background image

MB117 - 11055728

  Baumer_HOGS71_II_DE-EN (19A1) 

2

 

 General notes 

1

1

 

General notes  

1.1

 

Symbol guide:

 

 

Danger 

 

Warnings of possible danger

 

 

General information for attention 

 

Informations to ensure correct device operation

 

i

 

Information 

 

Recommendation for device handling

1.2

 The 

sine encoder HOGS 71 

is an opto electro nic 

precision measurement device

 which must 

be handled with care by skilled personnel only.

1.3

 

The expected 

service life

 of the device depends on the 

ball bearings

, which are equipped with 

a permanent lubrication.

1.4

 

The 

storage temperature range

 of the device is between -15 °C and +70 °C. 

 

1.5

 

The 

operating temperature range

 of the device is between -20 °C and +85 °C, 

restricted in potentially explosive environments, see section 2, 

measured at the housing.

1.6

 

EU Declaration of Conformity

 meeting to the European Directives.

1.7

 

The device is 

UL approved

 (not applicable for operation in potentially explosive atmospheres).

1.8

 

We grant a 

2-year warranty

 in accordance with the regulations of the ZVEI (Central Association 

of the German Electrical Industry).

1.9

 

Maintenance work

 is not necessary. The device may be only opened as described in this 

instruction. 

Repair work

 that requires opening the device completely must be carried out by the 

manufacturer

. Alterations of the device are not permitted. 

1.10

 

In the event of 

queries

 or 

subsequent deliveries

, the data on the device type label must be 

quoted, especially the type designation and the serial number.

1.11

 

Disposal (environmental protection):

 

Do not dispose of electrical and electronic equipment in household waste. The product 

contains valuable raw materials for recycling. Whenever possible, waste electrical and 

electronic equipment should be disposed locally at the authorized collection point. If 

necessary, Baumer gives customers the opportunity to dispose of Baumer products profession-

ally. For further information see www.baumer.com.

Warning!   

Damaging the seal  

  on the device invalidates warranty.

i

Содержание HUBNER BERLIN HOGS 71

Страница 1: ...HOGS 71 Sinus Drehgeber Sine encoder MB117 11055728 Baumer_HOGS71_II_DE EN 19A1 Montage und Betriebsanleitung Mounting and operating instructions...

Страница 2: ...Schritt 2 9 5 3 Schritt 2 Option Sonderdrehmomentst tze 10 5 4 Schritt 3 und 4 11 5 5 Schritt 5 12 5 6 Montagehinweis 12 6 Abmessungen 13 6 1 Standard 13 6 2 Option Sonderdrehmomentst tze 13 7 Elektri...

Страница 3: ...ep 2 9 5 3 Step 2 Option special torque bracket 10 5 4 Step 3 and 4 11 5 5 Step 5 12 5 6 Mounting instruction 12 6 Dimensions 13 6 1 Standard 13 6 2 Option special torque bracket 13 7 Electrical conne...

Страница 4: ...tserkl rung gem den europ ischen Richtlinien 1 7 Das Ger t ist zugelassen nach UL gilt nicht f r Einsatz in explosionsgef hrdeten Bereichen 1 8 Wir gew hren 2 Jahre Gew hrleistung im Rahmen der Bedin...

Страница 5: ...operation in potentially explosive atmospheres 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German Electrical Industry 1 9 Maintenance work...

Страница 6: ...mm nicht berschreitet gem EN 60079 14 2 3 Eine gegebenenfalls an anderen Stellen aufgef hrte UL Listung gilt nicht f r den Einsatz im Ex Bereich 2 4 Das Ger t darf nur in Betrieb genommen werden wenn...

Страница 7: ...does not exceed a thickness of 5 mm in accordance with EN 60079 14 2 3 An UL listing that may be stated elsewhere is not valid for use in explosive environ ments 2 4 Operation of the device is only p...

Страница 8: ...orgegebenen Abst nde und oder Winkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals Gew...

Страница 9: ...tial that the specified clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing system...

Страница 10: ...mm ISO 4762 mit Schraubensicherung 12 Ejot SF Schraube M4x14 mm 13 Anschlussklemmen siehe Abschnitt 7 3 14 Kabelverschraubung PG 9 11 f r Kabel 5 10 mm 1 Je nach Version 1 Housing 2 Blind hollow shaft...

