MB051a - 11102670
Baumer_EEXOG9S_II_DE-EN (19A2)
24
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
•
Voltage supply:
5 VDC ±5 % (version DN ...)
9...30 VDC (version DN ... R)
•
Consumption w/o load:
≤90 mA
•
Sinewave cycles per turn:
1024...2048 (as ordered)
•
Phase shift:
90°
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output signals:
K1, K2, K0 + inverted
•
Output stage:
SinCos 1 Vpp
•
Difference of SinCos amplitude:
≤20 mV
•
Harmonics typ.:
-50 dB
•
DC offset:
≤20 mV
•
Bandwidth:
250 kHz (-3 dB)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approval:
CE
10.2
Technical data - mechanical design
•
Size (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft
•
Admitted shaft load:
≤200 N axial
≤350 N radial
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP56
•
Operating speed:
≤6000 rpm (T5, mechanical)
≤4500 rpm (T6, mechanical)
•
Operating torque typ.:
4 Ncm
•
Rotor moment of inertia:
290 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Ambient temperature:
-20...+55 °C
•
Resistance:
IEC 60068-2-6
Vibration 10 g, 50-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
•
Corrosion protection:
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
•
Explosion protection:
II 2 G Ex db eb IIC T5/T6 Gb
Ex db eb IIC T5/T6 Gb
•
Connection:
Terminal box
•
Weight approx.:
3.5 kg