SAFETY
Do
have the fire installed by a competent person. In the United Kingdom,
installation must be in accordance with the latest edition of the Gas Safety
(installation & use) Regulations. In the Republic of Ireland, installation must be in
accordance with all national and local regulations in force.
Do
have the chimney swept prior to installation if it was previously used for solid fuel.
Do
have the fire installed in accordance with the installation instructions.
Do
provide a minimum clearance of 860mm from the base of the hotbox to any
shelf made of wood or other combustible material where the shelf is not more than
150mm deep. For a shelf deeper than 150mm, add 12.5mm to the clearance for every
25mm of additional shelf depth (See graph1).
Do
provide a suitable guard that complies with BS 8423 for the protection of young
children, the elderly and the infirm. Such a guard is also recommended for the
protection of pet animals. (Although this fire conforms to all the applicable
Page 4
OWNER GUIDE
IF YOU SMELL GAS
DON’T SMOKE
EXTINGUISH ALL NAKED FLAMES
DON’T TURN ELECTRICAL SWITCHES ON OR OFF
TURN OFF THE GAS SUPPLY AT THE METER
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE - SEE YOUR
LOCAL TELEPHONE DIRECTORY
Graph 1. Combustible shelf clearances