background image

Isolated DTE interfaces 
The InduBox GSM M4 has 2 galvanically isolated serial interfaces :

3- wire RS-232 (RxD, TxD, GND’)

  

3- wire RS-485 (A, B, GND’)

 

Those interfaces are galvanically separated and can be used to connect a serial device.
Both interface connections are done through one RJ-45 connector.

The V' - pin can be used for external reset (V') or for powering (100 mA Imax) an 
external device (+5V'), selectable via a JP6.

8x Status LED’s 
The InduBox GSM M4 has 8 status LED’s.

GSM module
The InduBox GSM M4 is using a Sierra Wireless CF

3

 footprint GSM module as WAN 

device. Thanks to the Sierra Wireless CF

3

 HL footprint for the WAN module, the InduBox

GSM M4 offers the flexibility to easily migrate communication technologies, thus making
it future proof. Depending on the application, the modem can be provided with standard 
3GPP cellular 2G GPRS, 3G UMTS, 4G LTE, LPWA (low power wide area), LTE Cat-M1
or NB-IoT. LPWA with 3GPP 2G GPRS fallback is also possible. Most modules are 
available for global or NAM, EMEA and APAC only regions.

The following options are possible (Q3 2018) :

3GPP

HL6528 – quad band GSM/GPRS & GSM Data
HL6528RD – quad band GSM/GPRS
HL8518 – dual band HSPA, GSM/GPRS/EDGE
HL8548 – quad band HSPA, GSM/GPRS/EDGE
HL7690 – FDE band LTE Cat-1 (*)
HL7692 – FDE band LTE Cat-1 with dual band GSM/GPRS/EDGE fallback (*)

LPWA

HL7800 – LTE Cat-M1, NB-IoT
HL7802 – LTE Cat-M1, NB-IoT with dual band GSM/GPRS fallback

(*) only with 1-SISO antenna connection

Содержание InduBox GSM M4

Страница 1: ...Installation Configuration manual InduBox GSM M4 V1 1 ...

Страница 2: ...ED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 29 01 18 V1 0 Preliminary Filip Lavaerts Creation V1 0 InduBox GSM M4 hardware manual 28 05 18 V1 1 Preliminary Filip Lavaerts Adding edit Wouter s info about configuration ...

Страница 3: ... Specifications 4 SIM Card 5 Ports and Connectors Mains Power Connection Isolated DTE Interfaces Isolated RS 232 connection Isolated RS 485 connection Pin 1 Ethernet interface Antenna interface Non isolated DTE interface 6 LED Indicators 7 InduBox GSM M4 HTML GUI Configuration A EC declaration of conformity B Basic Dimensions ...

Страница 4: ...Serial flow as used in this manual DCE DTE TxD RxD DTR DCD RTS CTS RI DSR GND Modem InduBox GSM M4 Communication device PC POS PLC Application IN OUT Data Terminal Equipment Data Communication Equipment ...

Страница 5: ...IP stack implementation and is able to connect non IP devices to an IP network over an Ethernet or GSM link The main specifications of the InduBox GSM M4 are InduBox wall mountable housing Configuration setup and monitoring via GUI HTML pages 8 x status LEDs 10 100 Mb Ethernet interface full RS 232 DCE serial interface galvanic isolated 2 wire RS 485 serial interface galvanic isolated 3 wire RS 23...

Страница 6: ...e specifications for details on voltage range Configuration Interface The InduBox GSM M4 modem has one complete TxD RxD DCD DTR RTS CTS RI and GND RS 232 interface This RS 232 interface is not isolated and can be used to configure and or debug tracing This interface has a RJ 45 connector Ethernet Interface The InduBox GSM M4 modem has one standard 10 100 Mbit s ethernet LAN interface This interfac...

Страница 7: ...or the WAN module the InduBox GSM M4 offers the flexibility to easily migrate communication technologies thus making it future proof Depending on the application the modem can be provided with standard 3GPP cellular 2G GPRS 3G UMTS 4G LTE LPWA low power wide area LTE Cat M1 or NB IoT LPWA with 3GPP 2G GPRS fallback is also possible Most modules are available for global or NAM EMEA and APAC only re...

