical connections on the
valve and remove them.
2. Remove the capacitor connections from the valve.
3. Reassemble in reverse order.
Содержание Bermuda Inset 2 Boiler 50/4