SAFETy AND ATTENTION INSTRUCTIONS
MB245EN - 11171693, 16A1, Baumer_PMG10-SSI_II_EN
4/25
2.2
Attention instructions for mounting and operation
)
Risk of destruction due to electrostatic charge
Electronic parts contained in the encoder are sensitive to high voltages�
» Do not touch plug contacts or electronic components�
» Protect output terminals against external voltages�
» Do not exceed max� operating voltage�
)
Risk of destruction due to mechanical overload
Rigid mounting may give rise to constraining forces�
» Never restrict the freedom of movement of the encoder� The installation instruc-
tions must be followed�
»
It is essential that the speciied clearances and/or angles are observed.
)
Risk of destruction due to mechanical shock
Violent shocks, e� g� due to hammer impacts, can lead to the destruction of the
sensing system�
» Never use force� Assembly is simple when correct procedure is followed�
» Use suitable puller for disassembly�
)
Risk of destruction due to contamination
Dirt penetrating inside the encoder can cause short circuits and damage the optical
sensing system�
» Absolute cleanliness must be maintained when carrying out any work on the open
terminal box�
» When dismantling, never allow lubricants to penetrate the encoder�
)
Risk of destruction due to adhesive luids
Adhesive luids can damage the optical sensing system and the bearings. Dismoun
-
ting an encoder, secured to a shaft by adhesive may lead to the destruction of the
unit�
»
Do not use adhesive luids for ixing.