SETUP
MB112EN - 11185046, 19A1, Baumer_HENQ1100_OI_EN 6/32
In order to increase the operating time, a HENQ 1100 that is fitted with the accumulator op
-
tion can be switched off by the On/Off switch�
If the HENQ 1100 is connected to the plug-in power supply, then the On/Off switch changes
it from charging mode (no display indication, display lighting is inactive) to measurement
mode and back again� On a HENQ 1100 without the accumulator option, the On/Off switch
has no function�
The accumulator is not charged up in measurement mode�
In accumulator operation, the encoder can still be supplied from the HENQ 1100, whereby
the current consumption of the encoder will decisively influence the operating time.
5.5
Entering the encoder data (menu
)
The HENQ 1100 makes provision for the attachment of any encoder with TTL (RS422),
HTL or SinCos output signals�
The encoder data are entered in menu
as follows:
If the device is used in conjunction with encoders from Baumer Hübner, then the appro-
priate type (
1
-
40
) can be selected in the menu item
ENCODER
�
Because of the large number of Baumer Hübner encoder types, the field for selection is
restricted to the most common models available at present� When the encoder type has
been selected, the parameters
MaxSpeed
,
inv.Sig.
,
ZeroPuls
,
with K2
,
RefLevel
and
Pulse-No
are displayed for checking�
If your encoder is not present in the selection menu, select ‘
0
, in the menu item
ENCODER
� Then you can set the encoder parameters th-
rough the menu items
inv.Sig.
,
ZeroPuls
,
with K2
,
RefLevel
and
Pulse-No
, see
, individually by hand�
It is also possible to edit the encoder database by using the ”config“ key, see
� In the following submenu, the parameters encoder name
#############
,
MaxSpeed
,
inv.Sig.
,
ZeroPuls
,
with K2
,
RefLevel
and
Pulse-No
can be set
individually�
5.6
Measuring the encoder supply (menu
)
After connecting up a incremental encoder, it is recommended to check the supply to the
encoder, see
�
For this purpose, the HENQ 1100 offers the option in menu
of displaying the supply
voltages present at the encoder connection (5 V and 9���30 V), the current drawn (in mA)
and the power consumption (in mW)�
This makes it easy to detect wiring errors, such as a short-circuit or cable break, or an
encoder fault�
The current drawn by the output driver that is integrated in the HENQ 1100 is shown in
the last line of the display� This will only be non-zero if the encoder signals provided by