Operation in potentially explosive environments
2
2
Operation in potentially explosive environments
2.1
The device complies with the
directive 2014/34/EU
for potentionally explosive atmospheres.
It can be used in accordance with
equipment category 2 G
(explosive gas atmosphere).
Equipment category 2 G:
- Ex labeling:
II 2 G Ex db eb IIC T6 Gb
- Conforms to standard:
EN 60079-0:2012 + A11:2013
General defination
EN
60079-1:2014
Explosion
proof
enclosure
„d“
EN
60079-7:2015
Increased
safety
„e“
- Type of protection:
db eb
-
Temperature
class:
T6
- Group of equipment:
II
- Explosive gas group:
IIC
- Device protection level:
Gb
Operation in explosive atmospheres of category 3 G is also permissible. The operation in other
explosive atmospheres is not permissible.
EU type examination certificate on demand:
TÜV NORD CERT Nr. TÜV 03 ATEX 2201 X
2.2
In Ex areas
2 G
the device must only be used within the
ambient temperature range
from -20
°C to +55 °C.
2.3
Any
UL listing
that may be quoted in any other technical documentation does
not apply to use
in the Ex area
.
2.4
Operation of the device is only permissible when ...
–
the details on the type label of the device match the on-site conditions for the permissible
Ex area in use (group of equipment, equipment category, zone, temperature class or maxi-
mum surface temperature),
–
the details on the type label of the device match the electrical supply network,
–
the device is undamaged (no damage resulting from transport or storage), and
–
it has been checked that there is no explosive atmosphere, oils, acids, gases, vapors,
radiation etc. present when mounting.
2.5
It is not permissible to make any alteration to equipment that is used in potentially explosive en-
vironments.
Repairs
of explosion-protected equipment may only be carried out by the
manufac-
turer
.
Contravention invalidates the EX approval.
2.6
Attend the norm EN 60079-14 during mount and operation.
The device must be operated in accordance with the stipulations of the mounting and
operating instructions. The relevant laws, regulations and standards for the planned
application must be observed.