Temperatures
C.H. Flow Temp (
adjustable
)
35°C to 85°C
max
(±5°C)
LPG Gases Propane - G31
Burner Injector
15 x 0.77mm diameter
Burner Pressure
Max Rate
Min Rate
Propane
mbar
34.4 ±0.5
5.1 ±0.5
in wg
13.8 ±0.2
2.0 ±0.2
Inlet Pressures
mbar
37
in wg
14.8
SEDBUK Declaration For System Boiler 60/100 IE
The seasonal efficiency (SEDBUK) is 78.2 %
This value is used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings. The test data from which it has been calculated have been certified
by 0051.
Page 8