Baumer_BUDE-PROFINET_MA_EN.docx
37/41
www.baumer.com
14.06.2016 / bja
6.4.17. Parameter 61004: Subnet Mask of Station
Read:
This parameter is to read the subnet mask of the encoder-connected network.
Parameter 61004
Type Read only
Data type UINT32 (0x07)
Value range: 0.0.0.0 to 255. 255. 255. 255.
Data: 61004 [0] Subnet mask
6.4.18. Parameter 65000: Preset Value
A preset operation in data format of PROFIdrive profile telegrams 81 to 83 will reset the encoder
position to the preset value. Parameter format is „signed 32bit“, since relative preset is also permitted.
This parameter is without significance when using manufacturer-specific output formats 100 to 102.
Read:
This parameter reads the preset value.
Parameter 65000
Type Read / Write
Data type int32 (0x04)
Value range signed 32bit
Data: 65000 [0] Preset Value
Write
: This parameter is to write the preset value.
After the write operation by parameter 65000, the preset value is stored volatile.
Use parameter 971 for non-volatile saving in the encoder memory.
Parameter 65000
Type Read / Write
Data type int32 (0x04)
Value range signed 32bit
Data: 65000 [0] Preset Value