Страница 8: ...ver 145 x 108 x 71 mm Connectors Mains plug and connector terminal block screw connector pitch 5 08 mm maximum wiring section 2 5 mm2 Female RJ 45 connectors RS 232 RS 485 RJ 45 Ethernet connector AMP 50 Ohm FME antenna connector 3 2 Environmental conditions Temperature in use 25 C 55 C Humidity in use 10 75 non condensing 3 3 Power Supply Specifications Input voltage range 90 253 Vac Input freque...

Страница 9: ...corner onto the PCB 4 Slide the upper part to the LEFT position 5 Rotate the SIM card holder upper part to the upright position 6 Insert the SIM card into the upper part of the card holder 7 Rotate back and close the upper part of the SIM cardholder 8 Finally slide the upper part to the right LOCK position 9 Close the InduBox GSM M4 enclosure 10 Connect mains power and DTE interface Power Supply G...

Страница 10: ...e power and or DTE plugs 5 1 Mains Power Connection PIN 1 N 2 L1 Always disconnect the mains power before connecting or disconnecting the power plug Make sure the voltage supplied to the modem is within range of the InduBox GSM M4 input voltage see specifications for details on voltage range There is no fuse or circuit breaker built in to the InduBox GSM M4 this must be added externally When the I...

Страница 11: ...wo isolated serial interfaces are possible on the same RJ 45 connector RS 232 3 wire V RS 485 3 wire V 5 2 1 Isolated RS 232 interface To be used when a RS 232 device must be connected to the InduBox GSM M4 Jumper settings JP7 JP8 on position 2 Connection PIN RS 232 Direction Level 1 V 5 25 Vdc in OR 5V out JP6 2 3 4 RXD DCE DTE V 28 5 TXD DTE DCE V 28 6 GND V 28 7 8 Ethernet ANT Mains N L1 Serial...

Страница 12: ...InduBox GSM M4 Jumper settings JP7 JP8 on position 4 Connection PIN RS 485 Level 1 V 5 25 Vdc in OR 5V out JP6 2 B V 11 3 4 A V 11 5 A V 11 6 GND 7 B V 11 8 UART 5V 5V TxD RxD 5V RXD TXD GND TTL V 10 Level Shift Ethernet ANT Mains N L1 Serial Interface RJ 45 8 contacts 1 8 Serial Term JP3 JP6 JP7JP8 2 4 Meter ...

Страница 13: ...en JP6 is not placed pin1 is not connected 5Vdc outgoing To have 5Vdc maximum 100mA onto pin 1 Input reset function Pin 1 is connected to a DI digital input via an optocoupler An input voltage of 5 to 25Vdc is needed to activate the DI Depending on the firmware this can for example reset the InduBox GSM M4 A B receiver transmitter DE 120 E JP3 UART 5V B A GND RxD TxD 5V 560 E 560 E Serial Term JP3...

Страница 14: ...2 168 1 44 255 255 255 0 HTML is available on standard port 80 5 4 Antenna interface The GSM antenna must be connected on the GSM modem via a cable depending on the application and the GSM RF field strength at the site The antenna interface connector is FME male Never use the InduBox GSM M4 modem without a proper antenna attached ...

Страница 15: ... 9 connector cable is available PIN V 24 Description Direction Level 1 DCD Data Carrier Detect DCE DTE V 28 2 RXD Receive Data DCE DTE V 28 3 TXD Transmit Data DTE DCE V 28 4 DTR Data Terminal Ready DTE DCE V 28 5 GND Ground 6 RI Ring Indicator DCE DTE V 28 7 RTS Request to Send DTE DCE V 28 8 CTS Clear to Send DCE DTE V 28 Power Supply GSM module Mains Serial Antenna Ethernet SIM L1 L2 GSM TXD RX...

Страница 16: ...FF No connection Slow flash WAN IP received ON TCP socket open GSM yellow GSM Network service DCE ON not registered on the network Slow flash 2 s OFF registered on the network Quick flash 600 ms OFF communication in progress TXD red Transmit Data DTE DCE TXD signal of the GSM module RXD red Receive Data DCE DTE RXD signal of the GSM module DTR red Data Terminal Ready DTE DCE DTR signal of the GSM ...

