3.7  Trouble shooting 

General 

The sensors work in a 3-step pattern 
1.  Waiting for Start of Frame (SOF) 
2.  Waiting for address or timeout 
3.  Waiting for End of Frame or timeout 

 

Error conditions  
Error according to SOF when: 
 
1.  Time between 2 characters exceeds 0.5 s (Timeout) 
2.  Number of characters does not correspond with the command.  
3.  Unknown command 
4.  Command contains wrong parameters 
5.  Wrong address 

 

Error message 

The syntax of an error message is identical to a standard sensor response message  

N

a

m

e

 

C

o

m

m

a

n

d

  

 

S

y

n

ta

x

 

S

e

n

s

o

re

s

p

o

n

s

e

 

m

e

s

s

a

g

e

 

P

a

ra

m

e

te

 

C

o

m

m

e

n

  

Error  message  E 

Faulty 
command 

{0EXßß) 

F = Framing error = wrong string 
length 
T = after SOF or before EOF more 
than 0.5s distance between 2 
characters  
U = Unknown command 
P = impermissible parameter  
A = Wrong address  

Actions in case on an error:  

 

Sensor is emitting error message  

 

Sensor is waiting for SOF 

 

Output provided in case of a false measurement: measured value = 4095 (ASCII), BF 3F (binary) 

 

3.8  Examples 

Commands 

Sent  

Received 

Content  

Reset 

{0R} 

{0RV01000005} 

 

Set factory setting  

{0D} 

{0D16} 

 

Set measuring mode 

{0AB} 

{0AB79} 

Relative measurement 

Set output data format for 
permanent periodical data 
issue  

{0FA} 

{0FA83} 

Set to ASCII 

Set sensitivity 

{0BC} 

{0BC81} 

Second highest 
sensitivity 

Set number of averaging  

{0CC} 

{0CC82} 

4 averaging 

Temperature compensation 

{0G1} 

{0G168} 

Temperature comp. ON 

Содержание 09 Series

Страница 1: ... 2 2 Installation 2 2 1 Installation methods and installation suggestions 2 2 2 Mechanical cascading of a number of sensors 2 2 3 Beam columnator 3 2 4 Positioning above containers Sensors with beam columnator D1 3 3 The RS 232 interface 4 3 1 General notes 4 3 2 Structure of commands 4 3 3 Sensor configuration 5 3 4 Factory configurations 5 3 5 Commands 5 3 6 Commands explained in detail 8 3 7 Tr...

Страница 2: ...allation instruction sheet which is packed with every sensor shipped 2 Installation 2 1 Installation methods and installation suggestions 2 2 Mechanical cascading of a number of sensors In case of a number of sensors being installed side by side cascading they may not be screwed down directly touching each other This is due to the mechanical tolerances of the sensor housings and the possible dange...

Страница 3: ... Disassembling the beam columnator In order to prevent damage to either sensor or beam columnator always turn the beam columnator first turn before pulling it off Never attempt to snap the beam columnator from the sensor without turning it first 2 4 Positioning above containers Sensors with beam columnator D1 When measuring fill levels in micro titration plates or in similarly small containers it ...

Страница 4: ...ust be checked from time to time and cleaned if necessary Via the RS 232 interface measured data can be received and a number of functions are configurable The sensors work with a baud rate of 115 200 3 2 Structure of commands All commands consist of ASCII characters only One character consists of 1 start Bit 8 data Bits and 1 Stop Bit Address Address 0 is the broadcast address which is accepted b...

Страница 5: ...he functionality of the sensors as well as the output format of the data measured can be set by means of the configuration commands Once the configuration has been carried out the data measured can be retrieved It is provided according to the configuration set after every request for data sent The chosen configuration is stored in a non volatile memory and is not lost in a power down situation 3 4...

Страница 6: ...ring into test tubes Measuring range 3 150 mm B Second highest sensitivity Measuring into plates size 96 with big hole diameter Measuring range 3 110 mm C Second lowest sensitivity Measuring into plates size 96 with small hole diameter Measuring range 3 70 mm D Lowest sensitivity Measuring into plates size 384 Measuring range 3 30 mm See chapter Commands explained in detail Set number of averaging...

Страница 7: ...Number of averagings Temperature compensation on off P code SW document number SW version Identification 2 Byte See chapter Commands explained in detail Set configuration U 0U 0U ßß Configuration of sensor with a command Measuring mode absolute relative Output format Binary ASCII Sensor sensitivity Sensors with beam columnator Number of averagings Temperature compensation on off See chapter Comman...

Страница 8: ...des the value 0 In the case of no object being within the measuring range the output shows the value 4095 Binary format The binary format is only used for the permanent periodical data output in order to transmit the data measured with the maximum data rate For that reason the binary format is very compact with only a minimum of overhead First Byte Bit 7 is 1 Mark for start of data string Bit6 1 O...

Страница 9: ... has been applied When the temperature compensation is switched OFF the sensor measures immediately and correctly at room temperature Is the environmental temperature changing a measurement error of 0 18 Sde K occurs Format of the Get Configuration data output Measuring mode 1 Byte Output format 1 Byte Sensor sensitivity 1 Byte Sensors with beam columnator Number of averages 1 Byte Temperature com...

Страница 10: ... Command Syntax Sensor response message Parameter Comment Error message E Faulty command 0EXßß X F Framing error wrong string length T after SOF or before EOF more than 0 5s distance between 2 characters U Unknown command P impermissible parameter A Wrong address Actions in case on an error Sensor is emitting error message Sensor is waiting for SOF Output provided in case of a false measurement me...

Страница 11: ...on A absolute measurement B Binary for periodical measurement A lowest sensitivity F 32 averagings 0 temperature compensation OFF 47 Check sum Write 2 Byte Identification 0N01 0N0123 01 written to the sensor Read 2 Byte Identification 0O 0O0124 01 read from the sensor Single measurement 0M 0M11140121 1 Object within range 1 Echo width big 1401 measured value Start permanent periodical data output ...

Отзывы: