T
8
Erro
r
detetion
and
trouble
sho
oting
8.3.1
Monito
ring
funtions
-
explanations
Overcurrent HW
This monitoring function checks, if the motor current exceeds the output peak
current amplitude by more than 30%.
DC link
This monitoring function checks the voltage in the DC link. In case the voltage
drops below an adjusted limit value, the error„DC link undervoltage“ is displayed
by the controller. In case the voltage exceeds an adjusted value, the error „DC link
overvoltage“ is signaled from the controller and there is an immediate pulse inhibit.
Temperature of
controller PCB
This monitoring function checks the temperature of the controller PCB. There is a
distinction between warning and error thresholds. When exceeding the warning
threshold (but falling below the error threshold) a warning is displayed only. When
exceeding the error threshold besides the error message there is also an immediate
pulse inhibit released.
Temperature heat
sink
This monitoring function checks the temperature of the heat sink. If the error
threshold is exceeded, an error message is displayed and pulse inhibit is activated
immediately.
Temperature
motor
This monitoring function checks the temperature of the motor.
• If the I
2
t-threshold is exceeded, the warning „I
2
t-threshold“ is displayed by
the controller.
• If the I
2
t-value is exceeded by 100%, the error „I
2
t-overload“ is displayed by
the controller.
• If the temperature threshold 1 is exceeded the warning „temperature
threshold 1 exceeded“ is displayed by the controller.
• If the temperature threshold 2 is exceeded the warning „temperature
threshold 2 exceeded“ is displayed by the controller.
• The smallest value the PTC-sensor (KTY84) can provide is -30°C. In case this
temperature is exceeded or a short-circuit occurs at the sensor, the error
„Short-circuit temperature sensor“ is displayed.
• The highest value the PTC-sensor (KTY84) can provide is +260°C. If this
temperature is exceeded or the sensor is not connected, the error
„Temperature sensor not connected“ is signaled by the controller.
Position controller
This monitoring function checks the statical/dynamical position deviation limit. In
case the statical/dynamical position deviation error is greater than the adjusted
position deviation error limit, there is an error message „position deviation error
statical“ or „position deviation error dynamical“. After monitoring time (position
deviation time), additionally an error message is displayed and there is an
immediate pulse inhibit.
122
Instrution
Manual
b
maXX®
BM3400
from
206
Do
ument
No.:
5.07013.03
Baumueller
Kamenz
GmbH
Содержание b maXX BM3400 Series
Страница 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...T 0 10 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 144: ...T 10 Repair 144 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 165: ...De laration of Conformity C 5 T Instru tion Manual b maXX BM3400 165 Do ument No 5 07013 03 from 206 ...
Страница 191: ...E Appendix E List of gures Instru tion Manual b maXX BM3400 191 Do ument No 5 07013 03 from 206 ...
Страница 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Страница 196: ...T F Appendix F Index 196 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 202: ...T F Index 202 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 204: ......
Страница 205: ... ...