Страница 17: ...ne through a GUI via HTML The default ip address of the modem is 192 168 1 44 Username admin Password password Click on login to enter the configuration pages of the modem To make changes always save the change at the bottom of the page and reboot the modem before the change is executed ...

Страница 18: ...nterface which is the connection over the mobile network SIM Access pin code of the installed SIM card Network band indicator frequency band of the mobile connection Operator selection Network operator to which the modem is connected RSSI Received Signal Strength indicating the received power level A higher number indicates a better connection IP Address received used WAN IP address Netmask Uptime...

Страница 19: ...f the local Ethernet interface IP IP Address Set the IP address of the local Ethernet interface Subnet Mask Default gateway enter 0 0 0 0 when not in use DNS1 enter 0 0 0 0 when not in use DNS2 enter 0 0 0 0 when not in use DHCP Client Turn on to get an IP address from a DHCP server off for static ip Dynamic IP not visible on trace browser ...

Страница 20: ...Bits Parity Stop Bits Flow control Isolated interface Set the serial parameters of the isolated RS 232 RS 485 interface Should be the same as for the device connected Type this isolated interface can be hardware configured as an RS 232 3 wire or RS 485 2 wire interface See above JP7 JP8 Baudrate Data Bits Parity Stop Bits Driver Enable Delay Delay between sending the last character and disabling t...

Страница 21: ...accepts both CHAP and PAP connections At this moment only PAP CHAP can be used APN Access Point Network name depends on the service provider see SIM card documentation APNUN APN username some carriers use a user name and password for authentication should be provided by the carrier APNPW APN Password see APNUN MRU Maximum Receive Unit size max size of one packet received standard is 1500 which is ...

Страница 22: ...ata call TCP IP Modem will completely reset after this timeout with no TCP connection Basic router Device will completely reset after this timeout with no data sent received Periodical Ping Address In basic router or TCP IP mode the connection will be tested by a periodical ping GSM module will reset after 3 failed pings Can only be used if the WAN network allows pings 0 0 0 0 if not in use Period...

Страница 23: ...e The DinBox GSM M4 can act as a server expecting a TCP connection from a client or as a client connecting to a server Client Fill in this configuration if Client is selected client will connect to a remote TCP server Host IP address IP address of the remote TCP server Host Port Number Port number of the remote TCP server Connection Trigger Defines when the TCP client will connect to the remote TC...

Страница 24: ...tmask 255 255 255 255 to only allow one specific IP address NAT Configure port forwarding for the NAT in the modem Ethernet interface is the private network mobile network is the public network Don t forget to Enable the configured Port Incoming local traffic Remote HTTP access configure the Port on which the HTTP server is available for accessing the configuration GUI Radio button makes the port ...

Страница 25: ...nts with different amounts of prints info warning error Change Admin Password Change the password used to access the configuration web page default is admin password Factory Reset Will do a factory reset on all the parameters Software upgrade Updates the modem firmware Select Browse pick the correct file and upload Reboot Reboots the modem Should be done after any saved change in the modem configu...

Страница 26: ...m digital radio telephones immunity test CISPR24 10 V m 890 2400 MHz 1 freq step 1s dwell 50 duty 200 Hz repetition time TST25 3 30 V m 890 2400 MHz 1 freq step 1s dwell 50 duty 200 Hz repetition time EN61000 4 4 Electromagnetic compatibility part 4 section 4 Electrical fast transient burst immunity test CISPR24 0 5 KV and 1 KV 5 50 ns 5 Khz rep freq on AC mains TST25 3 2 KV and 4 KV 5 50 ns 5 Khz...

Страница 27: ... rep rate 40Hz applied on mains in common mode 1 MHz 1KV rep Rate 400 Hz applied on mains in differential mode 100 MHz 1KV rep Rate 40 Hz applied on mains in differential mode EN55022 Limits and methods of measurement of radiodisturbance characteristics of ITE equipment EN55022 class B limits AV QP Radiated emission 30 1000 MHz Conducted emission CISPR16 0 15 30 MHz EN55024 performance criteria fo...