23
Baumer_MHGP400_II_DE-EN (19A2)
MB212 - 11105828
4
Montage
/ Mounting
8
Technical data
8
Technical data
8.1
Technical data - electrical ratings
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE
UL approval / E217823
8.2
Technical data - electrical ratings (square-wave)
•
Voltage supply (Signals):
R
N...C: 4.5...30 VDC
(TTL/RS422)
T
N...C: 5 VDC ±5 %
(TTL/RS422)
H
N...C: 10...30 VDC
(HTL)
U
N...C: 5...30 VDC
(TTL/HTL)
4)
•
Consumption w/o load:
≤160 mA
•
Pulses per revolution:
256...524288 (as ordered)
•
Phase shift:
90° ±10°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Magnetic
•
Output frequency:
≤2 MHz
•
Output signals:
A+, B+, R+, A−, B−, R−
•
Output stages:
HTL
TTL/RS422
(as ordered)
8.3
Technical data - electrical ratings (SinCos)
•
Voltage supply (Signals):
P
N...C: 4.5...30 VDC
•
Consumption w/o load:
≤160 mA
•
Sinewave cycles per turn:
256...32768 (as ordered)
•
Phase shift:
90° ±5
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Magnetic
•
Output signals:
A+, B+, R+, A−, B−, R−
•
Output stage:
SinCos 1 Vpp
•
Difference of SinCos amplitude:
≤20 mV
•
Harmonics typ.:
-40 dB
•
DC offset:
≤20 mV
•
Bandwidth:
400 kHz (-3 dB)
4)
At UB = 5 VDC: TTL/RS422; At UB = 10...30 VDC: HTL