1. Using the numerical buttons ( ) enter the
desired batch size; one, two or three digits (maximum
setting is 999).
2. Using the
“+”
and
”-“
buttons, enter the desired
feed interrupt time (0.3 to 9.9 seconds). This gives the
separation.
When stop is displayed, pressing the “
SHEET START
”
button will feed a batch and stop. Press the “
SHEET
START
” button to process the next batch.
11.3 Resetting the batch count.
To reset the batch counters press the
“RESET”
but-
ton, then press the
“SET BATCH”
button. This will reset
the batch count and the total batches. The Total Count will
not be reset.
11.4 Rate
The
“RATE”
button is used to display the average
pieces per hour, both current and average since the last total
counter reset.
Pressing the
“RATE”
button will change the display
to the rate screen consisting of two lines. The top line is the
current rate. It will have a 5 digit display, and will refresh
every 6 seconds. The second line will show the average
pieces per hour since the last total counter reset. This line
will also have a 5 digit display, and refresh every 30 sec-
onds.
The display will stay in this mode until another mode
button is pressed. The
“ENTER”
and
“RESET”
buttons
will have no affect in this mode.
NOTE:
Every time the total count is reset the
average rate per hour will also be reset.
NOTE:
If a button is not pressed within 2 minutes the
machine will return to the operating mode.
SET BATCH
### #.#
TOTAL COUNT #######
BATCH ### #####
CURRENT RATE #####
AVERAGE RATE #####