165
Add Defect Pixel to Defect Pixel List with Baumer Camera Explorer
Notice
The addition of defect pixels must be done in FullFrame (without
Binning
, without
Width
/
Height
/
OffsetX
/
OffsetY
), in raw data format and without activated color calculation.
1.
Start the
Camera Explorer
. Connect to the camera. Select the profile
GenICam
Guru
if necessary..
2.
Open the category
LUT
Control
.
3.
Locate an empty
Defect Pixel List Index
.
Defect Pixel List Entry PosX
= 0
Defect Pixel List Entry PosY
= 0
Avoid using existing coordinates!
4.
Determine the coordinates of the defect pixel. Keep the mouse pointer over the
defect pixel. The coordinates of the defect pixel is displayed in the status bar.
For simplification, you can enlarge the image.
5.
Enter the determined coordinates for X (
Defect Pixel List Entry PosX
) and Y
(
Defect Pixel List Entry PosY
).
6.
Activate the registered
Defect Pixel List Index
(
Defect Pixel List Entry Active =
True
).
7.
Stop the camera and start them again to take over the updated coordinates.
7.15.1 DefectPixelCorrection
Enable the correction of defect pixels.
Name
DefectPixelCorrection
Category
LUTControl
Interface
IBoolean
Access
Read / Write
Unit
-
Values
true = 1 (On)
false = 0 (Off)
7.15.2
DefectPixelListEntryActive
Determines if the pixel correction is active for the selected entry.
Name
DefectPixelListEntryActive
Category
LUTControl
Interface
IBoolean
Access
Read / Write
Unit
-
Values
true = 1 (On)
false = 0 (Off)