2. Electric connections 

 
Check the details given on the nameplate situated on the underside of the cook top, then make sure that the rated 
mains voltage and power available are suitable for its operation. 
Before making the electric connections, check the efficiency of the earthing system. Earthing of the cook top is 
compulsory by law. The manufacturer will accept no liability for any personal injury or damage to property deriving 
from failure to comply with this requirement. 
  
Use only rubber cable type H05RR-F; the cross-section of the wires must be 3x1.5 mm. 
 
DECLARATION OF CONFORMITY. In the parts destined to come into contact with foodstuffs, this appliance is in 
accordance with the requirements of the EC directive 89/109 transposed in the Italian Legislative Decree N° 108 of 
25/01/92. 
 

CE 

Appliance conforming to the European directives 90/396/CEE, 89/336/EEC, 93/68/EEC, 73/23/EEC and 

subsequent revisions.

 

 

 
Connection options 

 
 
 
 
 
 
 
 
 

CONNECTION (GAS PART)   
 
 

The gas supply must be connected by use of the ½ BSP Elbow, Seal, Regulator supplied (Natural Gas only) or 
Test Point Assembly supplied (LPG only) and copper pipe or flexible hose connection.  An isolation tap fitted in an 
easily accessible position is recommended. 
 
The nameplates on the gas cook tops state the type of gas to be used with the appliance. 
However other types of gas can be used after making a few minor modifications. 
(See the Instructions in Section titled ‘Adaptation to different Gas types’ on page 5.) 
 

Gas-supply connection  

The cook top must be connected to the gas mains or canister in accordance with Standards AS 5601, ensuring 
beforehand that it is regulated to suit the gas-supply. If it is not, follow the instructions in the “Adapting to different 
gas types” paragraph. If fed by a canister of liquid gas, use pressure regulators that are AGA Certified. 
Important: for safe operation, suitable use of energy and longer equipment life, ensure that the feeding pressure is 
within the values shown in the table (Burner Technical Details page 6 and the data label). 

 

Flexible Hose Assembly 

The appliance is suitable for connection with an AGA Approved, Class B or D Flexible Hose Assembly, which 
complies with AS/ANZ1869 and is 1200mm maximum length and 10mm minimum internal diameter. Ensure that 
the Hose does not contact the hot surfaces of the hotplate, oven, dishwasher or other appliance that may be 
installed underneath or next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent 
deformation and should be able to be inspected along its entire length. Unions compatible with the hose fittings 
must be used and connections tested for gas leaks. The supply connection point shall be accessible with the 
appliance installed. 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание BT66SS

Страница 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS BT66SS...

Страница 2: ...100 C and are between 25 and 40 mm thick If the cook top is installed in a position so that the side of a kitchen unit comes up against its left hand or right hand side the distance between the verti...

Страница 3: ...y keeping all the natural air vents open or by installing a kitchen hood with an outlet duct Intensive and prolonged cooker use may require additional ventilation for example opening a window or more...

Страница 4: ...e type of gas to be used with the appliance However other types of gas can be used after making a few minor modifications See the Instructions in Section titled Adaptation to different Gas types on pa...

Страница 5: ...k top to the gas mains by fitting the seal and fastening the mains pipe to the swivel coupling A1 Inlet pipe A2 Seal A3 Swivel coupling Only use pipes and seals that comply with AS5601 These pipes mus...

Страница 6: ...ppliance A duplicate label is supplied to adhere in an accessible area adjacent to the appliance This appliance is suitable for Natural Gas or Propane Gas ensure that the available gas supply matches...

Страница 7: ...rer will accept no liability for any damage caused by improper incorrect or irrational use Using the burners If the burners are not used for several days wait a few seconds before lighting them in ord...

Страница 8: ...alves which are difficult to turn In case the appliance fails to operate correctly contact the authorised Service Department Think Appliances on Phone 1800 444 357 WARNING Servicing should be carried...