OPERATION / MENU DESCRIPTION
MB112EN - 11185046, 19A1, Baumer_HENQ1100_OI_EN 16/32
Fig.3:
Display menu
picture 2
Fig.4:
Display menu
picture 3
PhaseErr
:
##
Threshold value for the phase shift
Output
:
on
/
off
The output driver can be switched off if
required
INT/EXT
:
INT
/
EXT
INT
= Encoder power supplied via HENQ
1100
EXT
= External supply for the encoder
Backlite
:
on
/
off
Background lighting on/off
inv.Sig.
:
yes
/
no
Inverted signals yes/no
ZeroPuls
:
yes
/
no
Reference signal yes/no
with K2
:
yes
/
no
K2 yes/no
Fig.5:
Display menu
picture 4a
Fig.6:
Display menu
picture 4b
RefLevel
:
TTL
/
HTL
/
SIN
Reference level and level for output driver
(TTL → TTL; HTL → HTL; SIN → TTL)
If „
RefLevel
=
SIN
“ is selected, the output
simulates a TTL source�
Pulse-No
:
#####
Number of pulses
ENCODER
:
#
Encoder database (
#
=
1
-
40
: predefined
Baumer Hübner encoder types;
#
=
0
: user
setting)
Submenu
ENCODER
see
�
HOG 10 DN 1024I
Encoder name from encoder database, see
User Setting
Encoder name user setting, see