![Baumer 11188367 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/baumer/11188367/11188367_operating-manual_2710694020.webp)
Manual R600V.DAE0 (EN)
Page 20 of 29
R600V.DAE0_manual_1.5 (EN).docm
3.3 Supported PGN (Parameter Group Number)
3.3.1
ECU Identification Info
PGN:
0xFDC5
Direction:
Transmit
Transmission rate:
On PGN request only
3.3.2
ECU Software Identification
PGN:
0xFEDA
Direction:
Transmit
Transmission rate:
On PGN request only
3.3.3
DM14 Memory access command message
PGN:
0xD900
Direction:
Receive
Transmission rate:
Random
3.3.4
DM15 Memory access reply message
PGN:
0xD800
Direction:
Transmit
Transmission rate:
Reply to DM14 command message
3.3.5
DM16 Memory access binary data
PGN:
0xD700
Direction:
Transmit/receive
Transmission rate:
When needed
3.3.6
Ground & Canopy Message
PGN:
0xC000
Direction:
Transmit
Transmission rate:
50ms
Source address:
Sensor address
Destination address:
Broadcast (0xff)
Initial delay after start-up sequence:
200ms
All (data field) values are in little endian format. Bit1 of byte 1 = LSB of first byte