PRESSURE Ø
INJECTOR
THERMAL
CAPACITY
GAS TYPE
mbar
BURNER
1/100
mm
Nominal W
CONSUMPTION
Triple-
crown
141 3500
333
Rapid 129 3000 286
Semi-
rapid
101 1750
167
Natural
gas – G20
20
Auxiliary 77
1000 95
l/h
Triple-
crown
94 3500
254
Rapid 87 3000 218
Semi-
rapid
66 1750
127
LPG –
G30/G31
28-30/37
Auxiliary 50
1000 73
g/h
o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o
IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Switch the burner on and set the knob at the minimum position.
o
Remove the knob from the tap and place a small bladed
screwdriver in the centre of the tap shaft.
26
Содержание BHG300.5SS
Страница 1: ...1 User Manual for the BHG300 5SS BHG604 5SS W BHG610 5SS BHG710 5SS BHG900 5SS GAS HOB ...
Страница 31: ...31 ...
Страница 33: ...33 ...
Страница 34: ...34 ...
Страница 35: ...35 ...
Страница 36: ...cod 1 008 89 0 www baumatic co uk ...