3.4
137.36
Alarm mask
The parameter is only valid for EnDat
encoders.
The supported error messages of the connected encoder type are shown here.
137.37
Alarm buffer
The parameter is only valid for EnDat
encoders.
The error messages of the connected encoder type are displayed in this parameter. The
encoder sends an error message if the malfunction can result in wrong position values.
The cause of error will be displayed in this parameter.
Not generally all error messages were supported (see
Alarm mask).
The controller responds to a set error bit with a corresponding error (error numbers 406
to 412).
Bit
Supported error messages
0
1: Illumination failure
1
1: Signal amplitude
2
1: Position value
3
1: Overvoltage
4
1: Undervoltage
5
1: Overcurrent
6
1: Battery defect
Residual
Reserved
Bit
Monitoring according to
0
1: Illumination failure
1
1: Signal amplitude faulty
2
1: Position value faulty
3
1: Overvoltage occurred
4
1: Undervoltage supply
5
1: Overcurrent occurred
6
1: Battery change needed
Residual
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......