Gas adjustment (Conversion to LPG for the oven and grill)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Free the burners from their
fixing screws.
o
Unscrew the injectors and replace
them with the stipulated injector
for the new gas supply (see table
below).
Burner
Type
Gas Type
Pressure Injector
Marking
(1/100
mm)
Gas
consumption*
MAX
Power
(kW)
MIN
Power
(kW)
LPG G30/
G31
28…
30/37
98 305
g/h
Main
Oven
Natural
gas
G20 20
150
400
dm³/h
4.200
1.000
LPG G30/
G31
28…
30/37
88 240
g/h
Grill
Oven
Natural
gas
G20 20
136
314
dm³/h
3.300
N/A
*
In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
IMPORTANT: You must change the oven and grill injectors.