Страница 11: ...r erh ltlich siehe Abschnitt 7 4 15 Sensor cable HEK 8 available as accessory see section 7 4 15 5 Montage 5 1 Schritt 1 5 Mounting 5 1 Step 1 4 3 Erforderliches Werkzeug nicht im Lieferumfang enthal...

Страница 12: ...einen Rundlauffehler aufwei sen da dieser zu einem Winkelfehler f hren kann Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less...

Страница 13: ...le sollte einen m g lichst kleinen Rundlauffehler aufwei sen da dieser zu einem Winkelfehler f hren kann Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The dr...

Страница 14: ...Cable shield Ansicht X siehe Abschnitt 7 3 View X see section 7 3 13 15 Siehe Seite 7 oder 8 See page 7 or 8 17 mm Zur Gew hrleistung der angegebenen Schutzart sind nur geeignete Kabel durchmesser zu...

Страница 15: ...instruction 10 11 3 mm Zul Anzugsmoment Max tightening torque Mt 2 3 Nm Siehe Seite 7 See page 7 Wir empfehlen das Ger t so zu mon tieren dass der Kabelanschluss kei nem direkten Wassereintritt ausge...

Страница 16: ...momentst tze 73186 6 Dimensions 6 1 Standard 73184 6 2 Option special torque bracket 73186 Drehrichtung positiv Positive rotating direction Drehrichtung positiv Positive rotating direction dH7 12H7 14...

Страница 17: ...l 1 V 1 V 0 4 V A A Cos Sin 0 5 V 2 5 V A A B B C C UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsanschluss Geh use Earth ground housing A K1 A Ausgangssignal Kanal 1 Output s...

Страница 18: ...al cables from power cables Cable terminating resistance 120 7 Elektrischer Anschluss Electrical connection Aderendh lsen benutzen Use core end ferrules Rot Red UB Wei White A Braun Brown A Gr n Green...

Страница 19: ...7 11055728 Baumer_HOGS71_II_DE EN 19A1 16 Demontage Dismounting 8 8 Demontage 8 1 Schritt 1 8 Dismounting 8 1 Step 1 8 2 Schritt 2 8 2 Step 2 10 11 3 mm 17 mm 13 14 15 Siehe Seite 7 oder 8 See page 7...

Страница 20: ...17 Baumer_HOGS71_II_DE EN 19A1 MB117 11055728 8 Demontage Dismounting 8 3 Schritt 3 8 3 Step 3 3 4 3 mm 3 mm Siehe Seite 7 See page 7 3 9 7 5 mm 3 mm...

Страница 21: ...MB117 11055728 Baumer_HOGS71_II_DE EN 19A1 18 8 4 Schritt 4 8 4 Step 4 8 5 Schritt 5 8 5 Step 5 Demontage Zubeh r Dismounting Accessories 8 9 3 mm 10 11 Siehe Seite 7 See page 7...

Страница 22: ...festigkeit EN 61000 6 2 St raussendung EN 61000 6 3 Zulassungen CE UL Zulassung E256710 9 2 Technische Daten mechanisch Baugr e Flansch 60 mm Wellenart 12 14 mm einseitig offene Hohlwelle Zul ssige We...

Страница 23: ...Emitted interference EN 61000 6 3 Approvals CE UL approval E256710 9 2 Technical data mechanical design Size flange 60 mm Shaft type 12 14 mm blind hollow shaft Admitted shaft load 30 N axial 40 N rad...

Страница 24: ...EAG 151 HEAG 154 Fiber optic links HEAG 171 HEAG 176 Digital speed switch DS 93 Analyzer for encoders HENQ 1100 10 Zubeh r Sensorkabel f r Drehgeber HEK 8 Werkzeugset Bestellnummer 11068265 Digital Ko...

Страница 25: ...2011 Standard s EN 60079 0 2012 A11 2013 EN 60079 15 2010 EN 60079 31 2014 Norme s EN 50581 2012 Ort und Datum Berlin 15 08 2016 Unterschrift Name Funktion Daniel Kleiner Place and date Signature nam...

Страница 26: ...Baumer_HOGS71_II_DE EN 19A1 MB117 11055728...

Страница 27: ...MB117 11055728 Baumer_HOGS71_II_DE EN 19A1...

Страница 28: ...GmbH P O Box 12 69 43 10609 Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion Originalsprache der Anleitung ist Deutsch Technische nderungen vorbe...

Отзывы: