background image

 

IMPORTENT NOTES

MB245EN - 11171693, 16A1, Baumer_PMG10-SSI_II_EN

 2/25

1.4 

Maintenance and lifetime

The encoder may be only opened as described in this instruction� Repair or maintenance 
work that requires opening the encoder completely must be carried out by the manufactu-
rer�

Alterations of the device are not permitted�

The expected operating life of the device depends on the ball bearings, which are equipped 
with a permanent lubrication�

In the event of queries or subsequent deliveries, the data on the device type label must be 
quoted, especially the type designation and the serial number�

1.5 

Approvals and warranty

EU Declaration of Conformity meeting to the European Directives�

We grant a 2-year warranty in accordance with the regulations of the Central Association of 
the German Electrical Industry (ZVEI)�

 

i

warranty seal   
Damaging the warranty seal on the encoder invalidates warranty�

1.6 

Storage temperature and disposal

The storage temperature range of the encoder is between -15���+70 °C (caused by pa-
cking)�

Encoder components are to be disposed of according to the regulations prevailing in the 
respective country�

Содержание Hubner Berlin PMG 10-SSI

Страница 1: ...PMG 10 SSI Absolute encoder with magnetic sensing MB245EN 11171693 16A1 Baumer_PMG10 SSI_II_EN Installation and operating instructions...

Страница 2: ...ed accessory for mounting not included in scope of delivery 6 3 3 Required tools not included in scope of delivery 6 4 MOUNTING 7 4 1 Mounting the spring disk couling to the encoder 7 4 2 Mounting to...

Страница 3: ...ditonal output 2 16 5 7 Version with radial lange connectors 17 5 7 1 Cable connection mating connector M23 accessory 17 5 7 2 Assignment lange connectors 18 5 7 2 1 First lange connector C SSI withou...

Страница 4: ...ing instruction The customer must check the suitability for the purpose intended Mounting and selection must be executed by authorized and qualiied personnel Moun ting electrical commissioning or any...

Страница 5: ...es or subsequent deliveries the data on the device type label must be quoted especially the type designation and the serial number 1 5 Approvals and warranty EU Declaration of Conformity meeting to th...

Страница 6: ...rts can cause extremely serious injuries Before all work switch off all operating voltages and ensure machinery is statio nary Prevent reconnection operating voltages by third parties Risk of serious...

Страница 7: ...eciied clearances and or angles are observed Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing system Never use force Asse...

Страница 8: ...ry 1 Housing 2 EURO lange B10 3 Solid shaft with key 4 Bearing shield 5 LED function indicators Radial terminal boxes see section 5 A SSI additional output 1 B Speed switch additional output 2 Radial...

Страница 9: ...and respective mating connectors are required for the electrical connection Details see section 5 page 11 3 3 Required tools not included in scope of delivery 2 5 mm 10 und 22 mm TX 10 TX 20 6 Instal...

Страница 10: ...ouplings are used pay attention to manufactu rer s notes 4 2 Mounting to drive shaft Lifetime restrictions and angle error by radial deviations High runout of the drive shaft can cause encoder angle e...

Страница 11: ...8 MOUNTING MOUNTING THE SPRING DISK COULING TO DRIVE SHAFT MB245EN 11171693 16A1 Baumer_PMG10 SSI_II_EN 8 25 4 3 Mounting the spring disk couling to drive shaft Mt 2 3 Nm 2 5 mm...

Страница 12: ...ut axial loading The encoder must be mounted on the drive with the least possible angular error and parallel misalignment Risk of damaging the ball bearings Coupling components must not be driven onto...

Страница 13: ...g for example ROTEX Incorrect mounting of the jaw type coupling can damage the encoder Avoid blocking of both coupling halves claws pressed together The encoder shaft must not subjected to direct axia...

Страница 14: ...d R Zero pulse reference signal R_ Zero pulse inverted nE System OK error output nE_ System OK_ error output inverted PRE PRESET RESET DIR Rotating direction SP DSL_OUT1 speed switch Open Collector or...

Страница 15: ...ero pulse R Zero pulse At positive rotating direction Clock frequency 100 kHz 2 MHz Period T 0 5 10 s Time lag t1 0 25 5 s Monolop time t2 20 s internal n m Number of bits i For continous clocking the...

Страница 16: ...on State unchanged Low resistance no overspeed after initialisation if the encoder is rotating between the switching range during initialisation ns on speed ns on Low resistance no overspeed ns on spe...

Страница 17: ...cross section 1 5 mm2 Connecting terminal irst terminal box A See section 5 6 2 1 or section 5 6 2 2 Connecting terminal second terminal box B See section 5 6 2 3 or section 5 6 2 4 5 6 Version with...

Страница 18: ...of damage Please beware of possible voltage drop in long cable leads inputs and out puts 5 6 2 1 Connecting terminal irst terminal box A SSI without additional output 1 dnu SA dnu SB dnu dnu dnu dnu...

Страница 19: ...5 SP dnu dnu dnu dnu dnu dnu SP dnu dnu dnu dnu dnu dnu SP A A_ B B_ UB SP nE nE_ R R_ dnu dnu 5 6 2 3 Connecting terminal second terminal box B Speed switch without additonal output 2 5 6 2 4 Connect...

Страница 20: ...cessory To ensure the speciied protection of the device the correct cable diameter must be used Connecting cables and mating connectors are not in scope of delivery 27 mm 24 mm Hand tight Cable shield...

Страница 21: ...15 dnu 16 dnu 17 D _ PIN ASSIGNMENT 10 11 Internal shield 12 B 13 B_ 14 D 15 A 16 A _ 17 D _ 5 7 2 Assignment lange connectors Do not connect voltage supply to outputs Danger of damage Please beware...

Страница 22: ...nge connector D Speed switch without additional output 2 1 2 3 4 5 6 7 8 9 10 12 11 1 2 3 4 5 6 7 8 9 10 12 11 5 7 2 4 Second lange connector D Speed switch with additional output 2 PIN ASSIGNMENT 1 d...

Страница 23: ...MB245EN 11171693 16A1 Baumer_PMG10 SSI_II_EN 20 25 6 DIMENSIONS 6 1 With radial terminal boxes All dimensions in millimeters unless otherwise stated Positive rotating direction A B Speed switch Additi...

Страница 24: ...ECTORS 21 25 MB245EN 11171693 16A1 Baumer_PMG10 SSI_II_EN 6 2 With radial lange connectors All dimensions in millimeters unless otherwise stated Positive rotating direction Speed switch Additional out...

Страница 25: ...7 6 8 DISMOUNTING MB245EN 11171693 16A1 Baumer_PMG10 SSI_II_EN 22 25 7 DISMOUNTING 2 5 mm 10 mm...

Страница 26: ...e TTL RS422 Sensing method Magnetic Code Gray default or binary Code sequence CW CCW programmable CW default Input signals SSI clock PRESET rotating direction Interference immunity EN 61000 6 2 Emitte...

Страница 27: ...tia 1 kgcm2 Admitted shaft load 450 N axial 650 N radial Materials Housing aluminium alloy Shaft stainless steel Operating temperature 40 85 C Relative humidity 95 non condensing Resistance IEC 60068...

Страница 28: ...Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion MB245EN 11171693 16A1 05 07 2016 Baumer_PMG10 SSI_II_EN Original language of this instruction i...

Отзывы: