![Baumatic PCG9110SS Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/baumatic/pcg9110ss/pcg9110ss_instruction-manual_2709662029.webp)
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan-stands, burners and flame
spreaders
(A)
.
28
ow).
o
Unscrew the injector
(B)
and replace it with
the stipulated injector for the new gas supply
(see table bel
Burner
Type
Gas Type
Pressure
(mbar)
Injector
Marking
(1/100
mm)
Gas
Consumption*
MAX
Power
(kW)
MIN
Power
(kW)
Liquid
gas
G30/
G31
28…
30/37
52 73
g/h
Auxiliary
burner
(Ø55mm)
Natural
gas
G20 20
72 95
dm³/h
1.000
0.300
Liquid
gas
G30/
G31
28…
30/37
68 127
g/h
Semi-rapid
burner
(Ø75mm)
Natural
gas
G20 20
98 167
dm³/h
1.750
0.440
Liquid
gas
G30/
G31
28…
30/37
88 218
g/h
Rapid
burner
(Ø100mm)
Natural
gas
G20 20
116 286
dm³/h
3.000
0.750
LPG G30/G31
28…
30/37
96 262
g/h
Wok
burner
(Ø130mm)
Natural
gas
G20 20
135 343
dm³/h
3.600 1.500