9. The timer must supply a signal to the zone valve when there is no hot water demand in
order that port 'B' may be closed off.
10. It is not necessary to connect any control(s) to the boiler domestic hot water relay PCB.
As a result of this the domestic hot water thermostat will not operate and the cylinder
thermostat must be relied upon to limit the temperature of DHW.
11. The selector switch must be in the central heating and domestic hot water position at all
times for the boiler to operate.
Page 22
Scheme 2
Scheme 2
b -
blue
w -
white
o -
orange
br -
brown
gr -
grey
g/y - green/yellow
12.
Scheme 2
incorporates two 2 port zone valves and is based on an 'S' plan system. The
boiler will provide hot water to the central heating system, domestic hot water store or both.
13. The boiler is controlled by a live feed from either zone valve depending upon demand.
Содержание 35/80 IE