background image

MB156a - 11069623

 Baumer_HOG100-R_DE_EN_202201_MI_11069623 (22A1)  

6

 

 Security indications 

3

3

 

Security indications  

3.1

 

Risk of injury due to rotating shafts

Hair and clothes may become tangled in rotating shafts.

 •

Before all work switch off all voltage supplies and ensure machinery is stationary.

3.2

 

Risk of destruction due to electrostatic charge

Electronic parts contained in the device are sensitive to high voltages.

 •

Do not touch plug contacts or electronic components.

 •

Protect output terminals against external voltages.

 •

Do not exceed maximum voltage supply.

3.3

 

Risk of destruction due to mechanical overload

Rigid mounting may give rise to constraining forces.

 •

Never restrict the freedom of movement of the device.  

The mounting instructions must be followed.

 •

It is essential that the specified clearances and/or angles are observed.

3.4

 

Risk of destruction due to mechanical shock

Violent shocks, e. g. due to hammer impacts, can lead to the destruction of the sensing system.

 •

Never use force.  

Mounting is simple when correct procedure is followed.

 •

Use suitable puller for dismounting.

3.5

 

Risk of destruction due to contamination

Dirt penetrating inside the device can cause short circuits and damage the sensing system.

 •

Absolute cleanliness must be maintained when carrying out any work on the device.

 •

Never allow lubricants to penetrate the device.

3.6

 

Risk of destruction due to adhesive fluids

Adhesive fluids can damage the sensing system and the ball bearings. Dismounting a device, 

secured to a shaft by adhesive may lead to the destruction of the device.

3.7

 

Explosion risk (only with option ATEX)

You can use the device in areas with explosive atmospheres of category 3 D and 3 G. The op-

eration in other explosive atmospheres is not permissible.

Содержание HOG 100

Страница 1: ...taler Drehgeber mit axialem Klemmendeckel Incremental encoder with axial terminal cover Montage und Betriebsanleitung Mounting and operating instructions MB156a 11069623 Baumer_HOG100 R_DE_EN_202201_M...

Страница 2: ...5 3 Schritt 3 Einseitig offene Hohlwelle 11 5 4 Schritt 3 Konuswelle 12 5 5 Schritt 4 13 5 6 Schritt 5 Drehmomentst tze 14 5 7 Hinweis zur Vermeidung von Messfehlern 15 5 8 Schritt 6 und 7 16 5 9 Schr...

Страница 3: ...10 5 2 Step 2 10 5 3 Step 3 Blind hollow shaft 11 5 4 Step 3 Cone shaft 12 5 5 Step 4 13 5 6 Step 5 Torque arm 14 5 7 How to prevent measurement errors 15 5 8 Step 6 and 7 16 5 9 Step 8 16 5 10 Mounti...

Страница 4: ...en nach UL gilt nicht f r Einsatz in explosionsgef hrdeten Bereichen 1 8 Wir gew hren 2 Jahre Gew hrleistung im Rahmen der Bedingungen des Zentralverbandes der Elektroindustrie ZVEI 1 9 Wartungsarbeit...

Страница 5: ...plicable for operation in potentially explosive atmospheres 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German Electrical Industry 1 9 Main...

Страница 6: ...icke von 5 mm nicht berschreitet gem EN 60079 14 2 3 Eine gegebenenfalls an anderen Stellen aufgef hrte UL Listung gilt nicht f r den Einsatz im Ex Bereich 2 4 Das Ger t darf nur in Betrieb genommen w...

Страница 7: ...dust deposit does not exceed a thickness of 5 mm in accordance with EN 60079 14 2 3 An UL listing that may be stated elsewhere is not valid for use in explosive environments 2 4 Operation of the devic...

Страница 8: ...rgegebenen Abst nde und oder Winkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals Gewa...

Страница 9: ...al that the specified clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing system N...

Страница 10: ...se zur Verbindung mit 13 15 Anschlussklemmen siehe Abschnitt 7 3 16 Verschlussstopfen 17 Kabelverschraubung M16x1 5 mm f r Kabel 5 9 mm 18 Zentrierstift f r Abdeckhaube 1 Housing 2 Blind hollow shaft...

Страница 11: ...ISO 7090 21c Selbstsichernde Mutter M6 ISO 10511 21d Zylinderschraube M6x8 mm f r Erdungsband ISO 1207 21e Scheibe B6 4 f r Erdungsband ISO 7090 1 K rzbar auf 71 mm 2 K rzbar auf 131 mm 19 Torque arm...

Страница 12: ...ery 22 Demontageset als Zubeh r erh ltlich Bestellnummer 11077087 bestehend aus 22a Gewindestift M6x10 mm ISO 7436 22b Zylinderschraube M8x45 mm ISO 4762 22 Dismounting kit available as accessory Orde...

Страница 13: ...ing 5 MB156a 11069623 Baumer_HOG100 R_DE_EN_202201_MI_11069623 22A1 10 5 Montage 5 1 Schritt 1 5 2 Schritt 2 5 Mounting 5 1 Step 1 5 2 Step 2 Siehe Seite 7 und 8 See page 7 and 8 19 9 8 6 7 10 11 10 m...

