ELECTRICAL CONNECTION / SPEED SWITCH (OPTION) - SWITCHING CHARACTERISTICS
17/29
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
5.6
Speed switch (option) - switching characteristics
i
The factory setting of the switching speed for the PMG10
P
is 6000 rpm� The PMG10
without programming interface is delivered with the individually ordered fixed swit-
ching speed�
Event
State of the speed switch output
During initialisation
High resistance (overspeed)
After initialisation and
speed ≤ -ns (off)
High resistance (overspeed)
-ns (off) < speed ≤ -ns (on)
State unchanged
Low resistance (no overspeed) after initialisation if
the device is rotating between the switching range
during initialisation�
-ns (on) < speed < +ns (on)
Low resistance (no overspeed)
+ns (on) ≤ speed < +ns (off)
State unchanged
Low resistance (no overspeed) after initialisation if
the device is rotating between the switching range
during initialisation�
+ns (off) ≤ speed
High resistance (overspeed)
n
= Speed
+ns
(off)
= Switch-off speed at shaft rotation in positive rotating direction*
-ns
(off)
= Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis : 5...100 % (factory setting = 10 % min. 1 Digit)
+ns
(on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns
(on) = Switch-on speed at shaft rotation in negative rotating direction*
Low resistance
Resistance between
SP+ and SP-
High resistance
-ns (on)
0
+ns (on)
-n
+n
-ns (off)
+ns (off)
* See
�
Содержание Hubner PMG10