Installation
The installation must be carried out by a GASSAFE
registered installer, in accordance with the current
version of the following.
o
Gas Safety Regulations (Installation & Use)
o
Building Regulations (issued by the Department of Environment)
o
Building Standards (Issued by the Scottish Development
Department)
o
IEE Wiring Regulations
o
Electricity at Work Regulations BS 6172
o
Installation of Domestic Gas Cooking Appliances (if necessary,
BS 5482 Installation of Domestic LPG Appliances)
o
BS 5440 Installation of Flues and Ventilation for Gas Appliances
o
Baumatic Ltd Installation Instructions
Positioning
The adjacent furniture must be able to withstand a
minimum temperature rise of 85°C above the ambient
temperature of the room it is located in, during
periods of use.
o
This appliance can be located in a kitchen, a kitchen diner or a
bed sitting room.
IMPORTANT:
The appliance must not be
installed in a bathroom or shower room.
This appliance is classified as Class 3 and therefore is to be built into a
kitchen unit (depending on size) or 600mm worktop, providing the
following minimum distances are allowed:
o
The edges of the hob must be a minimum distance of 55 mm
from a side or rear wall.
o
700 mm between the highest point of the hob surface (including
the burners) and the underside of any horizontal surface directly
above it.
o
400 mm between the hob surface, providing that the underside
of the horizontal surface is in line with the outer edge of the hob.
19
Содержание OMBRA6BL
Страница 1: ...1 el OMBRA6SS BL W R 75 cm Touch control gas hob...
Страница 30: ...30...
Страница 35: ...35...
Страница 36: ...36...