Страница 14: ...fehler f hren kann siehe Abschnitt 5 7 Rundlauffehler verursachen Vibra tionen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can...

Страница 15: ...7 Rundlauffehler verursachen Vibra tionen die die Lebensdauer des Ger tes verk rzen k nnen The drive shaft should have as less runout as possible because this can otherwise result in an angle error s...

Страница 16: ...11069623 5 5 Schritt 4 5 5 Step 4 Siehe Seite 7 oder 8 See page 7 or 8 5 4 21a 19 21c 21b 21b 21b 19 21b 21c Anzugsmoment einseitig offene Hohlwelle Tightening torque blind hollow shaft Mt 6 Nm Anzug...

Страница 17: ...e spielfrei erfolgen Ein Spiel von beispielsweise 0 03 mm entspricht einem Rundlauffehler des Ger tes von 0 06 mm was zu einem gro en Winkelfehler f hren kann siehe Abschnitt 5 7 The torque arm should...

Страница 18: ...Telefon Hotline 49 0 30 69003 111 5 7 How to prevent measurement errors To ensure that the device operates cor rectly it is necessary to mount it accu rately as described in section 5 1 to 5 6 which i...

Страница 19: ...Abschnitt 7 3 View X see section 7 3 Kabelschirm Cable shield 17 10 20 15 5 9 mm Zur Gew hrleistung der angegebenen Schutzart sind nur geeignete Kabel durchmesser zu verwenden To ensure the specified...

Страница 20: ...1069623 5 10 Montagehinweis 5 10 Mounting instruction i Wir empfehlen das Ger t so zu montieren dass der Kabelanschluss keinem direkten Wassereintritt ausgesetzt ist i It is recommended to mount the d...

Страница 21: ...6 2 Cone shaft 74150 74297 Abmessungen Dimensions 6 Um 90 versetzt gezeichnet Drawing 90 rotated Um 90 versetzt gezeichnet Drawing 90 rotated Drehrichtung positiv Positive rotating direction Drehricht...

Страница 22: ...g direction see section 6 UB Betriebsspannung Voltage supply 0V Masseanschluss Ground Erdungsanschluss Geh use Earth ground housing K1 Ausgangssignal Kanal 1 Output signal channel 1 K1 Ausgangssignal...

Страница 23: ...bschluss HTL 1 3 k TTL 120 7 4 Sensor cable HEK 8 accessory Baumer H bner sensor cable HEK 8 is recommended As a substitute a shielded twisted pair cable should be used Continuous wiring without any s...

Страница 24: ...I_11069623 22A1 MB156a 11069623 8 Demontage Dismounting 8 Demontage 8 1 Schritt 1 Elektrische Verbindung trennen 8 Dismounting 8 1 Step 1 Disconnect electrical connection 11 10 20 17 Siehe Seite 7 ode...

Страница 25: ...Baumer_HOG100 R_DE_EN_202201_MI_11069623 22A1 22 Demontage Dismounting 8 8 2 Schritt 2 8 3 Schritt 3 8 2 Step 2 8 3 Step 3 21d 21e 21c 21a 21b 19 4 5 Siehe Seite 7 oder 8 See page 7 or 8 12 10 mm 17 m...

Страница 26: ...HOG100 R_DE_EN_202201_MI_11069623 22A1 MB156a 11069623 8 Demontage Dismounting 8 4 Schritt 4 8 4 Step 4 8 5 Schritt 5 8 6 Schritt 6 8 5 Step 5 8 6 Step 6 Siehe Seite 8 See page 8 22a 22a 22b 0 8x4 mm...

Страница 27: ...1 HEAG 154 Fiber optic links HEAG 171 HEAG 176 Digital speed switch DS 93 Analyzer for encoders HENQ 1100 9 Zubeh r Drehmomentst tze Gr e M6 Bestellnummer siehe Abschnitt 4 3 Montageset f r Drehmoment...

Страница 28: ...E217823 10 2 Technische Daten mechanisch Baugr e Flansch 105 mm Wellenart 16 mm einseitig offene Hohlwelle 17 mm Konuswelle 1 10 je nach Bestellung Zul ssige Wellenbelastung 450 N axial 600 N radial S...

Страница 29: ...chnical data mechanical design Size flange 105 mm Shaft type 16 mm blind hollow shaft 17 mm cone shaft 1 10 as ordered Admitted shaft load 450 N axial 600 N radial Protection EN 60529 IP66 Operating s...

Страница 30: ...Baumer_HOG100 R_DE_EN_202201_MI_11069623 22A1 MB156a 11069623...

Страница 31: ...MB156a 11069623 Baumer_HOG100 R_DE_EN_202201_MI_11069623 22A1...

Страница 32: ...30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion Baumer_HOG100 R_DE_EN_202201_MI_11069623 22A1 31 01 2022 MB156a 11069623 Originalsprache der Anleitung ist Deutsch Technis...

Отзывы: