![Baumuller DSC Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/baumuller/dsc-series/dsc-series_commissioning-and-maintenance-instructions_2711390023.webp)
TAM 00682
23
DSC 045-100
07 / 2012
Three-phase synchronous motor
English
8.5
Fan connection
Figure 6: pole assignment of the fan
8.6
Control port: Resolver
Pin Signal Option for
allocation KTY on
encoder socket
View of the contact side of the built-in box
1
2
3
4
5
6
7
8
9
10
11
12
cos –
-
-
-
sin –
sin +
-
cos +
-
Ref +
-
Ref –
cos –
-
-
-
sin –
sin +
K –
cos +
K +
Ref +
-
Ref –
Figure 7: pole assignment resolver
contactside mounting box