4. MAINTENANCE/CARE and CLEANING

 

 

Maintenance procedures

 

Please note:

 

Voltage carrying components - Risk of fatal injury! 
The kiln must be disconnected from the power source! 
Authorised personnel may not begin the maintenance procedures 
until a safety inspection has been carried out. 

 
 
 
 

 

Care and cleaning

 

 

Ensure that no foreign matter is allowed inside the firing chamber or onto the heating 
elements. This would inevitably cause the heating coils to malfunction during the next 
firing.  Should  the  firing  chamber/heating  elements  come  into  contact  with  a  foreign 
substance, eliminate the problem immediately, because burnt-on foreign substances 
can cause damage to the heating elements and the bricks. In the event of a serious 
incident, contact us or your local specialist dealer. 

 

Heating  coils  are  subject  to  wear.  Their  resistance  (ohm)  increases  with  each firing, 
and  with  time,  causes  a  delay  in  the  firing  curve  due  to  a  decline  in  performance, 
particularly  in  the  higher  temperature  range.  In  the  case  of  extreme  wear,  we 
recommend  replacing  all  of  the  heating  coils,  because  replacing  individual  heating 
coils can cause temperature differences within the kiln. 

 

Please note

: Previously fired heating coils are brittle and therefore prone to breaking 

(not a warranty claim). Therefore, a subsequent correction to the heating coils should 
be avoided! 

 

Good to know:

 

 

Factors that affect the lifespan of a heating coil: 

 

• 

The  interior  kiln  atmosphere:  e.g.,  aggressive  materials.  Good  ventilation  is 
particularly  important  for  materials  containing  solvents,  heavy  sulphur  or 
fluoride. 

Содержание B 200

Страница 1: ...Operating Manual Electric Kiln B 200 ...

Страница 2: ...2 3 Power source information RC device 5 2 4 Firing with the kiln 6 3 General operating information 7 3 1 Operating the control unit 7 3 2 Entering program Starting program 7 3 3 The exhaust air hole 10 3 4 The air intake opening 10 3 5 Proper handling during firing 11 4 Maintenance care and cleaning 12 5 Trouble shooting tips 13 5 1 The control unit 13 5 2 The combustion chamber 13 6 Warranty obl...

Страница 3: ...y information in its entirety prior to starting up the shuttle kiln Keep the operating instructions in a safe place for future reference 1 2 Safety Information Caution Hot surface Do not open when kiln is hot Caution Disconnect the kiln from the mains prior to opening the electric panel Caution Voltage carrying components Risk of fatal injury The CE mark verifies that the conformity assessment pro...

Страница 4: ...rmation is observed In commercial enterprises the kiln and control unit must be inspected by a qualified electrician for proper and optimal functioning condition in accordance with BGV A3 German equipment testing procedure prior to start of operation and every 4 years Repairs and maintenance procedures on electric components may only be carried out by a qualified electrician For safety reasons the...

Страница 5: ...here must be at least 50 cm of space between all sides of the kiln and the walls The floor ceiling insulation walls dividing walls covers etc must be made of heavy duty inflammable materials Ensure that the assembly site is well ventilated Otherwise an exhaust unit must be installed In all cases a ventilation technician must be consulted 2 3 Power source information RC device To operate the kiln i...

Страница 6: ...ry for firing ceramic diesel particle filters The preheating phase takes approx 1 hour during which the temperature is increased up to 550 C with a subsequent holding time of 3 5 or 8 hours Therefore the firing time without the cooling phase takes either 4 6 or 9 hours The temperature for ceramic filters may not exceed 550 C ...

Страница 7: ...nal temperature Button Description Display To access the USER menu press the P button USER appears in the green display Button Description Display To access the set temperature menu item press the P button again SET appears in the green display Button Description Display To activate the set temperature menu item press the P a third time SET flashes in the green display ...

Страница 8: ...To save the entered program values press the P button Entering program set value of gradient Button Description Display To access the gradient menu item press the button rA appears in the display Button Description Display To activate the gradient menu item press the P button rA is flashes in the display Button Description By pressing the button you can increase the gradient value and with the but...

Страница 9: ...re with the aid of the time selector switch 3 h position Holding time of final temperature is 3 hours 5 h position Holding time of final temperature is 5 hours 8 h position Holding time of final temperature is 8 hours Starting stopping the program The firing program is started by pushing the Exit F button The program is stopped by pushing the button once again ...

Страница 10: ...ey stone included in delivery Caution Do not look directly into the exhaust air hole when the kiln is hotter than 150 C This can cause injury to the face Operating personnel must wear adequate protective clothing Baumot GmbH will not accept liability for personal injury or material damage ...

Страница 11: ...ar the kiln Unauthorised persons should not be permitted to remain in the area Caution The loading process may only be carried out by trained employees Use suitable loading aids to facilitate the loading process Caution In the event of an unforeseen incident take appropriate safety measures if the kiln has to be opened at high temperatures Operating personnel must wear adequate protective clothing...

Страница 12: ...ts and the bricks In the event of a serious incident contact us or your local specialist dealer Heating coils are subject to wear Their resistance ohm increases with each firing and with time causes a delay in the firing curve due to a decline in performance particularly in the higher temperature range In the case of extreme wear we recommend replacing all of the heating coils because replacing in...

Страница 13: ...es in the junction box of the kiln They must be protected with T 2A 5 2 The combustion chamber is not heating up or is kiln is heating up very slowly Check if the cover of the kiln is completely closed It is possible that the safety switch is not closing the safety circuit The set temperatures are not achieved The control unit is indicating an error Examine the heating conductor for signs of break...

Страница 14: ...amages caused by improper handling Please note The lightweight refractory bricks used in the brick lining are subject to severe temperature fluctuations This can cause cracking in the brick lining This is normal and does not interfere with the function of the shuttle kiln They are therefore also not cause for a complaint What to do in a warranty case or in case of damage Inform your local speciali...

Страница 15: ... listed in this operating manual are not specifically indicated because they are commonly known These names and designations can however be the property of companies or institutes 8 SERVICE ADDRESSES If you have questions regarding your kiln replacement parts or additional accessories please contact your specialist dealer or Baumot GmbH We wish you much success and only good firing results Your Ba...

Отзывы: