o
Use a spanner to adjust the height of the adjustable feet.
o
If your aperture has a height of 820 mm, then the adjustable
feet should be set at a height of 30 mm.
o
If your aperture has a height of 870 mm, then the adjustable
feet should be set at a height of 50 mm.
o
The appliance should be flush with the underside of the worktop
and be level. IMPORTANT: If the appliance is not level, then the
door and door seal may be affected.
o
A cut out must be made in the plinth/kickboard for ventilation.
The cut out should measure 140 mm in width and 90 mm in
height.
o
Insert the plinth/kickboard and then refit the grid in its original
position to hold it in place.
o
IMPORTANT: Please note that as shown in the above
drawing, an appropriately sized ventilation cut MUST be
made in the furniture plinth/kickboard.
Fitting the furniture door to the appliance
If you need the appliance door to open from the other
side, then please reverse the door before commencing the
installation process. (See “Reversing the door” section).
Tools required:-
o
Tape measure
o
Sharp pencil
o
Small flat bladed screwdriver
o
Spanner