Technical data
PMG10
Electrical Data
Operating voltage Ub
10-30 V DC (Ub (Bus))
4,75-30 V DC (Ub (Ink))
Short-circuit proof
Yes
Operating current without load
≤ 200 mA
Initializing time
≤ 500 ms after switch-on
Sensing principle
Magnetic
Fieldbus interface
Profibus DPV0/V2
Data rate (fieldbus)
9,6-12000 kBaud
User address
Rotary switch inside the bus terminal box
Steps per turn
8192 / 13 Bit
Number of turns
65536 / 16 Bit
Incremental output
Rectangle TTL/HTL, TTL/RS422
Interference immunity
see data sheet and declaration of conformity
Interference emission
see data sheet and declaration of conformity
Programming interface
RS485 (≤ 600 m)
I
Programmable parameters
Bus system (see reference at the end of the
chapter)
Additional output (ppr number)
I
Switch off / on speed
I
Diagnostic functions
Position and parameter errors
LED status indicator
DUO LED inside the bus terminal box
4 LEDs at rear of the device
Approvals
see data sheet and declaration of conformity
Electrical data (Speed switch)
Switching accuracy
±2 % (or 1 digit)
Switching outputs
1 output
(Open-collector
II
or semiconductor relay
II
)
Output switching performance
30 V DC; ≤ 100 mA
Switching delay
≤ 20 ms
Mechanical
Dimensions (flange)
ø 115 mm
Shaft type
ø 11 mm solid shaft
Flange
EURO flange B10
Protection class DIN EN 60529
IP66/IP67
Operating speed
≤6000 rpm
Switching speed range
ns (off) = ±2 ... ±6000 rpm,
(PMG10P: factory setting 6000 rpm)
Operating torque typically.
10 Ncm