A.
EC-Declaration of conformity
standard CE +
TST25-3 (additional extended immunity tests)
EN61000-3-2
Electromagnetic compatibility, part 3, section 2
Limits for harmonic current emissions.
EN61000-3-3
Electromagnetic compatibility, part 3, section 3
Limitations of voltage fluctuation and flicker.
EN61000-4-2
Electromagnetic compatibility, part 4, section 2
Electrostatic discharge immunity test.
CISPR24 : 4 KV contact / 8 KV air
TST25-3 :
8 KV contact (20 +/- contacts) / 15 KV air (20 +/-
discharges)
EN61000-4-3
Electromagnetic compatibility, part 4, section 3
Radiated fields immunity test.
CISPR24 : 10 V/m 80 MHz - 2000 Mhz, mod. AM 80% 1KHz
TST25-3 :
30 V/m 80 MHz - 2000 Mhz, mod. AM 80% 1KHz
ENV50204
Electromagnetic compatibility, Basic immunity standard, Radiated
Electromagnetic field from digital radio telephones immunity test.
CISPR24 : 10 V/m 890-2400 MHz, 1% freq step, 1s dwell, 50%
duty, 200 Hz repetition time
TST25-3 : 30 V/m 890-2400 MHz, 1% freq step, 1s dwell, 50%
duty, 200 Hz repetition time
EN61000-4-4
Electromagnetic compatibility, part 4, section 4
Electrical fast transient/burst immunity test.
CISPR24 : 0.5 KV and 1 KV 5/50 ns, 5 Khz rep. freq on AC mains
TST25-3 :
2 KV and 4 KV, 5/50 ns, 5 Khz rep freq on AC mains
EN61000-4-5
Electromagnetic compatibility, part 4, section 5
Surge immunity test.
CISPR24 : 10 pulses 1 KV 1,2/50 µs (5+ 5-) on AC mains
TST25-3 : 6 KV pulses
EN61000-4-6
Electromagnetic compatibility, part 4, section 6
Conducted immunity test.
CISPR24 :
3 V 0.15 MHz - 80 MHz, mod. 80% at 1 Khz on mains
TST25-3 :
10 V 0.15 MHz - 80 MHz, mod. 80% at 1 Khz on
mains
Magnetic fields
applied to all accessible surfaces
1000 At (ampere turns) – 1A on 1000 turns
EN61000-4-8
Electromagnetic compatibility, part 4, section 8
Power frequency magnetic field immunity test.
Содержание InduBox GSM M4