28
7.3
Acquisition Modes and Timings
The image acquisition consists of two separate, successively processed components.
Exposing the pixels on the photosensitive surface of the sensor is only the first part of the
image acquisition. After completion of the first step, the pixels are read out.
Thereby the exposure time (t
exposure
) can be adjusted by the user, however, the time need-
ed for the readout (t
readout
) is given by the particular sensor and image format.
Baumer cameras can be operated with differtent acquisition modes, the
Continuous
Mode (Free Running Mode)
, the
Acquisition Frame Rate Mode,
the
Single Frame Mode,
the
Multi Frame Mode
and the
Trigger Mode
.
The cameras can be operated non-overlapped
1)
or overlapped. Depending on the mode
used, and the combination of exposure and readout time:
Non-overlapped Operation
Overlapped Operation
Here the time intervals are long enough
to process exposure and readout succes-
sively.
Notice
Applies for cameras with Rolling
Shutter sensor
The Acquisition Mode
Non-Overlapped
Operation
is only available in Trigger
Mode.
In this operation the exposure of a frame
(n+1) takes place during the readout of
frame (n).
Notice
Applies for cameras with Rolling
Shutter sensor
The Acquisition Mode
Overlapped Op-
eration
is only available in Free Running
Mode.
Exposure
Readout
Exposure
Readout
7.3.1 Continuous Mode (Free Running Mode)
In the "Free Running" mode the camera records images permanently and sends them to
the PC. In order to achieve an optimal result (with regard to the adjusted exposure time
t
exposure
and image format) the camera is operated overlapped.
In case of exposure times equal to / less than the readout time (t
exposure
≤ t
readout
), the maxi-
mum frame rate is provided for the image format used. For longer exposure times the
frame rate of the camera is reduced.
Exposure
Readout
Exposure-
Active
t
exposure(n)
t
Exposure-
Active(n)
t
ExposureDelay
t
Exposure-
Active(n+1)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
t
ExposureActive
= t
exposure
1)
Non-overlapped means the same as sequential.
Image parameters:
Offset
Gain
Mode
Partial Scan
Timings:
A - exposure time
frame (n) effective
B - image parameters
frame (n) effective
C - exposure time
frame (n+1) effective
D - image parameters
frame (n+1) effective
Содержание VEXG
Страница 2: ...2 ...
Страница 39: ...39 8 1 2 3 Pixel Formats VEXU Camera Type Mono8 Mono12 Bayer RG8 Bayer RG12 Monochrome VEXU 24M Color VEXU 24C ...