o
Care should be taken to ensure that the temperature rise of
areas at the rear of the cooker that are likely to come in contact
with the flexible hose do not exceed 70°C.
o
Gas pressure may be checked on a semi-rapid hob burner.
Remove the appropriate injector and attach a test nipple. Light
the other burners and observe that the gas pressure complies
with the gas standards in force.
o
This cooker can be connected to the supply both on the right and
left hand side at the rear of the cooker. To reverse the position,
remove the blanking plug and refit it to the opposite side to
where the hose is being connected.
o
IMPORTANT: On completion carry out a gas tightness test.
Gas adjustment (Conversion to LPG)
All work must be carried out by a CORGI registered
engineer.
31
IMPORTAN
e
T: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting th
minimum flow of the burners.
o
Remove the pan-stands, burners and flame
spreaders (A).
o
Unscrew the injector (B) and replace it with
the stipulated injector for the new gas supply
(see table below).
Содержание PCC9120SS