background image

MB118T1 - 11091890

  Baumer_HOGS151-T1_II_DE-EN (19A1) 

6

 

 Security indications 

3

3

 

Security indications  

3.1

 

Risk of injury due to rotating shafts

 

Hair and clothes may become tangled in rotating shafts.

• 

Before all work switch off all voltage supplies and ensure machinery is stationary.

3.2

 

Risk of destruction due to electrostatic charge

 

Electronic parts contained in the device are sensitive to high voltages.

• 

Do not touch plug contacts or electronic components.

• 

Protect output terminals against external voltages.

• 

Do not exceed maximum voltage supply.

3.3

 

Risk of destruction due to mechanical overload

 

Rigid mounting may give rise to constraining forces.

• 

Never restrict the freedom of movement of the device.  

The mounting instructions must be followed.

• 

It is essential that the specified clearances and/or angles are observed.

3.4

 

Risk of destruction due to mechanical shock

 

Violent shocks, e. g. due to hammer impacts, can lead to the destruction of the sensing system.

• 

Never use force.  

Mounting is simple when correct procedure is followed.

• 

Use suitable puller for dismounting.

3.5

 

Risk of destruction due to contamination

 

Dirt penetrating inside the device can cause short circuits and damage the sensing system.

• 

Absolute cleanliness must be maintained when carrying out any work on the device.

• 

Never allow lubricants to penetrate the device.

3.6

 

Risk of destruction due to adhesive fluids

 

Adhesive fluids can damage the sensing system and the ball bearings. Dismounting a device, 

secured to a shaft by adhesive may lead to the destruction of the device.

3.7

 

Explosion risk

 

You can use the device in areas with explosive atmospheres of category 3 D and 3 G. The opera-

tion in other explosive atmospheres is not permissible.

Содержание Hubner Berlin HOGS 151

Страница 1: ...MB118T1 11091890 Baumer_HOGS151 T1_II_DE EN 19A1 HOGS 151 Sinus Drehgeber Sine encoder Montage und Betriebsanleitung Mounting and operating instructions...

Страница 2: ...ritt 3 10 5 1 4 Schritt 4 10 5 2 Mit Klemmring 11 5 2 1 Schritt 1 11 5 2 2 Schritt 2 11 5 2 3 Schritt 3 12 5 2 4 Schritt 4 12 5 3 Montagehinweis 13 5 4 Option Sperrluftanschluss 13 6 Abmessungen 14 6...

Страница 3: ...tep 4 10 5 2 With clamping ring 11 5 2 1 Step 1 11 5 2 2 Step 2 11 5 2 3 Step 3 12 5 2 4 Step 4 12 5 3 Mounting instruction 13 5 4 Option sealing air connection 13 6 Dimensions 14 6 1 With clamping se...

Страница 4: ...bschnitt 2 am Geh use gemessen 1 6 EU Konformit tserkl rung gem den europ ischen Richtlinien 1 7 Das Ger t ist zugelassen nach UL gilt nicht f r Einsatz in explosionsgef hrdeten Bereichen 1 8 Wir gew...

Страница 5: ...evice is UL approved not applicable for operation in potentially explosive atmospheres 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German E...

Страница 6: ...ew hrleisten dass eine m gliche Staubablagerung eine maxi male Schichtdicke von 5 mm nicht berschreitet gem EN 60079 14 2 4 Eine gegebenenfalls an anderen Stellen aufgef hrte UL Listung gilt nicht f r...

Страница 7: ...ge from 20 C to 40 C 2 3 The plant operator must ensure that any possible dust deposit does not exceed a thickness of 5 mm in accordance with EN 60079 14 2 4 An UL listing that may be stated elsewhere...

Страница 8: ...e vorgegebenen Abst nde und oder Winkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals...

Страница 9: ...sential that the specified clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing sys...

Страница 10: ...lemmring 1 8 Klemmringschraube M4x16 mm 1 ISO 4762 9 Anschlusskabel siehe Abschnitt 7 3 10 Option Rundsteckverbinder M23 siehe Abschnitt 7 4 1 Je nach Version 1 Housing 2 Through hollow shaft 3 Coupli...

Страница 11: ...s 12 Befestigungsschraube M4x10 mm ISO 4762 zur Befestigung des Kupplungsbleches 11 Washer A4 3 ISO 7089 to fix the coupling plate 12 Fixing screw M4x10 mm ISO 4762 to fix the coupling plate 11 12 4 3...

Страница 12: ...nn Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in an angle error R...

Страница 13: ...N 19A1 10 Montage Mounting 5 Zul Anzugsmoment Max tightening torque Mt 1 Nm Siehe Seite 7 oder 8 See page 7 or 8 5 1 3 Schritt 3 5 1 4 Schritt 4 5 1 3 Step 3 5 1 4 Step 4 2 5 mm 5 4 Zul Anzugsmoment M...

Страница 14: ...ler f hren kann Rundlauffehler verursachen Vibratio nen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in an...

Страница 15: ...N 19A1 12 Montage Mounting 5 Zul Anzugsmoment Max tightening torque Mt 2 3 Nm Zul Anzugsmoment Max tightening torque Mt 3 4 Nm Siehe Seite 7 oder 8 See page 7 or 8 12 11 3 mm 3 mm 5 4 5 2 3 Schritt 3...

Страница 16: ...1 bar ber druck am Sperrluftanschluss betrie ben wird i i To achieve a protection of IP54 it is necessary to mount a maintenance equipment for compressed air see fig 1 so that the device is operating...

Страница 17: ...1 L nge und Konfektionierung wie bestellt Connecting cable see section 7 1 Length and conditioning as ordered Option Rundsteckverbinder M23 Option mating connector M23 Option Sperrluftanschluss Option...

Страница 18: ...ore end ferrules 7 Elektrischer Anschluss 7 1 Beschreibung der Anschl sse 7 Electrical connection 7 1 Terminal significance UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsansch...

Страница 19: ...d Ausg nge Do not connect voltage supply to outputs Danger of damage Please beware of possible voltage drop in long cable leads inputs and outputs 1 9 8 2 10 12 7 3 11 6 4 5 Ansicht X in Rundsteckverb...

Страница 20: ...er_HOGS151 T1_II_DE EN 19A1 MB118T1 11091890 8 Demontage Dismounting 8 2 Mit Klemmring Schritt 1 8 3 Schritt 2 8 2 With clamping ring Step 1 8 3 Step 2 Siehe Seite 7 oder 8 See page 7 or 8 12 11 3 mm...

Страница 21: ...7 A1 2011 Standard s EN 60079 0 2012 A11 2013 EN 60079 15 2010 EN 60079 31 2014 Norme s EN 50581 2012 Ort und Datum Berlin 15 08 2016 Unterschrift Name Funktion Daniel Kleiner Place and date Signature...

Страница 22: ...ussendung EN 61000 6 3 Zulassungen CE UL Zulassung E256710 10 2 Technische Daten mechanisch Baugr e Flansch 168 mm Wellenart 60 70 mm durchgehende Hohlwelle Zul ssige Wellenbelastung 350 N axial 500 N...

Страница 23: ...3 Approvals CE UL approval E256710 10 2 Technical data mechanical design Size flange 168 mm Shaft type 60 70 mm through hollow shaft Admitted shaft load 350 N axial 500 N radial Protection DIN EN 6052...

Страница 24: ...on is German Technical modifications reserved 11 Accessories Tool kit Order number 11068265 Interpolator HEAG 156 Precision Interpolator Splitter HEAG 158 Precision Sine Multiplier HEAG 159 Precision...

Отзывы: